Hey,
I encountered a strange behavior in my setup for the second time now. After homebridge-hue lost connection to the Hue bridge (v2, latest update), in the case of today, because of a scheduled Hue bridge update, all of my dimmer switches get pressed once "magically" over the next minutes after homebridge-hue reconnected to the Hue bridge. When this first appeared a couple of weeks ago it freaked me out a bit, because I thought somebody hacked my system. I changed all passwords and checked if any system was breached. I found nothing. I disconnected the Hue bridge from the hue.com online service, so that also all hue components are only online via Homekit. It didn't help. The problem reoccurred tonight.
To be a bit more precise what you can also see in the logs:
- Homebridge-hue loses connection to the Hue bridge (4:56:07 AM)
- After it reconnected (4:57:24 AM), everything seems fine, but as you can see at 5:01:27 AM, 5:03:31 AM and 5:09:40 AM for every Hue dimmer switch one button is "magically" pressed while I was asleep ("homekit button single press"). There was no human interaction with these switches at all! There are also no automations regarding these switches in Homekit at a all.
- What I also can't explain is the "hostname: homebridge: Host not found" right after 5:05:16 AM. Maybe this has something to do with it?
I would appreciate any feedback on what can cause that issue. If my setup is wrong, or if it's a bug.
And thanks again for you amazing work!
Best regards,
Adrian
Log Messages
[37m[5/11/2022, 4:53:07 AM] [39m[36m[Hue][39m Hue temperature sensor 1: set homekit temperature from 21.8°C to 21.9°C
[37m[5/11/2022, 4:54:46 AM] [39m[36m[Hue][39m Hue temperature sensor 2: set homekit temperature from 22°C to 22.2°C
[37m[5/11/2022, 4:56:04 AM] [39m[36m[Hue][39m Büro Multisensor: set homekit humidity from 52% to 53%
[37m[5/11/2022, 4:56:04 AM] [39m[36m[Hue][39m Büro Multisensor: set homekit pressure from 1008 hPa to 1007 hPa
[37m[5/11/2022, 4:56:07 AM] [39m[36m[Hue][39m Hue Bridge: request 1752930: GET /sensors
[37m[5/11/2022, 4:56:07 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752930: http status 502 Bad Gateway[39m
[37m[5/11/2022, 4:56:07 AM] [39m[36m[Hue][39m [33mHue Bridge: event stream connection to https://192.168.178.31/eventstream/clip/v2 closed - retrying in 15s[39m
[37m[5/11/2022, 4:56:08 AM] [39m[36m[Hue][39m Hue Bridge: request 1752931: GET /sensors
[37m[5/11/2022, 4:56:08 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752931: connect ECONNREFUSED 192.168.178.31:443[39m
[37m[5/11/2022, 4:56:15 AM] [39m[36m[Hue][39m Hue Bridge: request 1752932: GET /sensors
[37m[5/11/2022, 4:56:15 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752932: timeout after 5 seconds[39m
[37m[5/11/2022, 4:56:17 AM] [39m[36m[Hue][39m Hue Bridge: request 1752933: GET /sensors
[37m[5/11/2022, 4:56:17 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752933: timeout after 5 seconds[39m
[37m[5/11/2022, 4:56:19 AM] [39m[36m[Hue][39m Hue Bridge: request 1752934: GET /sensors
[37m[5/11/2022, 4:56:19 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752934: timeout after 5 seconds[39m
[37m[5/11/2022, 4:56:21 AM] [39m[36m[Hue][39m Hue Bridge: request 1752935: GET /sensors
[37m[5/11/2022, 4:56:21 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752935: timeout after 5 seconds[39m
[37m[5/11/2022, 4:56:23 AM] [39m[36m[Hue][39m Hue Bridge: request 1752936: GET /sensors
[37m[5/11/2022, 4:56:23 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752936: timeout after 5 seconds[39m
