@@ -7556,7 +7556,31 @@ Die Verbindung über einen LSE-3 Logger Stick mittels LAN Anschluss und ModBus T
7556
7556
modbus: tcpip
7557
7557
id: 1
7558
7558
host: 192.0.2.2 # Hostname
7559
-
port: 8899 # Port`} />
7559
+
port: 8899 # Port`} advanced={`meters:
7560
+
- name: my_grid
7561
+
type: template
7562
+
template: sofarsolar-g3
7563
+
usage: grid
7564
+
7565
+
# RS485 via adapter (Modbus RTU)
7566
+
modbus: rs485serial
7567
+
id: 1
7568
+
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
7569
+
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
7570
+
comset: "8N1" # Kommunikationsparameter für den Adapter
7571
+
7572
+
# RS485 via TCP/IP (Modbus RTU)
7573
+
modbus: rs485tcpip
7574
+
id: 1
7575
+
host: 192.0.2.2 # Hostname
7576
+
port: 8899 # Port
7577
+
7578
+
# Modbus TCP
7579
+
modbus: tcpip
7580
+
id: 1
7581
+
host: 192.0.2.2 # Hostname
7582
+
port: 8899 # Port
7583
+
storageunit: 1 # Nummer des Batteriespeichers. Im Fall eines BTS Speichers nicht die Adresse eines BTS 5K Batteriemodules, sondern der Speicherturm (BTS 5K-BDU Steuerungseinheit mit 1-4 BTS 5K Modulen). (optional)`} />
7560
7584
7561
7585
7562
7586
@@ -7610,6 +7634,7 @@ Die Verbindung über einen LSE-3 Logger Stick mittels LAN Anschluss und ModBus T
7610
7634
id: 1
7611
7635
host: 192.0.2.2 # Hostname
7612
7636
port: 8899 # Port
7637
+
storageunit: 1 # Nummer des Batteriespeichers. Im Fall eines BTS Speichers nicht die Adresse eines BTS 5K Batteriemodules, sondern der Speicherturm (BTS 5K-BDU Steuerungseinheit mit 1-4 BTS 5K Modulen). (optional)
7613
7638
maxacpower: 0 # Maximale AC Leistung des Hybrid-Wechselrichters (optional)`} />
7614
7639
7615
7640
@@ -7664,6 +7689,7 @@ Die Verbindung über einen LSE-3 Logger Stick mittels LAN Anschluss und ModBus T
7664
7689
id: 1
7665
7690
host: 192.0.2.2 # Hostname
7666
7691
port: 8899 # Port
7692
+
storageunit: 1 # Nummer des Batteriespeichers. Im Fall eines BTS Speichers nicht die Adresse eines BTS 5K Batteriemodules, sondern der Speicherturm (BTS 5K-BDU Steuerungseinheit mit 1-4 BTS 5K Modulen). (optional)
7667
7693
capacity: 50 # Akkukapazität in kWh (optional)
7668
7694
defaultmode: 0 # Standardmodus für die aktive Batteriesteuerung. Gültige Werte sind 0 (Eigenbedarfsmodus), 1 (Nutzungszeitmodus), 2 (Zeitmodus), 4 (Peak-shaving Modus) (optional)`} />
7669
7695
@@ -7706,7 +7732,31 @@ Die Verbindung über einen LSE-3 Logger Stick mittels LAN Anschluss und ModBus T
7706
7732
modbus: tcpip
7707
7733
id: 1
7708
7734
host: 192.0.2.2 # Hostname
7709
-
port: 8899 # Port`} />
7735
+
port: 8899 # Port`} advanced={`meters:
7736
+
- name: my_grid
7737
+
type: template
7738
+
template: sofarsolar-g3
7739
+
usage: grid
7740
+
7741
+
# RS485 via adapter (Modbus RTU)
7742
+
modbus: rs485serial
7743
+
id: 1
7744
+
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
7745
+
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
7746
+
comset: "8N1" # Kommunikationsparameter für den Adapter
7747
+
7748
+
# RS485 via TCP/IP (Modbus RTU)
7749
+
modbus: rs485tcpip
7750
+
id: 1
7751
+
host: 192.0.2.2 # Hostname
7752
+
port: 8899 # Port
