lines changed Original file line number Diff line number Diff line change 286286
287287Battery bounds available for use: -100kW to 100kW
288288
289+ ##### Shifting or Limiting
290+
289291| pri | available bounds | req bounds | req power | s/l | power in range | cumulative power |
290292|-----|------------------|----------------|-----------|--------|----------------|------------------|
291293| 7 | -100kW .. 100kW | None | 10kW | shifts | 10kW | 10kW |
298300| 0 | -52kW .. 18kW | -40kW .. -10kW | -10kW | limits | -10kW | -28kW |
299301| | | | | | target power | -28kW |
300302
303+ ##### Shifting and Limiting
304+
305+ | pri | available bounds | req bounds | req power | power in range | cumulative power |
306+ |-----|------------------|----------------|-----------|----------------|------------------|
307+ | 7 | -100kW .. 100kW | None | 10kW | 10kW | 10kW |
308+ | 6 | -110kW .. 90kW | -110kW .. 80kW | 10kW | 10kW | 20kW |
309+ | 5 | -120kW .. 70kW | -100kW .. 80kW | 80kW | 70kW | 90kW |
310+ | 4 | -190kW .. 0kW | None | -120kW | -120kW | -30kW |
311+ | 3 | -70kW .. 120kW | None | 60kW | 60kW | 30kW |
312+ | 2 | -130kW .. 60kW | -40kW .. 30kW | 20kW | 20kW | 50kW |
313+ | 1 | -60kW .. 10kW | None | 12kW | 10kW | 60kW |
314+ | 0 | -70kW .. 0kW | -40kW .. -10kW | -10kW | -10kW | 50kW |
315+ | | | | | target power | 50kW |
316+
301317In this example, there are some shifting and some limiting actors, and each of
302318them affect the lower priority actors in the same patterns mentioned above.
303319""" # noqa: D205, D400