[37m[5/11/2022, 4:56:25 AM] [39m[36m[Hue][39m Hue Bridge: request 1752937: GET /sensors
[37m[5/11/2022, 4:56:25 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752937: timeout after 5 seconds[39m
[37m[5/11/2022, 4:56:27 AM] [39m[36m[Hue][39m Hue Bridge: request 1752938: GET /sensors
[37m[5/11/2022, 4:56:27 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752938: timeout after 5 seconds[39m
[37m[5/11/2022, 4:56:29 AM] [39m[36m[Hue][39m Hue Bridge: request 1752939: GET /sensors
[37m[5/11/2022, 4:56:29 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752939: timeout after 5 seconds[39m
[37m[5/11/2022, 4:56:31 AM] [39m[36m[Hue][39m Hue Bridge: request 1752940: GET /sensors
[37m[5/11/2022, 4:56:31 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752940: timeout after 5 seconds[39m
[37m[5/11/2022, 4:56:33 AM] [39m[36m[Hue][39m Hue Bridge: request 1752941: GET /sensors
[37m[5/11/2022, 4:56:33 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752941: timeout after 5 seconds[39m
[37m[5/11/2022, 4:56:35 AM] [39m[36m[Hue][39m Hue Bridge: request 1752942: GET /sensors
[37m[5/11/2022, 4:56:35 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752942: timeout after 5 seconds[39m
[37m[5/11/2022, 4:56:37 AM] [39m[36m[Hue][39m Hue Bridge: request 1752943: GET /sensors
[37m[5/11/2022, 4:56:37 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752943: timeout after 5 seconds[39m
[37m[5/11/2022, 4:56:39 AM] [39m[36m[Hue][39m Hue Bridge: request 1752944: GET /sensors
[37m[5/11/2022, 4:56:39 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752944: timeout after 5 seconds[39m
[37m[5/11/2022, 4:56:41 AM] [39m[36m[Hue][39m Hue Bridge: request 1752945: GET /sensors
[37m[5/11/2022, 4:56:41 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752945: timeout after 5 seconds[39m
[37m[5/11/2022, 4:56:42 AM] [39m[36m[Hue][39m Flur Multisensor: set homekit pressure from 1007 hPa to 1008 hPa
[37m[5/11/2022, 4:56:43 AM] [39m[36m[Hue][39m Hue Bridge: request 1752946: GET /sensors
[37m[5/11/2022, 4:56:43 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752946: timeout after 5 seconds[39m
[37m[5/11/2022, 4:56:44 AM] [39m[36m[Hue][39m Hue Bridge: request 1752949: GET /sensors
[37m[5/11/2022, 4:56:44 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752949: connect ECONNREFUSED 192.168.178.31:443[39m
[37m[5/11/2022, 4:56:45 AM] [39m[36m[Hue][39m Hue Bridge: request 1752947: GET /sensors
[37m[5/11/2022, 4:56:45 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752947: timeout after 5 seconds[39m
[37m[5/11/2022, 4:56:45 AM] [39m[36m[Hue][39m Hue Bridge: request 1752948: GET /sensors
[37m[5/11/2022, 4:56:45 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752948: connect ECONNREFUSED 192.168.178.31:443[39m
[37m[5/11/2022, 4:56:46 AM] [39m[36m[Hue][39m Hue Bridge: request 1752950: GET /sensors
[37m[5/11/2022, 4:56:46 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752950: connect ECONNREFUSED 192.168.178.31:443[39m
[37m[5/11/2022, 4:56:48 AM] [39m[36m[Hue][39m Hue Bridge: request 1752951: GET /sensors
[37m[5/11/2022, 4:56:48 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752951: connect ECONNREFUSED 192.168.178.31:443[39m
[37m[5/11/2022, 4:56:50 AM] [39m[36m[Hue][39m Hue Bridge: request 1752952: GET /sensors
[37m[5/11/2022, 4:56:50 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752952: connect ECONNREFUSED 192.168.178.31:443[39m
