@@ -36,19 +36,21 @@ Siemens scanners come with a useful program called ``ideacmdtool`` that can conf
36
36
37
37
Configure the default settings (these steps should be performed **BEFORE** registering a patient):
38
38
39
+
.. image:: network_online_export.jpg
40
+
39
41
4. Enter ``4`` to go to the "Online export defaults" menu
40
42
5. Enter ``1`` and set "Target port" to ``-1``
41
43
6. Enter ``3`` and set "Target path" to ``y:`` (or whatever path you mounted the SAMBA folder on)
42
44
7. Enter ``8`` to set ``SendBuffered`` to ``OFF``
43
45
8. Enter ``q`` to go back to the main ``ideacmdtool`` menu
44
46
45
-
.. image:: network_online_export.jpg
46
47
47
48
Configure the session settings (these steps should be performed **AFTER** registering a patient, since these flags get reset every time you register a new patient):
48
49
50
+
.. image:: network_switches.jpg
51
+
49
52
9. Enter ``5`` to go to the "Switches" menu
50
53
10. Enter ``8`` to set ``SendIMA`` to ``ON``
51
54
11. Enter ``q`` to go back to the main ``ideacmdtool`` menu