7753
+
7754
+
# Modbus TCP
7755
+
modbus: tcpip
7756
+
id: 1
7757
+
host: 192.0.2.2 # Hostname
7758
+
port: 8899 # Port
7759
+
storageunit: 1 # Nummer des Batteriespeichers. Im Fall eines BTS Speichers nicht die Adresse eines BTS 5K Batteriemodules, sondern der Speicherturm (BTS 5K-BDU Steuerungseinheit mit 1-4 BTS 5K Modulen). (optional)`} />
7710
7760
7711
7761
7712
7762
@@ -7760,6 +7810,7 @@ Die Verbindung über einen LSE-3 Logger Stick mittels LAN Anschluss und ModBus T
7760
7810
id: 1
7761
7811
host: 192.0.2.2 # Hostname
7762
7812
port: 8899 # Port
7813
+
storageunit: 1 # Nummer des Batteriespeichers. Im Fall eines BTS Speichers nicht die Adresse eines BTS 5K Batteriemodules, sondern der Speicherturm (BTS 5K-BDU Steuerungseinheit mit 1-4 BTS 5K Modulen). (optional)
7763
7814
maxacpower: 0 # Maximale AC Leistung des Hybrid-Wechselrichters (optional)`} />
7764
7815
7765
7816
@@ -7814,6 +7865,7 @@ Die Verbindung über einen LSE-3 Logger Stick mittels LAN Anschluss und ModBus T
7814
7865
id: 1
7815
7866
host: 192.0.2.2 # Hostname
7816
7867
port: 8899 # Port
7868
+
storageunit: 1 # Nummer des Batteriespeichers. Im Fall eines BTS Speichers nicht die Adresse eines BTS 5K Batteriemodules, sondern der Speicherturm (BTS 5K-BDU Steuerungseinheit mit 1-4 BTS 5K Modulen). (optional)
7817
7869
capacity: 50 # Akkukapazität in kWh (optional)
7818
7870
defaultmode: 0 # Standardmodus für die aktive Batteriesteuerung. Gültige Werte sind 0 (Eigenbedarfsmodus), 1 (Nutzungszeitmodus), 2 (Zeitmodus), 4 (Peak-shaving Modus) (optional)`} />
7819
7871
@@ -7979,7 +8031,31 @@ Die Verbindung über einen LSE-3 Logger Stick mittels LAN Anschluss und ModBus T
7979
8031
modbus: tcpip
7980
8032
id: 1
7981
8033
host: 192.0.2.2 # Hostname
7982
-
port: 8899 # Port`} />
8034
+
port: 8899 # Port`} advanced={`meters:
8035
+
- name: my_grid
8036
+
type: template
8037
+
template: sofarsolar-g3
8038
+
usage: grid
8039
+
8040
+
# RS485 via adapter (Modbus RTU)
8041
+
modbus: rs485serial
8042
+
id: 1
8043
+
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
8044
+
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
8045
+
comset: "8N1" # Kommunikationsparameter für den Adapter
8046
+
8047
+
# RS485 via TCP/IP (Modbus RTU)
8048
+
modbus: rs485tcpip
8049
+
id: 1
8050
+
host: 192.0.2.2 # Hostname
8051
+
port: 8899 # Port
8052
+
8053
+
# Modbus TCP
8054
+
modbus: tcpip
8055
+
id: 1
8056
+
host: 192.0.2.2 # Hostname
8057
+
port: 8899 # Port
8058
+
storageunit: 1 # Nummer des Batteriespeichers. Im Fall eines BTS Speichers nicht die Adresse eines BTS 5K Batteriemodules, sondern der Speicherturm (BTS 5K-BDU Steuerungseinheit mit 1-4 BTS 5K Modulen). (optional)`} />
7983
8059
7984
8060
7985
8061
@@ -8033,6 +8109,7 @@ Die Verbindung über einen LSE-3 Logger Stick mittels LAN Anschluss und ModBus T
8033
8109
id: 1
8034
8110
host: 192.0.2.2 # Hostname
8035
8111
port: 8899 # Port
8112
+
storageunit: 1 # Nummer des Batteriespeichers. Im Fall eines BTS Speichers nicht die Adresse eines BTS 5K Batteriemodules, sondern der Speicherturm (BTS 5K-BDU Steuerungseinheit mit 1-4 BTS 5K Modulen). (optional)
