templates/nightly/de/charger/lambda-eu-l-series.yaml

Lines changed: 12 additions & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -8,19 +8,21 @@ description: |
88
Energiemanagementeinstellungen am Gerät:
99
1010
- E-Meter Kommunikationsart: "ModBus Client"
11-
- E-Meter Messpunkt: "Pos. E-Überschuss"
11+
- E-Meter Messpunkt: "Pos. E-Überschuss" oder "Neg. E-Überschuss"
1212
1313
render:
1414
- default: |
1515
type: template
1616
template: lambda-zewotherm
1717
host: 192.0.2.2 # IP-Adresse oder Hostname
1818
tempsource: # Temperaturquelle, [warmwater_top, warmwater_bottom, buffer_top, buffer_bottom] (optional)
19+
excess: plus # E-Überschuss ("plus" oder "minus"), [plus, minus] (optional)
1920
advanced: |
2021
type: template
2122
template: lambda-zewotherm
2223
host: 192.0.2.2 # IP-Adresse oder Hostname
2324
tempsource: # Temperaturquelle, [warmwater_top, warmwater_bottom, buffer_top, buffer_bottom] (optional)
25+
excess: plus # E-Überschuss ("plus" oder "minus"), [plus, minus] (optional)
2426
watchdog: 60s # Watchdog, optional
2527
params:
2628
- name: host
@@ -41,6 +43,15 @@ params:
4143
help:
4244
advanced: false
4345
optional: true
46+
- name: excess
47+
example:
48+
default: plus
49+
choice: ['plus', 'minus']
50+
unit:
51+
description: E-Überschuss ("plus" oder "minus")
52+
help:
53+
advanced: false
54+
optional: true
4455
- name: watchdog
4556
example:
4657
default: 60s

templates/nightly/de/charger/zewotherm-eu-l-series.yaml

Lines changed: 12 additions & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -8,19 +8,21 @@ description: |
88
Energiemanagementeinstellungen am Gerät:
99
1010
- E-Meter Kommunikationsart: "ModBus Client"
11-
- E-Meter Messpunkt: "Pos. E-Überschuss"
11+
- E-Meter Messpunkt: "Pos. E-Überschuss" oder "Neg. E-Überschuss"
1212
1313
render:
1414
- default: |
1515
type: template
1616
template: lambda-zewotherm
1717
host: 192.0.2.2 # IP-Adresse oder Hostname
1818
tempsource: # Temperaturquelle, [warmwater_top, warmwater_bottom, buffer_top, buffer_bottom] (optional)
19+
excess: plus # E-Überschuss ("plus" oder "minus"), [plus, minus] (optional)
1920
advanced: |
2021
type: template
2122
template: lambda-zewotherm
2223
host: 192.0.2.2 # IP-Adresse oder Hostname
2324
tempsource: # Temperaturquelle, [warmwater_top, warmwater_bottom, buffer_top, buffer_bottom] (optional)
25+
excess: plus # E-Überschuss ("plus" oder "minus"), [plus, minus] (optional)
2426
watchdog: 60s # Watchdog, optional
2527
params:
2628
- name: host
@@ -41,6 +43,15 @@ params:
4143
help:
4244
advanced: false
4345
optional: true
46+
- name: excess
47+
example:
48+
default: plus
49+
choice: ['plus', 'minus']
50+
unit:
51+
description: E-Überschuss ("plus" oder "minus")
52+
help:
53+
advanced: false
54+
optional: true
4455
- name: watchdog
4556
example:
4657
default: 60s

templates/nightly/en/charger/lambda-eu-l-series.yaml

Lines changed: 12 additions & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -8,19 +8,21 @@ description: |
88
Energy management settings of the device:
99
1010
- E-Meter communication type: "ModBus Client"
11-
- E-Meter measuring point: "Pos. E-Überschuss"
11+
- E-Meter measuring point: "Pos. Excess Energy" or "Neg. Excess Energy"
1212
1313
render:
1414
- default: |
1515
type: template
1616
template: lambda-zewotherm
1717
host: 192.0.2.2 # IP address or hostname
1818
tempsource: # Temperature source, [warmwater_top, warmwater_bottom, buffer_top, buffer_bottom] (optional)
19+
excess: plus # Excess Energy ("plus" or "minus"), [plus, minus] (optional)
1920
advanced: |
2021
type: template
2122
template: lambda-zewotherm
2223
host: 192.0.2.2 # IP address or hostname
2324
tempsource: # Temperature source, [warmwater_top, warmwater_bottom, buffer_top, buffer_bottom] (optional)
25+
excess: plus # Excess Energy ("plus" or "minus"), [plus, minus] (optional)
2426
watchdog: 60s # Watchdog, optional
2527
params:
2628
- name: host
@@ -41,6 +43,15 @@ params:
4143
help:
4244
advanced: false
4345
optional: true
46+
- name: excess
47+
example:
48+
default: plus
49+
choice: ['plus', 'minus']
50+
unit:
51+
description: Excess Energy ("plus" or "minus")
52+
help:
53+
advanced: false
54+
optional: true
4455
- name: watchdog
4556
example:
4657
default: 60s

templates/nightly/en/charger/zewotherm-eu-l-series.yaml

Lines changed: 12 additions & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -8,19 +8,21 @@ description: |
88
Energy management settings of the device:
99
1010
- E-Meter communication type: "ModBus Client"
11-
- E-Meter measuring point: "Pos. E-Überschuss"
11+
- E-Meter measuring point: "Pos. Excess Energy" or "Neg. Excess Energy"
1212
1313
render:
1414
- default: |
1515
type: template
1616
template: lambda-zewotherm
1717
host: 192.0.2.2 # IP address or hostname
1818
tempsource: # Temperature source, [warmwater_top, warmwater_bottom, buffer_top, buffer_bottom] (optional)
19+
excess: plus # Excess Energy ("plus" or "minus"), [plus, minus] (optional)
1920
advanced: |
2021
type: template
2122
template: lambda-zewotherm
2223
host: 192.0.2.2 # IP address or hostname
2324
tempsource: # Temperature source, [warmwater_top, warmwater_bottom, buffer_top, buffer_bottom] (optional)
25+
excess: plus # Excess Energy ("plus" or "minus"), [plus, minus] (optional)
2426
watchdog: 60s # Watchdog, optional
2527
params:
2628
- name: host
@@ -41,6 +43,15 @@ params:
4143
help:
4244
advanced: false
4345
optional: true
46+
- name: excess
47+
example:
48+
default: plus
49+
choice: ['plus', 'minus']
50+
unit:
51+
description: Excess Energy ("plus" or "minus")
52+
help: