wrong config_data created in iot_hdc2010_set_reset_and_drdy 7 bit have to be config->soft_res acording to 7.6.15 Reset and DRDY/INT Configuration Register

wrong config_data  created in `iot_hdc2010_set_reset_and_drdy` 7 bit have to be `config->soft_res` acording to 7.6.15 Reset and DRDY/INT Configuration Register
@CLAassistant
Copy link

CLA assistant check
Thank you for your submission! We really appreciate it. Like many open source projects, we ask that you sign our Contributor License Agreement before we can accept your contribution.
You have signed the CLA already but the status is still pending? Let us recheck it.

@github-actions github-actions bot changed the title Fixed wrong config in reset_and_drdy. Fixed wrong config in reset_and_drdy. (AEGHB-365) Aug 30, 2023
@YanKE01
Copy link
Contributor

YanKE01 commented Dec 11, 2024

hi @FriendOrYes . According to the HDC2010 datasheet, the seventh bit was indeed filled in incorrectly. To speed up the merging process, you need to synchronize with the latest master branch.

@YanKE01
Copy link
Contributor

YanKE01 commented Dec 12, 2024

The changes have been merged into the latest driver.