8036
8113
maxacpower: 0 # Maximale AC Leistung des Hybrid-Wechselrichters (optional)`} />
8037
8114
8038
8115
@@ -8087,6 +8164,7 @@ Die Verbindung über einen LSE-3 Logger Stick mittels LAN Anschluss und ModBus T
8087
8164
id: 1
8088
8165
host: 192.0.2.2 # Hostname
8089
8166
port: 8899 # Port
8167
+
storageunit: 1 # Nummer des Batteriespeichers. Im Fall eines BTS Speichers nicht die Adresse eines BTS 5K Batteriemodules, sondern der Speicherturm (BTS 5K-BDU Steuerungseinheit mit 1-4 BTS 5K Modulen). (optional)
8090
8168
capacity: 50 # Akkukapazität in kWh (optional)
8091
8169
defaultmode: 0 # Standardmodus für die aktive Batteriesteuerung. Gültige Werte sind 0 (Eigenbedarfsmodus), 1 (Nutzungszeitmodus), 2 (Zeitmodus), 4 (Peak-shaving Modus) (optional)`} />
8092
8170
@@ -8129,7 +8207,31 @@ Die Verbindung über einen LSE-3 Logger Stick mittels LAN Anschluss und ModBus T
8129
8207
modbus: tcpip
8130
8208
id: 1
8131
8209
host: 192.0.2.2 # Hostname
8132
-
port: 8899 # Port`} />
8210
+
port: 8899 # Port`} advanced={`meters:
8211
+
- name: my_grid
8212
+
type: template
8213
+
template: sofarsolar-g3
8214
+
usage: grid
8215
+
8216
+
# RS485 via adapter (Modbus RTU)
8217
+
modbus: rs485serial
8218
+
id: 1
8219
+
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
8220
+
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
8221
+
comset: "8N1" # Kommunikationsparameter für den Adapter
8222
+
8223
+
# RS485 via TCP/IP (Modbus RTU)
8224
+
modbus: rs485tcpip
8225
+
id: 1
8226
+
host: 192.0.2.2 # Hostname
8227
+
port: 8899 # Port
8228
+
8229
+
# Modbus TCP
8230
+
modbus: tcpip
8231
+
id: 1
8232
+
host: 192.0.2.2 # Hostname
8233
+
port: 8899 # Port
8234
+
storageunit: 1 # Nummer des Batteriespeichers. Im Fall eines BTS Speichers nicht die Adresse eines BTS 5K Batteriemodules, sondern der Speicherturm (BTS 5K-BDU Steuerungseinheit mit 1-4 BTS 5K Modulen). (optional)`} />
8133
8235
8134
8236
8135
8237
@@ -8183,6 +8285,7 @@ Die Verbindung über einen LSE-3 Logger Stick mittels LAN Anschluss und ModBus T
8183
8285
id: 1
8184
8286
host: 192.0.2.2 # Hostname
8185
8287
port: 8899 # Port
8288
+
storageunit: 1 # Nummer des Batteriespeichers. Im Fall eines BTS Speichers nicht die Adresse eines BTS 5K Batteriemodules, sondern der Speicherturm (BTS 5K-BDU Steuerungseinheit mit 1-4 BTS 5K Modulen). (optional)
8186
8289
maxacpower: 0 # Maximale AC Leistung des Hybrid-Wechselrichters (optional)`} />
8187
8290
8188
8291
@@ -8237,6 +8340,7 @@ Die Verbindung über einen LSE-3 Logger Stick mittels LAN Anschluss und ModBus T
8237
8340
id: 1
8238
8341
host: 192.0.2.2 # Hostname
8239
8342
port: 8899 # Port
8343
+
storageunit: 1 # Nummer des Batteriespeichers. Im Fall eines BTS Speichers nicht die Adresse eines BTS 5K Batteriemodules, sondern der Speicherturm (BTS 5K-BDU Steuerungseinheit mit 1-4 BTS 5K Modulen). (optional)
8240
8344
capacity: 50 # Akkukapazität in kWh (optional)
8241
8345
defaultmode: 0 # Standardmodus für die aktive Batteriesteuerung. Gültige Werte sind 0 (Eigenbedarfsmodus), 1 (Nutzungszeitmodus), 2 (Zeitmodus), 4 (Peak-shaving Modus) (optional)`} />
