Skip to content

Amperfied solar.connect Phase Switching #16287

@maatinh

Description

@maatinh

Describe the bug

evcc is not phase switching correctly. I used "Fast"-Charging yday and evcc switched from 1p to 3p. Today I wanted to charge using PV-Mode but the WB is not switching phases.
Please let me know what exactly you need to and what I need to do to provide the correct logs. I could switch phases manually back to 1p.

Steps to reproduce

  1. WB is configured to use 3p
  2. start PV charging where not enough pv power is available for 3p

Configuration details

WB is configured using UI as well as the Car.

Log details

[site  ] DEBUG 2024/09/23 11:13:44 ----
[lp-1  ] DEBUG 2024/09/23 11:13:44 charge power: 0W
[lp-1  ] DEBUG 2024/09/23 11:13:44 charge currents: [0 0 0]A
[lp-2  ] DEBUG 2024/09/23 11:13:44 charge power: 0W
[lp-2  ] DEBUG 2024/09/23 11:13:44 charge currents: [0 0 0]A
[circuit-leitung_garage] DEBUG 2024/09/23 11:13:44 power: 0W
[circuit-leitung_garage] DEBUG 2024/09/23 11:13:44 current: 0A
[site  ] DEBUG 2024/09/23 11:13:45 pv power: 3296W
[site  ] DEBUG 2024/09/23 11:13:45 battery soc: 87%
[site  ] DEBUG 2024/09/23 11:13:45 battery power: -2943W
[site  ] DEBUG 2024/09/23 11:13:45 grid meter: -17W
[site  ] DEBUG 2024/09/23 11:13:46 site power: -2860W
[lp-1  ] DEBUG 2024/09/23 11:13:46 charge total import: 823.236kWh
[lp-1  ] DEBUG 2024/09/23 11:13:46 charger status: B
[lp-1  ] DEBUG 2024/09/23 11:13:46 pv charge current: 12.4A = 0A + 12.4A (-2860W @ 1p)
[lp-1  ] DEBUG 2024/09/23 11:13:46 site power -2860W <= 0W enable threshold
[lp-1  ] DEBUG 2024/09/23 11:13:46 pv enable in 0s
[lp-1  ] DEBUG 2024/09/23 11:13:46 pv enable timer elapsed
[circuit-leitung_garage] TRACE 2024/09/23 11:13:46 validate current: 0A + (0A -> 7A) <= 32A ok
[circuit-leitung_garage] TRACE 2024/09/23 11:13:46 validate power: 0W + (0W -> 1610W) <= 20000W ok
[lp-1  ] DEBUG 2024/09/23 11:13:46 max charge current: 7A
[lp-1  ] DEBUG 2024/09/23 11:13:46 charger enable
[lp-1  ] DEBUG 2024/09/23 11:13:46 wake-up timer: start
[site  ] DEBUG 2024/09/23 11:14:14 ----
[lp-1  ] DEBUG 2024/09/23 11:14:14 charge power: 4679W
[lp-1  ] DEBUG 2024/09/23 11:14:14 charge currents: [6.5 6.7 6.7]A
[lp-2  ] DEBUG 2024/09/23 11:14:14 charge power: 0W
[lp-2  ] DEBUG 2024/09/23 11:14:14 charge currents: [0 0 0]A
[circuit-leitung_garage] DEBUG 2024/09/23 11:14:14 power: 4679W
[circuit-leitung_garage] DEBUG 2024/09/23 11:14:14 current: 6.7A
[site  ] DEBUG 2024/09/23 11:14:15 pv power: 3818W
[site  ] DEBUG 2024/09/23 11:14:15 battery soc: 87%
[site  ] DEBUG 2024/09/23 11:14:15 battery power: 1156W
