This configuration lets you change your Multiplus device Switch state (on / off / charger only / inverter only) with a physical switch.
Follow the switch configuration page to add a switch named Inverter_switch.
Access Node RED and import Inverter switch flow :
The Translate node translates the switch value into the desired Multiplus Switch value. By default, it is :
| Inverter switch value | Multiplus switch value |
|---|---|
| 6 (open = off position) | 3 (On) |
| 7 (closed = on position) | 1 (Charger only) |
Double-click on the Multiplus switch node to see the allowed values. Change the Translate node as desired.
This configuration allows you to stop battery charge while keeping 220v on without activating the inverter, hence its name, 220V "pass through" Multiplus.
In detail, it changes the DVCC Limit charge current value to -1 (= unlimited charge) or 0 (= no charge) with a physical switch.
Follow the switch configuration page to add a switch named Passthrough_switch.
Access Node RED and import Passthrough switch flow :
The Translate node translates the switch value into the desired DVCC Limit charge current value. By default, it is :
| Passthrough switch value | DVCC Limit charge current value |
|---|---|
| 6 (open = off position) | -1 (Unlimited) |
| 7 (closed = on position) | 0 (0A) |