Copy file name to clipboardExpand all lines: i18n/en/docusaurus-plugin-content-docs/current/devices/meters.mdx
+108-4Lines changed: 108 additions & 4 deletions
Display the source diff
Display the rich diff
Original file line number
Diff line number
Diff line change
@@ -7557,7 +7557,31 @@ LSE-3 logger stick using a LAN connection and ModBus TCP via the port 8899 is th
7557
7557
modbus: tcpip
7558
7558
id: 1
7559
7559
host: 192.0.2.2 # Hostname
7560
-
port: 8899 # Port`} />
7560
+
port: 8899 # Port`} advanced={`meters:
7561
+
- name: my_grid
7562
+
type: template
7563
+
template: sofarsolar-g3
7564
+
usage: grid
7565
+
7566
+
# RS485 via adapter (Modbus RTU)
7567
+
modbus: rs485serial
7568
+
id: 1
7569
+
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
7570
+
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
7571
+
comset: "8N1" # Kommunikationsparameter für den Adapter
7572
+
7573
+
# RS485 via TCP/IP (Modbus RTU)
7574
+
modbus: rs485tcpip
7575
+
id: 1
7576
+
host: 192.0.2.2 # Hostname
7577
+
port: 8899 # Port
7578
+
7579
+
# Modbus TCP
7580
+
modbus: tcpip
7581
+
id: 1
7582
+
host: 192.0.2.2 # Hostname
7583
+
port: 8899 # Port
7584
+
storageunit: 1 # Number of the battery storage. In case of a BTS storage not the address of a BTS 5K battery module, but the storage tower (BTS 5K-BDU control unit with 1-4 BTS 5K modules). (optional)`} />
7561
7585
7562
7586
7563
7587
@@ -7611,6 +7635,7 @@ LSE-3 logger stick using a LAN connection and ModBus TCP via the port 8899 is th
7611
7635
id: 1
7612
7636
host: 192.0.2.2 # Hostname
7613
7637
port: 8899 # Port
7638
+
storageunit: 1 # Number of the battery storage. In case of a BTS storage not the address of a BTS 5K battery module, but the storage tower (BTS 5K-BDU control unit with 1-4 BTS 5K modules). (optional)
7614
7639
maxacpower: 0 # Maximum AC power of the hybrid inverter (optional)`} />
7615
7640
7616
7641
@@ -7665,6 +7690,7 @@ LSE-3 logger stick using a LAN connection and ModBus TCP via the port 8899 is th
7665
7690
id: 1
7666
7691
host: 192.0.2.2 # Hostname
7667
7692
port: 8899 # Port
7693
+
storageunit: 1 # Number of the battery storage. In case of a BTS storage not the address of a BTS 5K battery module, but the storage tower (BTS 5K-BDU control unit with 1-4 BTS 5K modules). (optional)
7668
7694
capacity: 50 # Battery capacity in kWh (optional)
7669
7695
defaultmode: 0 # Default mode for battery control. Valid values are 0 (self use), 1 (time of use), 2 (timing mode), 4 (peak-shaving mode) (optional)`} />
7670
7696
@@ -7707,7 +7733,31 @@ LSE-3 logger stick using a LAN connection and ModBus TCP via the port 8899 is th
7707
7733
modbus: tcpip
7708
7734
id: 1
7709
7735
host: 192.0.2.2 # Hostname
7710
-
port: 8899 # Port`} />
7736
+
port: 8899 # Port`} advanced={`meters:
7737
+
- name: my_grid
7738
+
type: template
7739
+
template: sofarsolar-g3
7740
+
usage: grid
7741
+
7742
+
# RS485 via adapter (Modbus RTU)
7743
+
modbus: rs485serial
7744
+
id: 1
7745
+
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
7746
+
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