[site  ] DEBUG 2024/09/23 11:14:15 grid meter: 13W
[site  ] DEBUG 2024/09/23 11:14:16 site power: 1269W
[lp-2  ] DEBUG 2024/09/23 11:14:16 charge total import: 0.060kWh
[lp-2  ] DEBUG 2024/09/23 11:14:16 charger status: A
[circuit-leitung_garage] TRACE 2024/09/23 11:14:16 validate current: 6.7A + (0A -> 0A) <= 32A ok
[circuit-leitung_garage] TRACE 2024/09/23 11:14:16 validate power: 4679W + (0W -> 0W) <= 20000W ok
[site  ] DEBUG 2024/09/23 11:14:44 ----
[lp-1  ] DEBUG 2024/09/23 11:14:44 charge power: 4656W
[lp-1  ] DEBUG 2024/09/23 11:14:44 charge currents: [6.5 6.7 6.7]A
[lp-2  ] DEBUG 2024/09/23 11:14:44 charge power: 0W
[lp-2  ] DEBUG 2024/09/23 11:14:44 charge currents: [0 0 0]A
[circuit-leitung_garage] DEBUG 2024/09/23 11:14:44 power: 4656W
[circuit-leitung_garage] DEBUG 2024/09/23 11:14:44 current: 6.7A
[site  ] DEBUG 2024/09/23 11:14:45 pv power: 3042W
[site  ] DEBUG 2024/09/23 11:14:45 battery soc: 87%
[site  ] DEBUG 2024/09/23 11:14:45 battery power: 2125W
[site  ] DEBUG 2024/09/23 11:14:45 grid meter: -27W
[site  ] DEBUG 2024/09/23 11:14:46 site power: 2198W
[lp-1  ] DEBUG 2024/09/23 11:14:46 charge total import: 823.306kWh
[lp-1  ] DEBUG 2024/09/23 11:14:46 charger status: C
[lp-1  ] DEBUG 2024/09/23 11:14:46 charge start energy: 823.306kWh
[lp-1  ] INFO 2024/09/23 11:14:46 start charging ->
[lp-1  ] DEBUG 2024/09/23 11:14:46 wake-up timer: stop
[pushover] DEBUG 2024/09/23 11:14:46 sending to ***
[lp-1  ] DEBUG 2024/09/23 11:14:46 soc estimated: 81.03% (vehicle: 81.00%)
[lp-1  ] DEBUG 2024/09/23 11:14:46 vehicle soc: 81%
[lp-1  ] DEBUG 2024/09/23 11:14:46 vehicle soc limit: 100%
[lp-1  ] DEBUG 2024/09/23 11:14:46 vehicle range: 321km
[lp-1  ] DEBUG 2024/09/23 11:14:46 pv charge current: 0A = 7A + -9.56A (2198W @ 1p)
[lp-1  ] DEBUG 2024/09/23 11:14:46 projected site power 2198W >= -200W disable threshold
[lp-1  ] DEBUG 2024/09/23 11:14:46 pv disable in 0s
[lp-1  ] DEBUG 2024/09/23 11:14:46 pv disable timer elapsed
[circuit-leitung_garage] TRACE 2024/09/23 11:14:46 validate current: 6.7A + (7A -> 0A) <= 32A ok
[circuit-leitung_garage] TRACE 2024/09/23 11:14:46 validate power: 4656W + (4656W -> 0W) <= 20000W ok
[lp-1  ] DEBUG 2024/09/23 11:14:46 charger disable
[lp-1  ] DEBUG 2024/09/23 11:14:46 wake-up timer: stop
[site  ] DEBUG 2024/09/23 11:15:14 ----
[lp-1  ] DEBUG 2024/09/23 11:15:14 charge power: 0W
[lp-1  ] DEBUG 2024/09/23 11:15:14 charge currents: [0 0 0]A
[lp-2  ] DEBUG 2024/09/23 11:15:14 charge power: 0W
[lp-2  ] DEBUG 2024/09/23 11:15:14 charge currents: [0 0 0]A
[circuit-leitung_garage] DEBUG 2024/09/23 11:15:14 power: 0W