[37m[5/11/2022, 4:56:52 AM] [39m[36m[Hue][39m Hue Bridge: request 1752953: GET /sensors
[37m[5/11/2022, 4:56:52 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752953: connect ECONNREFUSED 192.168.178.31:443[39m
[37m[5/11/2022, 4:56:53 AM] [39m[36m[Hue][39m Hue Bridge: event stream request 3: GET /eventstream/clip/v2
[37m[5/11/2022, 4:56:53 AM] [39m[36m[Hue][39m [33mHue Bridge: event stream request 3: connect ECONNREFUSED 192.168.178.31:443[39m
[37m[5/11/2022, 4:56:54 AM] [39m[36m[Hue][39m Hue Bridge: request 1752954: GET /sensors
[37m[5/11/2022, 4:56:54 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752954: connect ECONNREFUSED 192.168.178.31:443[39m
[37m[5/11/2022, 4:56:56 AM] [39m[36m[Hue][39m Hue Bridge: request 1752955: GET /sensors
[37m[5/11/2022, 4:56:56 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752955: connect ECONNREFUSED 192.168.178.31:443[39m
[37m[5/11/2022, 4:56:58 AM] [39m[36m[Hue][39m Hue Bridge: request 1752956: GET /sensors
[37m[5/11/2022, 4:56:58 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752956: connect ECONNREFUSED 192.168.178.31:443[39m
[37m[5/11/2022, 4:57:00 AM] [39m[36m[Hue][39m Hue Bridge: request 1752957: GET /sensors
[37m[5/11/2022, 4:57:00 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752957: connect ECONNREFUSED 192.168.178.31:443[39m
[37m[5/11/2022, 4:57:02 AM] [39m[36m[Hue][39m Hue Bridge: request 1752958: GET /sensors
[37m[5/11/2022, 4:57:02 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752958: connect ECONNREFUSED 192.168.178.31:443[39m
[37m[5/11/2022, 4:57:04 AM] [39m[36m[Hue][39m Hue Bridge: request 1752959: GET /sensors
[37m[5/11/2022, 4:57:04 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752959: connect ECONNREFUSED 192.168.178.31:443[39m
[37m[5/11/2022, 4:57:06 AM] [39m[36m[Hue][39m Hue Bridge: request 1752960: GET /sensors
[37m[5/11/2022, 4:57:06 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752960: connect ECONNREFUSED 192.168.178.31:443[39m
[37m[5/11/2022, 4:57:08 AM] [39m[36m[Hue][39m Hue Bridge: event stream request 4: GET /eventstream/clip/v2
[37m[5/11/2022, 4:57:08 AM] [39m[36m[Hue][39m [33mHue Bridge: event stream request 4: connect ECONNREFUSED 192.168.178.31:443[39m
[37m[5/11/2022, 4:57:08 AM] [39m[36m[Hue][39m Hue Bridge: request 1752961: GET /sensors
[37m[5/11/2022, 4:57:08 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752961: connect ECONNREFUSED 192.168.178.31:443[39m
[37m[5/11/2022, 4:57:10 AM] [39m[36m[Hue][39m Hue Bridge: request 1752962: GET /sensors
[37m[5/11/2022, 4:57:10 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752962: connect ECONNREFUSED 192.168.178.31:443[39m
[37m[5/11/2022, 4:57:12 AM] [39m[36m[Hue][39m Hue Bridge: request 1752963: GET /sensors
[37m[5/11/2022, 4:57:12 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752963: connect ECONNREFUSED 192.168.178.31:443[39m
[37m[5/11/2022, 4:57:14 AM] [39m[36m[Hue][39m Hue Bridge: request 1752964: GET /sensors
[37m[5/11/2022, 4:57:14 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752964: connect ECONNREFUSED 192.168.178.31:443[39m
[37m[5/11/2022, 4:57:16 AM] [39m[36m[Hue][39m Hue Bridge: request 1752965: GET /sensors
[37m[5/11/2022, 4:57:16 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752965: connect ECONNREFUSED 192.168.178.31:443[39m
[37m[5/11/2022, 4:57:18 AM] [39m[36m[Hue][39m Hue Bridge: request 1752966: GET /sensors
[37m[5/11/2022, 4:57:18 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752966: connect ECONNREFUSED 192.168.178.31:443[39m
