Skip to content

Commit 74fb51a

Browse files
committed
Templates update for release evcc-io/evcc@f943c9c
1 parent 5da6a74 commit 74fb51a

File tree

124 files changed

+1012
-444
lines changed

Some content is hidden

Large Commits have some content hidden by default. Use the searchbox below for content that may be hidden.

124 files changed

+1012
-444
lines changed

templates/release/de/charger/daheimladen-pro.yaml renamed to templates/release/de/charger/daheimladen-smart-touch-pro.yaml

Lines changed: 2 additions & 2 deletions
Original file line numberDiff line numberDiff line change
@@ -1,8 +1,8 @@
11
template: daheimladen-pro
22
product:
3-
identifier: daheimladen-pro
3+
identifier: daheimladen-smart-touch-pro
44
brand: DaheimLaden
5-
description: Pro
5+
description: Smart/Touch Pro
66
capabilities: ["1p3p", "mA"]
77
render:
88
- default: |

templates/release/de/charger/demo-charger.yaml

Lines changed: 5 additions & 5 deletions
Original file line numberDiff line numberDiff line change
@@ -10,15 +10,15 @@ render:
1010
type: template
1111
template: demo-charger
1212
status: A # Ladezustand, [A, B, C]
13-
power: 0 # Leistung, optional
13+
power: 0 # Leistung (W), optional
1414
enabled: true # Ladebereit, optional
1515
advanced: |
1616
type: template
1717
template: demo-charger
1818
status: A # Ladezustand, [A, B, C]
19-
power: 0 # Leistung, optional
19+
power: 0 # Leistung (W), optional
2020
enabled: true # Ladebereit, optional
21-
maxcurrent: 16 # Maximale Stromstärke (A), Definiert die maximale Stromstärke pro angeschlossener Phase mit welcher das Fahrzeug geladen werden soll (optional)
21+
maxcurrent: 16 # Maximale Stromstärke (A), Definiert die maximale Stromstärke pro angeschlossener Phase die genutzt werden kann (optional)
2222
phases1p3p: false # Phasenumschaltung, optional
2323
params:
2424
- name: status
@@ -34,7 +34,7 @@ params:
3434
example:
3535
default: 0
3636
choice: []
37-
unit:
37+
unit: W
3838
description: Leistung
3939
help:
4040
advanced: false
@@ -54,7 +54,7 @@ params:
5454
choice: []
5555
unit: A
5656
description: Maximale Stromstärke
57-
help: Definiert die maximale Stromstärke pro angeschlossener Phase mit welcher das Fahrzeug geladen werden soll
57+
help: Definiert die maximale Stromstärke pro angeschlossener Phase die genutzt werden kann
5858
advanced: true
5959
optional: true
6060
- name: phases1p3p
Lines changed: 78 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -0,0 +1,78 @@
1+
template: demo-heatpump
2+
product:
3+
identifier: demo-heat-pump
4+
description: Demowärmepumpe
5+
group: Generische Unterstützung
6+
description: |
7+
Zu Demonstrationszwecken. Wärmepumpe mit festen Werten.
8+
render:
9+
- default: |
10+
type: template
11+
template: demo-heatpump
12+
operationMode: heating # Betriebszustand, [standby, heating]
13+
power: 0 # Leistung (W), optional
14+
enabled: true # Bereit zum Heizen, optional
15+
advanced: |
16+
type: template
17+
template: demo-heatpump
18+
operationMode: heating # Betriebszustand, [standby, heating]
19+
power: 0 # Leistung (W), optional
20+
enabled: true # Bereit zum Heizen, optional
21+
soc: 50 # Temperatur (°C), optional
22+
limitSoc: 80 # Temperaturgrenze (°C), optional
23+
maxcurrent: 16 # Maximale Stromstärke (A), Definiert die maximale Stromstärke pro angeschlossener Phase die genutzt werden kann (optional)
24+
params:
25+
- name: operationMode
26+
example:
27+
default: heating
28+
choice: ['standby', 'heating']
29+
unit:
30+
description: Betriebszustand
31+
help:
32+
advanced: false
33+
optional: false
34+
- name: power
35+
example:
36+
default: 0
37+
choice: []
38+
unit: W
39+
description: Leistung
40+
help:
41+
advanced: false
42+
optional: true
43+
- name: enabled
44+
example:
45+
default: true
46+
choice: []
47+
unit:
48+
description: Bereit zum Heizen
49+
help:
50+
advanced: false
51+
optional: true
52+
- name: soc
53+
example:
54+
default: 50
55+
choice: []
56+
unit: °C
57+
description: Temperatur
58+
help:
59+
advanced: true
60+
optional: true
61+
- name: limitSoc
62+
example:
63+
default: 80
64+
choice: []
65+
unit: °C
66+
description: Temperaturgrenze
67+
help:
68+
advanced: true
69+
optional: true
70+
- name: maxcurrent
71+
example: 16
72+
default:
73+
choice: []
74+
unit: A
75+
description: Maximale Stromstärke
76+
help: Definiert die maximale Stromstärke pro angeschlossener Phase die genutzt werden kann
77+
advanced: true
78+
optional: true

