src/frequenz/sdk/microgrid/__init__.py

Lines changed: 115 additions & 60 deletions
Original file line numberDiff line numberDiff line change
@@ -186,6 +186,11 @@
186186
method available for all pools, which also streams the bounds that an actor
187187
should comply with, based on its priority.
188188
189+
### Working with other actors to control Batteries
190+
191+
This section describes the details of the power manager's reconciliation
192+
algorithm for controlling batteries.
193+
189194
#### Adding the power proposals of individual actors
190195
191196
When an actor A calls the `propose_power` method with a power, the proposed
@@ -201,35 +206,39 @@
201206
202207
*Example 1*: Battery bounds available for use: -100kW to 100kW
203208
204-
| Actor | Priority | System Bounds | Requested Bounds | Requested | Adjusted | Aggregate |
205-
| | | | | Power | Power | Power |
206-
|-------|----------|-----------------|------------------|-----------|--------------|-----------|
207-
| A | 3 | -100kW .. 100kW | None | 20kW | 20kW | 20kW |
208-
| B | 2 | -120kW .. 80kW | None | 50kW | 50kW | 70kW |
209-
| C | 1 | -170kW .. 30kW | None | 50kW | 30kW | 100kW |
210-
| | | | | | target power | 100kW |
209+
| Actor | Priority | Available Bounds | Requested Bounds | Requested Power | Adjusted Power | Aggregate Power |
210+
|------:|---------:|-----------------:|-----------------:|----------------:|---------------:|----------------:|
211+
| A | 3 | -100kW .. 100kW | None | 20kW | 20kW | 20kW |
212+
| B | 2 | -120kW .. 80kW | None | 50kW | 50kW | 70kW |
213+
| C | 1 | -170kW .. 30kW | None | 50kW | 30kW | 100kW |
214+
| | | | | | target power | 100kW |
215+
216+
1. Actor A sees the full system: Available Bounds = `-100kW .. 100kW`. It
217+
proposes a power of `20kW`, but no bounds.
218+
219+
2. This becomes the operating point for actor B, so actor B sees bounds shifted
220+
by A's proposal = `-120kW .. 80kW`. It can operate only in this range.
221+
222+
3. Actor B proposes a power of `50kW` on this shifted range, and if this is
223+
applied on to the original bounds (aka shift the bounds back to the original
224+
range), it would be `20kW + 50kW = 70kW`.
211225
212-
Actor A proposes a power of `20kW`, but no bounds. In this case, actor B sees
213-
bounds shifted by A's proposal. Actor B proposes a power of `50kW` on this
214-
shifted range, and if this is applied on to the original bounds (aka shift the
215-
bounds back to the original range), it would be `20kW + 50kW = 70kW`.
226+
4. So Actor C sees bounds shifted by `70kW` from the original bounds, and sets
227+
`50kW` on this shifted range, but it can't exceed `30kW`, so its request gets
228+
limited to 30kW.
216229
217-
So Actor C sees bounds shifted by `70kW` from the original bounds, and sets
218-
`50kW` on this shifted range, but it can't exceed `30kW`, so its request gets
219-
limited to 30kW. Shifting this back by `70kW`, the target power is calculated
220-
to be `100kW`.
230+
5. Shifting this back by `70kW`, the target power is calculated to be `100kW`.
221231
222232
Irrespective of what any actor sets, the final power won't exceed the available
223233
battery bounds.
224234
225235
*Example 2*:
226236
227-
| Actor | Priority | System Bounds | Requested Bounds | Requested | Adjusted | Aggregate |
228-
| | | | | Power | Power | Power |
229-
|-------|----------|-----------------|------------------|-----------|--------------|-----------|
230-
| A | 3 | -100kW .. 100kW | None | 20kW | 20kW | 20kW |
231-
| B | 2 | -120kW .. 80kW | None | -20kW | -20kW | 0kW |
232-
| | | | | | target power | 0kW |
237+
| Actor | Priority | Available Bounds | Requested Bounds | Requested Power | Adjusted Power | Aggregate Power |
238+
|------:|---------:|-----------------:|-----------------:|----------------:|---------------:|----------------:|
239+
| A | 3 | -100kW .. 100kW | None | 20kW | 20kW | 20kW |
240+
| B | 2 | -120kW .. 80kW | None | -20kW | -20kW | 0kW |
241+
| | | | | | target power | 0kW |
233242
234243
Actors with exactly opposite requests cancel each other out.
