Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy pathpowersavemode.py
More file actions
executable file
·176 lines (151 loc) · 8.31 KB
/
powersavemode.py
File metadata and controls
executable file
·176 lines (151 loc) · 8.31 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
# ---------- DESCRIPTION ----------------
#
# This program estimates the remaining available power to be used by the heating system.
#
# Two algorithm modes are available G or I
# General: based on overall house energy consumtion
# Individual: based on non heating energy consumtion
#
# It monitors
# - The various meeter available in the house
# GENERAL_METER define the unique overall installation meeter
# EXTRA_METERS list the meeter attached to large non heater item
# It controls a power_saving_mode
# The power_saving_mode is a HA numeric variable that is monitored as entry
# by load power balancing script roundrobin.py
# Caculation can be done with Ampere (A) or Watts (W) or kW
# You just need to be consistant and always used the same unit.
#-------------- LICENSE ---------------
# Apache V2 http://www.apache.org/licenses/
#------------- CONSTRAINT -------------
# Trip are fast and your code must react faster than the trip
# You rarelay have more than 1 or 2 seconds to correct power use before backout.
# Meters reporting value less than once a second for such use case are useless.
# ---------- CONFIGURATION ---------------
# Configuration is specific to each house and MUST be aligned with reality
#
# All CONSTANT must be declared in respect of Python3 syntax.
# Errors will only be reported in home-assistant.log
#---------- Energy unit ---------
# The code algorithm does not change whatever is your reference unit (A/W/kW your call)
# but it must be the same for all values
# For info my config work with A, hence the default value in the code
# TEST_MODE = True the actual control the radiator is deactivated
# but reports and log remains as normal
# for normal operation TEST_MODE = False
TEST_MODE = False
# Numeric HA state variable receiving the estimated power saving index.
# Note: the actual number of active radiator is defined in roundrobin.py
# Number of possible mode must be the same in HA, roundrobin.py and here.
POWER_SAVING_MODE='input_number.powsersavingmode'
# Time in second before we accept to decrease the power_saving_mode.
# If this time is too short, the power saving mode goes down quicker than the radiators
# are switched on and will always reach 0 to then go up again.
# It just a protection to limit relay wearing.
DAMPING_DELAY=90
# Maximum availaible power in the house (same unit as POWER_PER_RADIATOR)
MAX_AVAILABLE_HOUSE_POWER=30
# Select the type of algorith used fo rthe estimation
# ESTIMATION_MODE='G' The remaining power available for heating is estimated using
# the number of active radiator
# That mode only required 1 meter (GENERAL_METER)
# ESTIMATION_MODE='I' The remaining power available for heating is estimated using
# the actual power used by not heating equipement
# It requires additional meter(s) (a list of list)
# NON_HEATING_METERS (house non heating energy use)
ESTIMATION_MODE='G'
# Estimated max energy consumtion per radiator
POWER_PER_RADIATOR=5
# Entity measuring the over power used by the house (same unit as POWER_PER_RADIATOR)
# you can use a template to report the meter reading in the right unit.
# The second paramater is a conversion ratio to get all reading on the same unit.
# e.g. is reading is mA using 1000 would convert it in A
# kW 0.001 would convert it in W
# Format ('meter_entity','attribute', unit_convertion_ratio)
# if 'attribute' is empty data is read from entity status
GENERAL_METER=('sensor.enedis_amp','',1)