7747
+
comset: "8N1" # Kommunikationsparameter für den Adapter
7748
+
7749
+
# RS485 via TCP/IP (Modbus RTU)
7750
+
modbus: rs485tcpip
7751
+
id: 1
7752
+
host: 192.0.2.2 # Hostname
7753
+
port: 8899 # Port
7754
+
7755
+
# Modbus TCP
7756
+
modbus: tcpip
7757
+
id: 1
7758
+
host: 192.0.2.2 # Hostname
7759
+
port: 8899 # Port
7760
+
storageunit: 1 # Number of the battery storage. In case of a BTS storage not the address of a BTS 5K battery module, but the storage tower (BTS 5K-BDU control unit with 1-4 BTS 5K modules). (optional)`} />
7711
7761
7712
7762
7713
7763
@@ -7761,6 +7811,7 @@ LSE-3 logger stick using a LAN connection and ModBus TCP via the port 8899 is th
7761
7811
id: 1
7762
7812
host: 192.0.2.2 # Hostname
7763
7813
port: 8899 # Port
7814
+
storageunit: 1 # Number of the battery storage. In case of a BTS storage not the address of a BTS 5K battery module, but the storage tower (BTS 5K-BDU control unit with 1-4 BTS 5K modules). (optional)
7764
7815
maxacpower: 0 # Maximum AC power of the hybrid inverter (optional)`} />
7765
7816
7766
7817
@@ -7815,6 +7866,7 @@ LSE-3 logger stick using a LAN connection and ModBus TCP via the port 8899 is th
7815
7866
id: 1
7816
7867
host: 192.0.2.2 # Hostname
7817
7868
port: 8899 # Port
7869
+
storageunit: 1 # Number of the battery storage. In case of a BTS storage not the address of a BTS 5K battery module, but the storage tower (BTS 5K-BDU control unit with 1-4 BTS 5K modules). (optional)
7818
7870
capacity: 50 # Battery capacity in kWh (optional)
7819
7871
defaultmode: 0 # Default mode for battery control. Valid values are 0 (self use), 1 (time of use), 2 (timing mode), 4 (peak-shaving mode) (optional)`} />
7820
7872
@@ -7980,7 +8032,31 @@ LSE-3 logger stick using a LAN connection and ModBus TCP via the port 8899 is th
7980
8032
modbus: tcpip
7981
8033
id: 1
7982
8034
host: 192.0.2.2 # Hostname
7983
-
port: 8899 # Port`} />
8035
+
port: 8899 # Port`} advanced={`meters:
8036
+
- name: my_grid
8037
+
type: template
8038
+
template: sofarsolar-g3
8039
+
usage: grid
8040
+
8041
+
# RS485 via adapter (Modbus RTU)
8042
+
modbus: rs485serial
8043
+
id: 1
8044
+
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
8045
+
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
8046
+
comset: "8N1" # Kommunikationsparameter für den Adapter
8047
+
8048
+
# RS485 via TCP/IP (Modbus RTU)
8049
+
modbus: rs485tcpip
8050
+
id: 1
8051
+
host: 192.0.2.2 # Hostname
8052
+
port: 8899 # Port
8053
+
8054
+
# Modbus TCP
8055
+
modbus: tcpip
8056
+
id: 1
8057
+
host: 192.0.2.2 # Hostname
8058
+
port: 8899 # Port
8059
+
storageunit: 1 # Number of the battery storage. In case of a BTS storage not the address of a BTS 5K battery module, but the storage tower (BTS 5K-BDU control unit with 1-4 BTS 5K modules). (optional)`} />
7984
8060
7985
8061
7986
8062
@@ -8034,6 +8110,7 @@ LSE-3 logger stick using a LAN connection and ModBus TCP via the port 8899 is th
8034
8110
id: 1
8035
8111
host: 192.0.2.2 # Hostname
8036
8112
port: 8899 # Port
8113
+