235244
@@ -241,39 +250,39 @@
241250
242251
*Example 1*: Battery bounds available for use: -100kW to 100kW
243252
244-
| Actor | Priority | System Bounds | Requested Bounds | Requested | Adjusted | Aggregate |
245-
| | | | | Power | Power | Power |
246-
|-------|----------|-----------------|------------------|-----------|--------------|-----------|
247-
| A | 3 | -100kW .. 100kW | -20kW .. 100kW | 50kW | 40kW | 50kW |
248-
| B | 2 | -70kW .. 50kW | -90kW .. 0kW | -10kW | -10kW | 40kW |
249-
| C | 1 | -60kW .. 10kW | None | -20kW | -20kW | 20kW |
250-
| | | | | | target power | 20kW |
253+
| Actor | Priority | Available Bounds | Requested Bounds | Requested Power | Adjusted Power | Aggregate Power |
254+
|------:|---------:|-----------------:|-----------------:|----------------:|---------------:|----------------:|
255+
| A | 3 | -100kW .. 100kW | -20kW .. 100kW | 50kW | 50kW | 50kW |
256+
| B | 2 | -70kW .. 50kW | -90kW .. 0kW | -10kW | -10kW | 40kW |
257+
| C | 1 | -60kW .. 10kW | None | -20kW | -20kW | 20kW |
258+
| | | | | | target power | 20kW |
251259
252-
Actor A with the highest priority has the entire battery bounds available to it.
253-
It sets limited bounds of -20kW .. 100kW, and proposes a power of 50kW.
260+
1. Actor A with the highest priority has the entire battery bounds available to
261+
it. It sets limited bounds of `-20kW .. 100kW`, and proposes a power of
262+
`50kW`.
254263
255-
Actor B sees Actor A's limit of -20kW..100kW shifted by 50kW as -70kW..50kW, and
256-
can only propose powers within this range, which will get added (shifted back)
257-
to Actor A's proposed power.
264+
2. Actor B's operating point is now `50kW`. So, Actor B sees Actor A's limit of
265+
`-20kW..100kW` shifted by `50kW` as `-70kW..50kW`, and can only operate
266+
within this range.
258267
259-
Actor B tries to limit the bounds of actor C to -90kW .. 0kW, but it can only
260-
operate in the -70kW .. 50kW range because of bounds set by actor A, so its
261-
requested bounds get restricted to -70kW .. 0kW.
268+
3. Actor B tries to limit the bounds of actor C to `-90kW .. 0kW`, but it
269+
doesn't have access to that full range and can only operate in the
270+
`-70kW .. 50kW` range, so its specified bounds get restricted to
271+
`-70kW .. 0kW`.
262272
263-
Actor C sees this as -60kW .. 10kW, because it gets shifted by Actor B's
264-
proposed power of -10kW.
273+
4. Actor C sees this as `-60kW .. 10kW`, because it gets shifted by Actor B's
274+
proposed power of `-10kW`.
265275
266-
Actor C proposes a power within its bounds and the proposals of all the actors
267-
are added to get the target power.
276+
5. Actor C proposes a power within its bounds and the proposals of all the actors
277+
are added to get the target power.
268278
269279
*Example 2*:
270280
271-
| Actor | Priority | System Bounds | Requested Bounds | Requested | Adjusted | Aggregate |
272-
| | | | | Power | Power | Power |
273-
|-------|----------|-----------------|------------------|-----------|--------------|-----------|
274-
| A | 3 | -100kW .. 100kW | -20kW .. 100kW | 50kW | 50kW | 50kW |
275-
| B | 2 | -70kW .. 50kW | -90kW .. 0kW | -90kW | -70kW | -20kW |
276-
| | | | | | target power | -20kW |
281+
| Actor | Priority | Available Bounds | Requested Bounds | Requested Power | Adjusted Power | Aggregate Power |
282+
|------:|---------:|-----------------:|-----------------:|----------------:|---------------:|----------------:|
283+
| A | 3 | -100kW .. 100kW | -20kW .. 100kW | 50kW | 50kW | 50kW |
284+
| B | 2 | -70kW .. 50kW | -90kW .. 0kW | -90kW | -70kW | -20kW |
285+
| | | | | | target power | -20kW |
277286
278287
When an actor requests a power that's outside its available bounds, the closest
279288
available power is used.