# This code is triggered each time that the house power consumsion changes which means often
# HYSTERIS_FACTOR is design to smooth down the decrease of power_saving_mode
# while leaving a fast reaction when power_saving_mode needs to be increased.
HYSTERESIS_FACTOR=1.2
# Due to embedded thermostat we cannot know if a radiator draw power when it's 'on'
# We can only guess a factor to cover that risk
# Higher accuracy requires higher target temperature on the embbeded thermostat
# Schedule starting many radiator change at the same time will reduce accuracy
SAFE_RATIO=1.3
#------- required for ESTIMATION_MODE == 'I' ----------
# list of list of on or several meter(s) reading all significant non heating equipement
# Note: MUST remain a list of list even with only one meter defined
# The first parameter is the name of entity provinding the meter reading
# The second is a conversion ratio to get all reading on the same unit.
# The reading value must be in the variable state and it expected to be a string representing a float.
# Would the reading be in an attribute a template should created externally.
# Format (('meter_entity', 'attribute', unit_convertion_ratio),(...))
# if 'attribute' is empty data is read from entity status
NON_HEATING_METERS=(('sensor.washing_machine_rms_current','',1000), ('sensor.dish_washer_rms_current','',1000))
# Security margin to cover energy requirement not measured by EXTRA_METERS
SECURITY_MARGIN=3
#---------- IMPORT ----------
import time
#---------STATE VARIABLE ---------
# data required between triggers
# EPOC unix time in second
# heating_remaining_power is provided for potential external application or autoamation
state.set(
'pyscript.powerstate_status',
value='none',
new_attributes={
'heating_remaining_power' : 0,
'time_last_decrease': int(time.time())
})
#--------- IMPORTED DATA --------
ACTIVE_RADIATORS='pyscript.radiator_status.radiator_live_mode'
log.info(f"powersavingmode.py: Imported data from roudrobin.py successful -> starting monitoring")
# extracting meter data
def read_data(sensor):
reading=float(0)
if sensor[1] == '':
# data is directlty in state variable status
reading=float(state.get(sensor[0]))
else:
# data is in an attribute
reading=float(state.getattr(sensor[0],sensor[1]))
return(reading/sensor[2])
# Adding all sensors reading only needed when ESTIMATION=='I'
def add_data(meters_list):
data=float(0)
for i in meters_list:
data=data+read_data(i)
return(data)
#--------- TRIGGER --------------
#
# Trigger each time general meeter value changes
@state_trigger(GENERAL_METER[0]+GENERAL_METER[1])
def power_meter_new_reading (value):
# new trigger arrive before end of processing the previous one, the ignore previous value
task.unique("power meeter_changed_value", kill_me=False)
log.info(f"powersavingmode.py: General power meter new_value={value}")
estimate_power_saving_mode()
# Estimation of a new per saving mode
def estimate_power_saving_mode():
if ESTIMATION_MODE=='G':
heating_remaining_power=MAX_AVAILABLE_HOUSE_POWER-read_data(GENERAL_METER)+ACTIVE_RADIATORS.count('1')*POWER_PER_RADIATOR/SAFE_RATIO
else:
heating_remaining_power=MAX_AVAILABLE_HOUSE_POWER-add_data(NON_HEATING_METERS)-SECURITY_MARGIN
log.debug(f"powersavingmode.py: estimated available power={heating_remaining_power:2.2f}")
state.setattr('pyscript.powerstate_status.heating_remaining_power',heating_remaining_power)
# power_saving_mode=0 indicates max power available for the heating system.
# when available power is reducing, we need to be quick to increase the saving_power_mode
if heating_remaining_power < POWER_PER_RADIATOR*SAFE_RATIO and not TEST_MODE:
log.debug(f"powersavingmode.py: saving_power_mode +1")
service.call('input_number','increment',blocking=False, entity_id=POWER_SAVING_MODE)
# hysteresis is created when available power increases to reduce wear on electromagnetic relays.
if heating_remaining_power > POWER_PER_RADIATOR*SAFE_RATIO*HYSTERESIS_FACTOR and not TEST_MODE:
# We want to slow down powersavingmode decrease
if int(time.time()) > int(pyscript.powerstate_status.time_last_decrease)+DAMPING_DELAY:
log.debug(f"powersavingmode.py: saving_power_mode -1 time {int(time.time())} , {int(pyscript.powerstate_status.time_last_decrease)+DAMPING_DELAY}")
state.setattr('pyscript.powerstate_status.time_last_decrease', int(time.time()))
service.call('input_number','decrement',blocking=False, entity_id=POWER_SAVING_MODE)
# debug only
log.debug(f"powersavingmode.py: saving_power_mode ={state.get(POWER_SAVING_MODE)}")
log.debug(f"powersavingmode.py: general_meter_reading ={read_data(GENERAL_METER):2.2f}")