storageunit: 1 # Number of the battery storage. In case of a BTS storage not the address of a BTS 5K battery module, but the storage tower (BTS 5K-BDU control unit with 1-4 BTS 5K modules). (optional)
8037
8114
maxacpower: 0 # Maximum AC power of the hybrid inverter (optional)`} />
8038
8115
8039
8116
@@ -8088,6 +8165,7 @@ LSE-3 logger stick using a LAN connection and ModBus TCP via the port 8899 is th
8088
8165
id: 1
8089
8166
host: 192.0.2.2 # Hostname
8090
8167
port: 8899 # Port
8168
+
storageunit: 1 # Number of the battery storage. In case of a BTS storage not the address of a BTS 5K battery module, but the storage tower (BTS 5K-BDU control unit with 1-4 BTS 5K modules). (optional)
8091
8169
capacity: 50 # Battery capacity in kWh (optional)
8092
8170
defaultmode: 0 # Default mode for battery control. Valid values are 0 (self use), 1 (time of use), 2 (timing mode), 4 (peak-shaving mode) (optional)`} />
8093
8171
@@ -8130,7 +8208,31 @@ LSE-3 logger stick using a LAN connection and ModBus TCP via the port 8899 is th
8130
8208
modbus: tcpip
8131
8209
id: 1
8132
8210
host: 192.0.2.2 # Hostname
8133
-
port: 8899 # Port`} />
8211
+
port: 8899 # Port`} advanced={`meters:
8212
+
- name: my_grid
8213
+
type: template
8214
+
template: sofarsolar-g3
8215
+
usage: grid
8216
+
8217
+
# RS485 via adapter (Modbus RTU)
8218
+
modbus: rs485serial
8219
+
id: 1
8220
+
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
8221
+
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
8222
+
comset: "8N1" # Kommunikationsparameter für den Adapter
8223
+
8224
+
# RS485 via TCP/IP (Modbus RTU)
8225
+
modbus: rs485tcpip
8226
+
id: 1
8227
+
host: 192.0.2.2 # Hostname
8228
+
port: 8899 # Port
8229
+
8230
+
# Modbus TCP
8231
+
modbus: tcpip
8232
+
id: 1
8233
+
host: 192.0.2.2 # Hostname
8234
+
port: 8899 # Port
8235
+
storageunit: 1 # Number of the battery storage. In case of a BTS storage not the address of a BTS 5K battery module, but the storage tower (BTS 5K-BDU control unit with 1-4 BTS 5K modules). (optional)`} />
8134
8236
8135
8237
8136
8238
@@ -8184,6 +8286,7 @@ LSE-3 logger stick using a LAN connection and ModBus TCP via the port 8899 is th
8184
8286
id: 1
8185
8287
host: 192.0.2.2 # Hostname
8186
8288
port: 8899 # Port
8289
+
storageunit: 1 # Number of the battery storage. In case of a BTS storage not the address of a BTS 5K battery module, but the storage tower (BTS 5K-BDU control unit with 1-4 BTS 5K modules). (optional)
8187
8290
maxacpower: 0 # Maximum AC power of the hybrid inverter (optional)`} />
8188
8291
8189
8292
@@ -8238,6 +8341,7 @@ LSE-3 logger stick using a LAN connection and ModBus TCP via the port 8899 is th
8238
8341
id: 1
8239
8342
host: 192.0.2.2 # Hostname
8240
8343
port: 8899 # Port
8344
+
storageunit: 1 # Number of the battery storage. In case of a BTS storage not the address of a BTS 5K battery module, but the storage tower (BTS 5K-BDU control unit with 1-4 BTS 5K modules). (optional)
8241
8345
capacity: 50 # Battery capacity in kWh (optional)
8242
8346
defaultmode: 0 # Default mode for battery control. Valid values are 0 (self use), 1 (time of use), 2 (timing mode), 4 (peak-shaving mode) (optional)`} />