Skip to content

Commit 7fc1cd5

Browse files
committed
tig welder: risk assessment
originally by mwalters, adapted from wiki.ehlab.uk/tigwelder_riskassessment Closes #50
1 parent 9554f90 commit 7fc1cd5

File tree

1 file changed

+141
-0
lines changed

1 file changed

+141
-0
lines changed
Lines changed: 141 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -0,0 +1,141 @@
1+
# TIG Welder
2+
3+
## Fire
4+
5+
### Severity
6+
7+
H
8+
9+
### Likelihood
10+
11+
L
12+
13+
### Risk rating
14+
15+
M
16+
17+
### Who may be harmed & how
18+
19+
The space, and any users in it
20+
21+
### Control measures
22+
23+
- Users must clear the area of flammable materials before any welding takes place
24+
- Metal welding table installed, walls/conduits shielded
25+
- Fire extinguisher installed in the welding area
26+
27+
## Fumes
28+
29+
### Severity
30+
31+
M
32+
33+
### Likelihood
34+
35+
M
36+
37+
### Risk rating
38+
39+
M
40+
41+
### Who may be harmed & how
42+
43+
Users, and other people in the room may breathe harmful fumes from the welding process.
44+
45+
### Control measures
46+
47+
- Users trained to prep and clean their workpieces, reducing fumes.
48+
- Large extractor fan installed beside the welding area and is capable of cycling the room air once every 70 seconds
49+
50+
## Gas bottle falling over
51+
52+
### Severity
53+
54+
M
55+
56+
### Likelihood
57+
58+
L
59+
60+
### Risk rating
61+
62+
M
63+
64+
### Who may be harmed & how
65+
66+
Any person nearby. If the valve were damaged, cylinder could become a projectile.
67+
68+
### Control measures
69+
70+
- Only cylinders that have been inspected for safety and come from a reputable supplier can be used.
71+
- Gas bottle should be chained to wall, out of the way
72+
73+
## Burns from hot objects
74+
75+
### Severity
76+
77+
M
78+
79+
### Likelihood
80+
81+
M
82+
83+
### Risk rating
84+
85+
M
86+
87+
### Who may be harmed & how
88+
89+
User, and possibly others nearby, may suffer burns from handling hot objects.
90+
91+
### Control measures
92+
93+
- Users trained to use appropriate tools and PPE, and to leave the area safe for other users
94+
- Signage installed to remind others there may be hot objects left there
95+
96+
## Oxygen depletion from compressed gas release
97+
98+
### Severity
99+
100+
H
101+
102+
### Likelihood
103+
104+
L
105+
106+
### Risk rating
107+
108+
M
109+
110+
### Who may be harmed & how
111+
112+
Any person in the room may suffer from asphyxiation.
113+
114+
### Control measures
115+
116+
- Amount of gas in the room is limited to ensure oxygen levels remain safe, even after accidental release.
117+
- Ventilation installed
118+
- Appropriately sized gas cylinders to be used - see wiki.ehlab.uk/tigwelder:oxygen
119+
120+
## UV Radiation Exposure
121+
122+
### Severity
123+
124+
M
125+
126+
### Likelihood
127+
128+
L
129+
130+
### Risk rating
131+
132+
M
133+
134+
### Who may be harmed & how
135+
136+
User and other persons nearby may suffer eye/skin damage.
137+
138+
### Control measures
139+
140+
- Users trained to use appropriate PPE
141+
- Welding curtain installed, users trained to use it.

0 commit comments

Comments
 (0)