@@ -282,19 +291,65 @@
282291
283292
Battery bounds available for use: -100kW to 100kW
284293
285-
| Priority | System Bounds | Requested Bounds | Requested | Adjusted | Aggregate |
286-
| | | | Power | Power | Power |
287-
|----------|-------------------|------------------|-----------|--------------|-----------|
288-
| 7 | -100 kW .. 100 kW | None | 10 kW | 10 kW | 10 kW |
289-
| 6 | -110 kW .. 90 kW | -110 kW .. 80 kW | 10 kW | 10 kW | 20 kW |
290-
| 5 | -120 kW .. 70 kW | -100 kW .. 80 kW | 80 kW | 70 kW | 90 kW |
291-
| 4 | -170 kW .. 0 kW | None | -120 kW | -120 kW | -30 kW |
292-
| 3 | -50 kW .. 120 kW | None | 60 kW | 60 kW | 30 kW |
293-
| 2 | -110 kW .. 60 kW | -40 kW .. 30 kW | 20 kW | 20 kW | 50 kW |
294-
| 1 | -60 kW .. 10 kW | -50 kW .. 40 kW | 25 kW | 10 kW | 60 kW |
295-
| 0 | -60 kW .. 0 kW | None | 12 kW | 0 kW | 60 kW |
296-
| -1 | -60 kW .. 0 kW | -40 kW .. -10 kW | -10 kW | -10 kW | 50 kW |
297-
| | | | | Target Power | 50 kW |
294+
| Priority | Available Bounds | Requested Bounds | Requested Power | Adjusted Power | Aggregate Power |
295+
|---------:|------------------:|-----------------:|----------------:|---------------:|----------------:|
296+
| 7 | -100 kW .. 100 kW | None | 10 kW | 10 kW | 10 kW |
297+
| 6 | -110 kW .. 90 kW | -110 kW .. 80 kW | 10 kW | 10 kW | 20 kW |
298+
| 5 | -120 kW .. 70 kW | -100 kW .. 80 kW | 80 kW | 70 kW | 90 kW |
299+
| 4 | -170 kW .. 0 kW | None | -120 kW | -120 kW | -30 kW |
300+
| 3 | -50 kW .. 120 kW | None | 60 kW | 60 kW | 30 kW |
301+
| 2 | -110 kW .. 60 kW | -40 kW .. 30 kW | 20 kW | 20 kW | 50 kW |
302+
| 1 | -60 kW .. 10 kW | -50 kW .. 40 kW | 25 kW | 10 kW | 60 kW |
303+
| 0 | -60 kW .. 0 kW | None | 12 kW | 0 kW | 60 kW |
304+
| -1 | -60 kW .. 0 kW | -40 kW .. -10 kW | -10 kW | -10 kW | 50 kW |
305+
| | | | | Target Power | 50 kW |
306+
307+
### Working with other actors to control PV inverters and EV chargers
308+
309+
The power manager reconciles power proposals for PV inverters and EV chargers
310+
similarly to batteries, but with one key difference:
311+
312+
There is no shifting of operating point between actors, and the powers are not
313+
added together.
314+
315+
Higher priority actors can strictly limit the bounds available to lower priority
316+
actors, but the power proposals by lower priority actors take precedence, as
317+
long as they are within the bounds set by higher priority actors.
318+
319+
This is because PV inverters can only produce power (negative power according to
320+
the PSC), and EV chargers can only consume power (positive power according to
321+
the PSC), and shifting bounds would make ranges available to actors that a PV
322+
inverter or EV charger can't operate in.
323+
324+
*A PV pool Example*
325+
326+
| Actor | Priority | Available Bounds | Requested Bounds | Requested Power | Adjusted Power |
327+
|------:|---------:|-----------------:|-----------------:|----------------:|---------------:|
328+
| A | 4 | -100kW .. 0W | -90kW .. 0kW | -20kW | -20kW |
329+
| B | 3 | -90kW .. 0kW | -75kW .. -20kW | -50kW | -50kW |
330+
| C | 2 | -75kW .. -20kW | None | -100kW | -75kW |
331+
| D | 1 | -75kW .. -20kW | -60kW .. -60kW | -60kW | -60kW |
332+
| E | 0 | -60kW .. -60kW | None | -20kW | -60kW |
333+
| | | | | Final Power | -60kW |
334+
335+
1. Actor A with the highest priority has access to the entire range of the PV
336+
inverters. In this case `-100kW .. 0W`.
337+
338+
2. It wants to limit production to a maximum of `-90kW`, so it sets bounds of
339+
`-90kW .. 0W`. It also proposes a power of `-20kW`. If there are no lower
340+
priority actors, that power will get set to the inverters. But here, it gets
341+
*overridden* by lower priority actors.
342+
343+
3. Actor B limits the bounds further, and proposes its preferred power.
344+
345+
4. Actor C proposes `-100kW`, which is outside of what Actor B has allowed, so it
346+
gets clamped to `-75kW`, which is the closest Actor C can get to its requested
347+
power in its available range of `-75kW .. -20kW`.
348+
349+
5. Actor D wants exactly `-60kW`, so it clamps the bounds to `-60kW .. -60kW`, and
350+
sets `-60kW`, making sure Actor E or other lower priority actors can't change
351+
the power further.
352+
298353
299354
## Withdrawing power proposals
300355
@@ -311,7 +366,7 @@
311366
| Batteries | Zero |
312367
| PV | Max production (Min power according to PSC) |
313368
| EV Chargers | Max consumption (Max power according to PSC) |
314-
""" # noqa: D205, D400
369+
""" # noqa: D205, D400, E501
315370

316371
from datetime import timedelta
317372

0 commit comments