Skip to content

Commit 33b25e0

Browse files
committed
Templates update for nightly evcc-io/evcc@346c162
1 parent b5ac1c7 commit 33b25e0

File tree

4 files changed

+16
-24
lines changed

4 files changed

+16
-24
lines changed

templates/nightly/de/charger/keba-kecontact-p40-pro.yaml

Lines changed: 4 additions & 6 deletions
Original file line numberDiff line numberDiff line change
@@ -1,16 +1,14 @@
1-
template: keba-modbus
1+
template: keba-modbus-p40
22
product:
33
identifier: keba-kecontact-p40-pro
44
brand: KEBA
55
description: KeContact P40 Pro
6-
capabilities: ["1p3p", "mA", "rfid"]
6+
capabilities: ["mA", "rfid"]
77
requirements: ["sponsorship"]
8-
description: |
9-
Erfordert Firmwareversion 3.10.42 (C-series) bzw. 1.11 (X-series). Zur Phasenumschaltung wird zusätzlich der Keba Phasenumschalter (KeContact S10) benötigt und in den Wallboxeinstellungen muss die Umschaltsteuerung per Modbus aktiviert werden. Bei der x-Serie im WebMenü, bei der C-Serie per Modbus durch setzen des Wertes "3" im Register 5050.
108
render:
119
- default: |
1210
type: template
13-
template: keba-modbus
11+
template: keba-modbus-p40
1412
1513
# Modbus TCP
1614
modbus: tcpip
@@ -19,7 +17,7 @@ render:
1917
port: 502 # Port
2018
advanced: |
2119
type: template
22-
template: keba-modbus
20+
template: keba-modbus-p40
2321
2422
# Modbus TCP
2523
modbus: tcpip

templates/nightly/de/charger/keba-kecontact-p40.yaml

Lines changed: 4 additions & 6 deletions
Original file line numberDiff line numberDiff line change
@@ -1,16 +1,14 @@
1-
template: keba-modbus
1+
template: keba-modbus-p40
22
product:
33
identifier: keba-kecontact-p40
44
brand: KEBA
55
description: KeContact P40
6-
capabilities: ["1p3p", "mA", "rfid"]
6+
capabilities: ["mA", "rfid"]
77
requirements: ["sponsorship"]
8-
description: |
9-
Erfordert Firmwareversion 3.10.42 (C-series) bzw. 1.11 (X-series). Zur Phasenumschaltung wird zusätzlich der Keba Phasenumschalter (KeContact S10) benötigt und in den Wallboxeinstellungen muss die Umschaltsteuerung per Modbus aktiviert werden. Bei der x-Serie im WebMenü, bei der C-Serie per Modbus durch setzen des Wertes "3" im Register 5050.
108
render:
119
- default: |
1210
type: template
13-
template: keba-modbus
11+
template: keba-modbus-p40
1412
1513
# Modbus TCP
1614
modbus: tcpip
@@ -19,7 +17,7 @@ render:
1917
port: 502 # Port
2018
advanced: |
2119
type: template
22-
template: keba-modbus
20+
template: keba-modbus-p40
2321
2422
# Modbus TCP
2523
modbus: tcpip

templates/nightly/en/charger/keba-kecontact-p40-pro.yaml

Lines changed: 4 additions & 6 deletions
Original file line numberDiff line numberDiff line change
@@ -1,16 +1,14 @@
1-
template: keba-modbus
1+
template: keba-modbus-p40
22
product:
33
identifier: keba-kecontact-p40-pro
44
brand: KEBA
55
description: KeContact P40 Pro
6-
capabilities: ["1p3p", "mA", "rfid"]
6+
capabilities: ["mA", "rfid"]
77
requirements: ["sponsorship"]
8-
description: |
9-
Requires firmware version 3.10.42 (C-series) bzw. 1.11 (X-series). For phase switching the Keba phase switch (KeContact S10) is also required and the switching control via Modbus must be set in the wallbox settings. For the X-series in the web menu, for the C-series via Modbus by setting the value "3" in register 5050.
108
render:
119
- default: |
1210
type: template
13-
template: keba-modbus
11+
template: keba-modbus-p40
1412
1513
# Modbus TCP
1614
modbus: tcpip
@@ -19,7 +17,7 @@ render:
1917
port: 502 # Port
2018
advanced: |
2119
type: template
22-
template: keba-modbus
20+
template: keba-modbus-p40
2321
2422
# Modbus TCP
2523
modbus: tcpip

templates/nightly/en/charger/keba-kecontact-p40.yaml

Lines changed: 4 additions & 6 deletions
Original file line numberDiff line numberDiff line change
@@ -1,16 +1,14 @@
1-
template: keba-modbus
1+
template: keba-modbus-p40
22
product:
33
identifier: keba-kecontact-p40
44
brand: KEBA
55
description: KeContact P40
6-
capabilities: ["1p3p", "mA", "rfid"]
6+
capabilities: ["mA", "rfid"]
77
requirements: ["sponsorship"]
8-
description: |
9-
Requires firmware version 3.10.42 (C-series) bzw. 1.11 (X-series). For phase switching the Keba phase switch (KeContact S10) is also required and the switching control via Modbus must be set in the wallbox settings. For the X-series in the web menu, for the C-series via Modbus by setting the value "3" in register 5050.
108
render:
119
- default: |
1210
type: template
13-
template: keba-modbus
11+
template: keba-modbus-p40
1412
1513
# Modbus TCP
1614
modbus: tcpip
@@ -19,7 +17,7 @@ render:
1917
port: 502 # Port
2018
advanced: |
2119
type: template
22-
template: keba-modbus
20+
template: keba-modbus-p40
2321
2422
# Modbus TCP
2523
modbus: tcpip

0 commit comments

Comments
 (0)