templates/release/de/charger/keba-kecontact-p40-pro.yaml

Lines changed: 4 additions & 6 deletions
Original file line numberDiff line numberDiff line change
@@ -1,16 +1,14 @@
1-
template: keba-modbus
1+
template: keba-modbus-p40
22
product:
33
identifier: keba-kecontact-p40-pro
44
brand: KEBA
55
description: KeContact P40 Pro
6-
capabilities: ["1p3p", "mA", "rfid"]
6+
capabilities: ["mA", "rfid"]
77
requirements: ["sponsorship"]
8-
description: |
9-
Erfordert Firmwareversion 3.10.42 (C-series) bzw. 1.11 (X-series). Zur Phasenumschaltung wird zusätzlich der Keba Phasenumschalter (KeContact S10) benötigt und in den Wallboxeinstellungen muss die Umschaltsteuerung per Modbus aktiviert werden. Bei der x-Serie im WebMenü, bei der C-Serie per Modbus durch setzen des Wertes "3" im Register 5050.
108
render:
119
- default: |
1210
type: template
13-
template: keba-modbus
11+
template: keba-modbus-p40
1412
1513
# Modbus TCP
1614
modbus: tcpip
@@ -19,7 +17,7 @@ render:
1917
port: 502 # Port
2018
advanced: |
2119
type: template
22-
template: keba-modbus
20+
template: keba-modbus-p40
2321
2422
# Modbus TCP
2523
modbus: tcpip

templates/release/de/charger/keba-kecontact-p40.yaml

Lines changed: 4 additions & 6 deletions
Original file line numberDiff line numberDiff line change
@@ -1,16 +1,14 @@
1-
template: keba-modbus
1+
template: keba-modbus-p40
22
product:
33
identifier: keba-kecontact-p40
44
brand: KEBA
55
description: KeContact P40
6-
capabilities: ["1p3p", "mA", "rfid"]
6+
capabilities: ["mA", "rfid"]
77
requirements: ["sponsorship"]
8-
description: |
9-
Erfordert Firmwareversion 3.10.42 (C-series) bzw. 1.11 (X-series). Zur Phasenumschaltung wird zusätzlich der Keba Phasenumschalter (KeContact S10) benötigt und in den Wallboxeinstellungen muss die Umschaltsteuerung per Modbus aktiviert werden. Bei der x-Serie im WebMenü, bei der C-Serie per Modbus durch setzen des Wertes "3" im Register 5050.
108
render:
119
- default: |
1210
type: template
13-
template: keba-modbus
11+
template: keba-modbus-p40
1412
1513
# Modbus TCP
1614
modbus: tcpip
@@ -19,7 +17,7 @@ render:
1917
port: 502 # Port
2018
advanced: |
2119
type: template
22-
template: keba-modbus
20+
template: keba-modbus-p40
2321
2422
# Modbus TCP
2523
modbus: tcpip

templates/release/de/charger/lambda-eu-l-series.yaml

Lines changed: 12 additions & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -8,19 +8,21 @@ description: |
88
Energiemanagementeinstellungen am Gerät:
99
1010
- E-Meter Kommunikationsart: "ModBus Client"
11-
- E-Meter Messpunkt: "Pos. E-Überschuss"
11+
- E-Meter Messpunkt: "Pos. E-Überschuss" oder "Neg. E-Überschuss"
1212
1313
render:
1414
- default: |
1515
type: template
1616
template: lambda-zewotherm
1717
host: 192.0.2.2 # IP-Adresse oder Hostname
1818
tempsource: # Temperaturquelle, [warmwater_top, warmwater_bottom, buffer_top, buffer_bottom] (optional)
19+
excess: plus # E-Überschuss ("plus" oder "minus"), [plus, minus] (optional)
1920
advanced: |
2021
type: template
2122
template: lambda-zewotherm
2223
host: 192.0.2.2 # IP-Adresse oder Hostname
2324
tempsource: # Temperaturquelle, [warmwater_top, warmwater_bottom, buffer_top, buffer_bottom] (optional)
25+
excess: plus # E-Überschuss ("plus" oder "minus"), [plus, minus] (optional)
2426
watchdog: 60s # Watchdog, optional
2527
params:
2628
- name: host
@@ -41,6 +43,15 @@ params:
4143
help:
4244
advanced: false
4345
optional: true
46+
- name: excess
47+
example:
48+
default: plus
49+
choice: ['plus', 'minus']
50+
unit:
51+
description: E-Überschuss ("plus" oder "minus")
52+
help:
53+
advanced: false
54+
optional: true
4455
- name: watchdog
4556
example:
4657
default: 60s

templates/release/de/charger/ocpp-1-6j-compatible-smart-charging.yaml renamed to templates/release/de/charger/ocpp-1-6j-compatible.yaml

