Notifications
You must be signed in to change notification settings - Fork 31
Open
Description
I have a setup with a USB hub, to which multiple serial devices are attached. I listed them below. I usually have 3 instances open, which I marked with an arrow.
COM3 ---- ---- Standard Serial over Bluetooth link (COM3) [SPPS De]
COM4 ---- ---- Standard Serial over Bluetooth link (COM4) [Bluetooth Peripheral Device]
COM6 1366 0105 USB Serial Device (COM6) [CDC] <--
COM11 1366 0105 USB Serial Device (COM11) [CDC] <--
COM24 0403 6011 USB Serial Port (COM24)
COM25 0403 6011 USB Serial Port (COM25)
COM26 0403 6011 USB Serial Port (COM26) <--
COM27 0403 6011 USB Serial Port (COM27)
The last four COM ports all belong to the same FTDI4232 Mini Module.
Whenever I reconnect any of the separate devices, recovery is all fine. However, when I disconnect the complete USB hub (causing the removal of all of above COM ports, except the Bluetooth ones), the SimplySerial instance using COM26 throws this exception:
Unhandled Exception: System.Management.ManagementException: Not found
at System.Management.ManagementException.ThrowWithExtendedInfo(ManagementStatus errorCode)
at System.Management.ManagementObject.InvokeMethod(String methodName, ManagementBaseObject inParameters, InvokeMethodOptions options)
at System.Management.ManagementObject.InvokeMethod(String methodName, Object[] args)
at SimplySerial.ComPortManager.GetPorts()
at SimplySerial.SimplySerial.Main(String[] args)
[process exited with code 3762504530 (0xe0434352)]
When I restart the instance it is fine again.
SimplySerial version 0.9.0
Installation Type : System
Installation Path : C:\Program Files (x86)\SimplySerial
Board Data File : 2025-03-04T20-57-17.992214
Reactions are currently unavailable