docs/faq.mdx

Lines changed: 3 additions & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -235,7 +235,9 @@ Um dennoch möglichst viel eigenen Strom ins Fahrzeug zu laden, kann man folgend
235235

236236
#### mittels `residualpower`
237237

238-
In der Konfiguration unter [`site`](/docs/reference/configuration/site) setzt man [`residualPower`](/docs/reference/configuration/site#residualpower) auf einen negativen Wert. Dieser bestimmt dann wieviel Netzbezug im PV Modus noch erlaubt ist. Eine Änderung ist per API möglich.
238+
In der Konfiguration unter [`site`](/docs/reference/configuration/site) setzt man [`residualPower`](/docs/reference/configuration/site#residualpower) auf einen negativen Wert.
239+
Dieser bestimmt dann wieviel Netzbezug im PV Modus noch erlaubt ist.
240+
Eine Änderung ist per API möglich.
239241

240242
**Beispiel**:
241243

docs/reference/configuration/site.mdx

Lines changed: 6 additions & 3 deletions
Original file line numberDiff line numberDiff line change
@@ -164,7 +164,8 @@ aux:
164164

165165
### `residualPower`
166166

167-
Legt den Soll-Arbeitspunkt der Überschussregelung am Netzübergang (Gridmeter) fest. Der Standardwert ist 0 (Watt).
167+
Legt den Soll-Arbeitspunkt der Überschussregelung am Netzübergang (`grid`) fest.
168+
Der Standardwert ist 100 W.
168169
Positive Werte verschieben den Sollwert in Richtung Netzeinspeisung, negative Werte in Richtung Netzbezug.
169170
Mit diesem Wert wird der durch die Steuerung einzustellende "Ruhezustand" des Regelkreises eingestellt.
170171

@@ -183,8 +184,10 @@ Soll im PV-Modus ein Netzbezugsanteil verbleiben bzw. zugelassen werden, muss hi
183184
- Negativer Wert: angegebene Leistung wird zur PV-Leistung addiert und erhöht die zur Verfügung stehende Ladeleistung (Achtung: Netzbezug)
184185

185186
:::info
186-
Bei Existenz eines Batteriespeichers wird dringend empfohlen hier einen kleinen Wert von 100 bis 300 (Watt) einzutragen, um damit eine Speicherladung gemäß der konfigurierten Prioritäten (siehe `prioritySoc`) zu ermöglichen. Andernfalls "sieht" die unabhängige Regelung des Speichers keinen nutzbaren Überschuss.
187-
Ebenso lässt sich damit bei schnellen Erzeugungs- und Lastwechseln auch ohne Speicher ein kurzzeitiger Netzbezug besser vermeiden.
187+
Der Standardwert von 100 W gibt Hausbatterien eine leichte Priorität gegenüber dem Netzbezug.
188+
Dies ermöglicht eine Speicherladung gemäß der konfigurierten Prioritäten (siehe `prioritySoc`).
189+
Wenn du keine Batterie hast, kannst du den Wert auf 0 W setzen, um den Netzbezug im PV-Modus zu minimieren.
190+
Bei schnellen Erzeugungs- und Lastwechseln kann ein positiver Wert auch ohne Speicher einen kurzzeitigen Netzbezug besser vermeiden.
188191
:::
189192

190193
**Beispiel "Batteriespeicher"**:

i18n/en/docusaurus-plugin-content-docs/current/faq.mdx

Lines changed: 4 additions & 2 deletions
Original file line numberDiff line numberDiff line change
@@ -241,9 +241,11 @@ In order to get as much energy into the Vehicle as possible, you can try some of
241241

242242
#### Using `residualpower`
243243

244-
In the configuration under the [`site`](/docs/reference/configuration/site) flag, set [`residualPower`](/docs/reference/configuration/site#residualpower) to a **negative** value. This determines how much power the grid can supply to nudge your solar production up enough to cover the minimum. Changes are possible via the API.
244+
In the configuration under the [`site`](/docs/reference/configuration/site) flag, set [`residualPower`](/docs/reference/configuration/site#residualpower) to a **negative** value.
245+
This determines how much power the grid can supply to nudge your solar production up enough to cover the minimum.
246+
Changes are possible via the API.
245247

246-
**Exmaple**:
248+
**Example**:
247249

248250
```yaml
249251
site:

i18n/en/docusaurus-plugin-content-docs/current/reference/configuration/site.mdx

Lines changed: 6 additions & 2 deletions
Original file line numberDiff line numberDiff line change
@@ -163,7 +163,8 @@ aux:
163163

164164
### `residualPower`
165165

166-
Sets the target operating point of the surplus regulation at the grid connection (grid meter). The default value is 0 W.
166+
Sets the target operating point of the surplus regulation at the grid connection (grid meter).
167+
The default value is 100 W.
167168
Positive values shift the target value towards grid feed-in, while negative values shift it towards grid consumption.
168169
Ultimately, this value sets the "idle state" of the control loop that needs to be adjusted by the controller.
169170

@@ -182,7 +183,10 @@ If a certain proportion of grid consumption should remain or be allowed in PV mo
182183
- Negative value: The specified power is added to PV power and increases available charging power (Attention: grid consumption)
183184

184185
:::info
185-
When a battery storage is present, it is strongly recommended to enter a small value, e.g. between 100 to 300 W here, allowing battery charging according to configured priorities (see `prioritySoc`). Otherwise, the independent regulation of the storage will not see usable surplus. Likewise, this prevents temporary grid consumption even without a battery during rapid generation and load changes.
186+
The default of 100 W gives home batteries slight priority over grid use.
187+
This allows battery charging according to configured priorities (see `prioritySoc`).
188+
If you don't have a battery, you can set this to 0 W to minimise grid consumption in solar mode.
189+
A positive value can also prevent temporary grid consumption even without a battery during rapid generation and load changes.
186190
:::
187191

188192
**Example "Battery Storage"**:

0 commit comments

Comments