Lines changed: 2 additions & 2 deletions
Original file line numberDiff line numberDiff line change
@@ -1,7 +1,7 @@
11
template: ocpp
22
product:
3-
identifier: ocpp-1-6j-compatible-smart-charging
4-
description: OCPP 1.6J kompatibel (Smart Charging)
3+
identifier: ocpp-1-6j-compatible
4+
description: OCPP 1.6J kompatibel
55
group: Generische Unterstützung
66
capabilities: ["mA", "rfid", "1p3p"]
77
requirements: ["sponsorship", "skiptest"]

templates/release/de/charger/plugchoice.yaml

Lines changed: 2 additions & 3 deletions
Original file line numberDiff line numberDiff line change
@@ -2,17 +2,16 @@ template: plugchoice
22
product:
33
identifier: plugchoice
44
brand: Plugchoice
5-
group: Generische Unterstützung
65
requirements: ["sponsorship", "skiptest"]
76
description: |
8-
Über Plugchoice angeschlossene Ladegeräte können die OCPP-Proxy-Funktionalität nutzen, um eine Verbindung zu anderen Backoffices herzustellen und gleichzeitig die volle Kontrolle über EVCC zu behalten. Dies ermöglicht eine nahtlose Verwaltung der bei Plugchoice registrierten Ladegeräte direkt vom EVCC aus.
7+
Über Plugchoice angeschlossene Ladegeräte können die OCPP-Proxy-Funktionalität nutzen, um eine Verbindung zu anderen Backoffices herzustellen und gleichzeitig die volle Kontrolle über evcc zu behalten. Dies ermöglicht eine nahtlose Verwaltung der bei Plugchoice registrierten Ladegeräte direkt vom evcc aus.
98
109
Für eine optimierte Zählerablesung empfehlen wir, die folgenden Einstellungen im Plugchoice-Portal unter `Konfiguration` zu konfigurieren:
1110
1211
– Stellen Sie `MeterValueSampleInterval` auf 10 Sekunden (oder ein anderes Intervall Ihrer Wahl) ein.
1312
– Stellen Sie `MeterValuesSampledData` auf `Energy.Active.Import.Register,Current.Offered,Current.Import,Voltage` ein.
1413
15-
Diese Anpassungen ermöglichen eine häufigere und detailliertere Meldung der Ladedaten an EVCC.
14+
Diese Anpassungen ermöglichen eine häufigere und detailliertere Meldung der Ladedaten an evcc.
1615
1716
render:
1817
- default: |

templates/release/de/charger/zewotherm-eu-l-series.yaml

Lines changed: 12 additions & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -8,19 +8,21 @@ description: |
88
Energiemanagementeinstellungen am Gerät:
99
1010
- E-Meter Kommunikationsart: "ModBus Client"
11-
- E-Meter Messpunkt: "Pos. E-Überschuss"
11+
- E-Meter Messpunkt: "Pos. E-Überschuss" oder "Neg. E-Überschuss"
1212
1313
render:
1414
- default: |
1515
type: template
1616
template: lambda-zewotherm
1717
host: 192.0.2.2 # IP-Adresse oder Hostname
1818
tempsource: # Temperaturquelle, [warmwater_top, warmwater_bottom, buffer_top, buffer_bottom] (optional)
19+
excess: plus # E-Überschuss ("plus" oder "minus"), [plus, minus] (optional)
1920
advanced: |
2021
type: template
2122
template: lambda-zewotherm
2223
host: 192.0.2.2 # IP-Adresse oder Hostname
2324
tempsource: # Temperaturquelle, [warmwater_top, warmwater_bottom, buffer_top, buffer_bottom] (optional)
25+
excess: plus # E-Überschuss ("plus" oder "minus"), [plus, minus] (optional)
2426
watchdog: 60s # Watchdog, optional
2527
params:
2628
- name: host
@@ -41,6 +43,15 @@ params:
4143
help:
4244
advanced: false
4345
optional: true
46+
- name: excess
47+
example:
48+
default: plus
49+
choice: ['plus', 'minus']
50+
unit:
51+
description: E-Überschuss ("plus" oder "minus")
52+
help:
53+
advanced: false
54+
optional: true
4455
- name: watchdog
4556
example:
4657
default: 60s

templates/release/de/meter/senec-home.yaml

Lines changed: 2 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -4,6 +4,8 @@ product:
44
brand: SENEC
55
description: .Home
66
capabilities: ["battery-control"]
7+
description: |
8+
Batteriesteuerung umfasst nur das Netzladen, nicht die Entlade-Sperre.
79
render:
810
- usage: grid
911
default: |

0 commit comments

Comments
 (0)