Plasma Up/Dwn signals possibly reversed.  #15

@DBS3262

Description

@DBS3262

Hey Terje,

Having a problem with Plasma up/down mode.

Configuration: plasma mode = Up/Dwn. Originally configured "plasma up" = 3 and "plasma down" = 2. Inverted I/O ports 2,3. THC wired wired with "up" to ST3 and "down" to ST2 on E5X controller.

Im testing with Proma THC 150 in test mode. This simulates a floating voltage and sends short up and down signals. THC has torch up and down indicators so the user knows what the intended output should be.

When testing with the above configuration, controller was going up during down signal form THC and down during Up signal from THC. I reassigned I/O ports, Cutter down = 3, Cutter up =2. This corrected controller motor output to match proma THC; However, plasma fly out indicators continue to show reversed output.

On a side note, G65 macros seem to be working great. I couldn't find integration for ohmic probe yet. I wrote a G65 macro for using a relay to accomplish this. Would be happy to post the details if you think that would be helpful to other users.