committed
Add test for inverter data parsing from the microgrid API
Signed-off-by: Sahas Subramanian <[email protected]>
1 parent b319e92 commit 40b3b97

File tree

1 file changed

+66
-1
lines changed

1 file changed

+66
-1
lines changed

tests/microgrid/test_component_data.py

Lines changed: 66 additions & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -6,12 +6,77 @@
66
from datetime import datetime, timezone
77

88
import pytest
9+
from frequenz.api.common import metrics_pb2
10+
from frequenz.api.common.metrics import electrical_pb2
11+
from frequenz.api.microgrid import inverter_pb2, microgrid_pb2
12+
from google.protobuf import timestamp_pb2
913

10-
from frequenz.sdk.microgrid.component import ComponentData
14+
from frequenz.sdk.microgrid.component import ComponentData, InverterData
15+
16+
# pylint: disable=no-member
1117

1218

1319
def test_component_data_abstract_class() -> None:
1420
"""Verify the base class ComponentData may not be instantiated."""
1521
with pytest.raises(TypeError):
1622
# pylint: disable=abstract-class-instantiated
1723
ComponentData(0, datetime.now(timezone.utc)) # type: ignore
24+
25+
26+
def test_inverter_data() -> None:
27+
"""Verify the constructor for the InverterData class."""
28+
seconds = 1234567890
29+
30+
raw = microgrid_pb2.ComponentData(
31+
id=5,
32+
ts=timestamp_pb2.Timestamp(seconds=seconds),
33+
inverter=inverter_pb2.Inverter(
34+
state=inverter_pb2.State(
35+
component_state=inverter_pb2.COMPONENT_STATE_DISCHARGING
36+
),
37+
errors=[inverter_pb2.Error(msg="error message")],
38+
data=inverter_pb2.Data(
39+
dc_battery=None,
40+
dc_solar=None,
41+
temperature=None,
42+
ac=electrical_pb2.AC(
43+
frequency=metrics_pb2.Metric(value=50.1),
44+
power_active=metrics_pb2.Metric(
45+
value=100.2,
46+
system_exclusion_bounds=metrics_pb2.Bounds(
47+
lower=-501.0, upper=501.0
48+
),
49+
system_inclusion_bounds=metrics_pb2.Bounds(
50+
lower=-51000.0, upper=51000.0
51+
),
52+
),
53+
phase_1=electrical_pb2.AC.ACPhase(
54+
current=metrics_pb2.Metric(value=12.3),
55+
),
56+
phase_2=electrical_pb2.AC.ACPhase(
57+
current=metrics_pb2.Metric(value=23.4),
58+
),
59+
phase_3=electrical_pb2.AC.ACPhase(
60+
current=metrics_pb2.Metric(value=34.5),
61+
),
62+
),
63+
),
64+
),
65+
)
66+
67+
inv_data = InverterData.from_proto(raw)
68+
assert inv_data.component_id == 5
69+
assert inv_data.timestamp == datetime.fromtimestamp(seconds, timezone.utc)
70+
assert ( # pylint: disable=protected-access
71+
inv_data._component_state == inverter_pb2.COMPONENT_STATE_DISCHARGING
72+
)
73+
assert inv_data._errors == [ # pylint: disable=protected-access
74+
inverter_pb2.Error(msg="error message")
75+
]
76+
assert inv_data.frequency == pytest.approx(50.1)
77+
assert inv_data.active_power == pytest.approx(100.2)
78+
assert inv_data.current_per_phase == pytest.approx((12.3, 23.4, 34.5))
79+
assert inv_data.active_power_inclusion_lower_bound == pytest.approx(-51000.0)
80+
assert inv_data.active_power_inclusion_upper_bound == pytest.approx(51000.0)
81+
assert inv_data.active_power_exclusion_lower_bound == pytest.approx(-501.0)
82+
assert inv_data.active_power_exclusion_upper_bound == pytest.approx(501.0)

0 commit comments

Comments