[37m[5/11/2022, 4:57:20 AM] [39m[36m[Hue][39m Hue Bridge: request 1752967: GET /sensors
[37m[5/11/2022, 4:57:20 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752967: connect ECONNREFUSED 192.168.178.31:443[39m
[37m[5/11/2022, 4:57:22 AM] [39m[36m[Hue][39m Hue Bridge: request 1752968: GET /sensors
[37m[5/11/2022, 4:57:22 AM] [39m[36m[Hue][39m [33mHue Bridge: request 1752968: connect ECONNREFUSED 192.168.178.31:443[39m
[37m[5/11/2022, 4:57:24 AM] [39m[36m[Hue][39m Hue Bridge: event stream connected to https://192.168.178.31/eventstream/clip/v2
[37m[5/11/2022, 4:58:07 AM] [39m[36m[Hue][39m Hue temperature sensor 1: set homekit temperature from 21.9°C to 21.8°C
[37m[5/11/2022, 4:58:08 AM] [39m[36m[Hue][39m Badezimmer Sensor: set homekit status fault from 0 to 1
[37m[5/11/2022, 4:58:08 AM] [39m[36m[Hue][39m Hue temperature sensor 4: set homekit status fault from 0 to 1
[37m[5/11/2022, 4:58:08 AM] [39m[36m[Hue][39m Hue ambient light sensor 4: set homekit status fault from 0 to 1
[37m[5/11/2022, 4:58:17 AM] [39m[36m[Hue][39m Badezimmer Sensor: set homekit status fault from 1 to 0
[37m[5/11/2022, 4:58:18 AM] [39m[36m[Hue][39m Hue temperature sensor 4: set homekit status fault from 1 to 0
[37m[5/11/2022, 4:58:18 AM] [39m[36m[Hue][39m Hue ambient light sensor 4: set homekit status fault from 1 to 0
[37m[5/11/2022, 4:58:52 AM] [39m[36m[Hue][39m Wohnzimmer Schalter: set homekit battery level from 86% to 76%
[37m[5/11/2022, 4:59:17 AM] [39m[36m[Hue][39m Kleines Bad Multisensor: set homekit pressure from 1007 hPa to 1006 hPa
[37m[5/11/2022, 5:00:22 AM] [39m[36m[Hue][39m Wohnzimmer Schalter: set homekit status fault from 0 to 1
[37m[5/11/2022, 5:01:27 AM] [39m[36m[Hue][39m Saugbert Schalter Dim Down: homekit button single press
[37m[5/11/2022, 5:01:27 AM] [39m[36m[Saugbert][39m INF getPauseState | roborock.vacuum.s5 | Pause possible is false
[37m[5/11/2022, 5:01:32 AM] [39m[36m[Hue][39m Hue temperature sensor 4: set homekit temperature from 22.1°C to 21.8°C
[37m[5/11/2022, 5:03:06 AM] [39m[36m[Hue][39m Hue temperature sensor 1: set homekit temperature from 21.8°C to 21.7°C
[37m[5/11/2022, 5:03:31 AM] [39m[36m[Hue][39m Alarmanlage Schalter On: homekit button single press
[37m[5/11/2022, 5:03:31 AM] [39m[36m[Alarm][39m Target mode (Away)
[37m[5/11/2022, 5:03:34 AM] [39m[36m[Alarm][39m Webhook event (Sent)
[37m[5/11/2022, 5:03:51 AM] [39m[36m[Alarm][39m Current mode (Away)
[37m[5/11/2022, 5:03:53 AM] [39m[36m[Alarm][39m Webhook event (Sent)
[37m[5/11/2022, 5:04:15 AM] [39m[36m[Hue][39m Hue temperature sensor 5: set homekit temperature from 21.7°C to 21.6°C
[37m[5/11/2022, 5:04:55 AM] [39m[36m[Hue][39m Badezimmer Multisensor: set homekit pressure from 1007 hPa to 1006 hPa
[37m[5/11/2022, 5:05:16 AM] [39m[36m[Hue][39m Wohnzimmer Multisensor: set homekit temperature from 23.8°C to 23.9°C
[37m[5/11/2022, 5:05:16 AM] [39m[36m[Hue][39m Flur Multisensor: set homekit pressure from 1008 hPa to 1007 hPa
hostname: homebridge: Host not found
[37m[5/11/2022, 5:05:31 AM] [39m[36m[Hue][39m Küche Multisensor: set homekit pressure from 1008 hPa to 1007 hPa
[37m[5/11/2022, 5:07:38 AM] [39m[36m[Hue][39m Wohnzimmer Multisensor: set homekit temperature from 23.9°C to 23.8°C
[37m[5/11/2022, 5:09:40 AM] [39m[36m[Hue][39m Büro Schalter Off: homekit button single press
[37m[5/11/2022, 5:09:44 AM] [39m[36m[Hue][39m Hue temperature sensor 2: set homekit temperature from 22.2°C to 22°C
[37m[5/11/2022, 5:11:31 AM] [39m[36m[Hue][39m Hue temperature sensor 4: set homekit temperature from 21.8°C to 22°C