Describe the bug
After #5428, I compiled the newest ABACUS with nothing different than before, except for cloning LibRI and LibComm and manually set their directories. However, all the EXX cases I've tried to run with multiple processors failed:
---------------------------------------------------------
Initial plane wave basis and FFT box
---------------------------------------------------------
DONE(0.0504186 SEC) : INIT PLANEWAVE
Abort(470409475) on node 0 (rank 0 in comm 0): Fatal error in internal_Isend: Unknown error class, error stack:
internal_Isend(30152): MPI_Isend(buf=0x7f3840001a80, count=11144, INVALID DATATYPE, 1, 0, MPI_COMM_WORLD, request=0x3e07474) failed
internal_Isend(30098): Invalid datatype
No such error if I reset LibComm's commit from 55ea39ed2916f31335c3ed469619505aa716c92a to 6975a5f50ebed7ab9b5a3eee35a8324a97833c44.