[circuit-leitung_garage] DEBUG 2024/09/23 11:15:14 current: 0A
[site  ] DEBUG 2024/09/23 11:15:15 pv power: 3389W
[site  ] DEBUG 2024/09/23 11:15:15 battery soc: 87%
[site  ] DEBUG 2024/09/23 11:15:15 battery power: -3040W
[site  ] DEBUG 2024/09/23 11:15:15 grid meter: 122W
[site  ] DEBUG 2024/09/23 11:15:16 site power: 222W
[lp-2  ] DEBUG 2024/09/23 11:15:16 charge total import: 0.060kWh
[lp-2  ] DEBUG 2024/09/23 11:15:16 charger status: A
[circuit-leitung_garage] TRACE 2024/09/23 11:15:16 validate current: 0A + (0A -> 0A) <= 32A ok
[circuit-leitung_garage] TRACE 2024/09/23 11:15:16 validate power: 0W + (0W -> 0W) <= 20000W ok
[site  ] DEBUG 2024/09/23 11:15:44 ----
[lp-1  ] DEBUG 2024/09/23 11:15:44 charge power: 0W
[lp-1  ] DEBUG 2024/09/23 11:15:44 charge currents: [0 0 0]A
[lp-2  ] DEBUG 2024/09/23 11:15:44 charge power: 0W
[lp-2  ] DEBUG 2024/09/23 11:15:44 charge currents: [0 0 0]A
[circuit-leitung_garage] DEBUG 2024/09/23 11:15:44 power: 0W
[circuit-leitung_garage] DEBUG 2024/09/23 11:15:44 current: 0A
[site  ] DEBUG 2024/09/23 11:15:45 pv power: 2863W
[site  ] DEBUG 2024/09/23 11:15:45 battery soc: 88%
[site  ] DEBUG 2024/09/23 11:15:45 battery power: -2604W
[site  ] DEBUG 2024/09/23 11:15:45 grid meter: -25W
[site  ] DEBUG 2024/09/23 11:15:46 site power: -2529W
[lp-1  ] DEBUG 2024/09/23 11:15:46 charge total import: 823.306kWh
[lp-1  ] DEBUG 2024/09/23 11:15:46 charger status: B
[lp-1  ] DEBUG 2024/09/23 11:15:46 charge final energy: 0.029kWh
[lp-1  ] INFO 2024/09/23 11:15:46 stop charging <-
[lp-1  ] DEBUG 2024/09/23 11:15:46 pv timer reset
[lp-1  ] DEBUG 2024/09/23 11:15:46 pv timer inactive
[pushover] DEBUG 2024/09/23 11:15:46 sending to ***
[lp-1  ] DEBUG 2024/09/23 11:15:46 charge total import: 823.306kWh
[lp-1  ] DEBUG 2024/09/23 11:15:47 soc estimated: 81.03% (vehicle: 81.00%)
[lp-1  ] DEBUG 2024/09/23 11:15:47 vehicle soc: 81%
[lp-1  ] DEBUG 2024/09/23 11:15:47 vehicle soc limit: 100%
[lp-1  ] DEBUG 2024/09/23 11:15:47 vehicle range: 321km
[lp-1  ] DEBUG 2024/09/23 11:15:47 pv charge current: 11A = 0A + 11A (-2529W @ 1p)
[lp-1  ] DEBUG 2024/09/23 11:15:47 site power -2529W <= 0W enable threshold
[lp-1  ] DEBUG 2024/09/23 11:15:47 pv enable timer start: 1m0s
[lp-1  ] DEBUG 2024/09/23 11:15:47 pv enable in 1m0s
[circuit-leitung_garage] TRACE 2024/09/23 11:15:47 validate current: 0A + (0A -> 0A) <= 32A ok
[circuit-leitung_garage] TRACE 2024/09/23 11:15:47 validate power: 0W + (0W -> 0W) <= 20000W ok

What type of operating system are you running?

Docker container

Nightly build

  • I have verified that the issue is reproducible with the latest nightly build