Reverse-engineering notes

What is actually known about the JNT-EVCD2-EU charger and the S-Charge protocol, and how each fact was established. Written so that a future session does not repeat work already done — including the dead ends.

Every claim is tagged:

  • [confirmed] — directly observed, reproducible
  • [inferred] — strong evidence, but one step removed from observation
  • [untested] — hypothesis worth testing, not yet tested

1. Hardware

Model JNT-EVCD2-EU, Joint Tech / Joint Charging
Software version E3P3_H_1.1.1_R5190 (reported as sVersion)
Hardware version E3P3_V1.00 (reported as hVersion)
Connectors 2 × Type 2 socket (connectorMain, connectorVice)
Rating 2 × 22 kW, 64 A total across both sockets
Supply 400 V AC three-phase (evsePhase: "threephase")

[confirmed] Versions and connector layout come from the charger's own DeviceData message. [inferred] Ratings come from the vendor's published specification for the EVC D2 line, not from the device.

The vendor advertises OCPP 1.6J for this product line. See §5 — we could not find any way to reach it on this unit.

2. Network behaviour

[confirmed] The charger listens on no TCP port at all. A full scan of all 65535 ports returns only closed or filtered — nothing open:

nmap -Pn -p- --min-rate 3000 192.168.1.134
# All 65535 scanned ports are filtered (58351) or closed (7184)

Ports answer with RST rather than being dropped, so this is not a firewall hiding services. Consequences: there is no local web UI, no telnet, no SSH, and no configuration surface reachable over the LAN.

[confirmed] The charger is purely a client. It discovers a server via a UDP broadcast to port 3050 and then opens a WebSocket back to the advertised address. This is the mechanism scharge_server.py implements.

[inferred] No cloud connectivity. Observed by Wireshark before these notes were written, and consistent with the app offering no remote functionality. Not exhaustively verified — a capture taken on a LAN host cannot see charger → internet traffic on a switched network, so a router-side capture would be needed to state this with certainty.

[confirmed] There is no AP mode. The charger pairs with the app over Bluetooth LE; the app's WiFiConfig string and its bundled flutter_blue plugin corroborate BLE-based WiFi provisioning.

Net result: every configuration path goes through the app, over BLE for provisioning and over the local WebSocket protocol thereafter.

3. The S-Charge app

Package com.yill.s_charge
Framework Flutter (Dart AOT)
Notable libs flutter_blue (BLE), Sentry (crash reporting)

[confirmed] The app logic lives in lib/arm64-v8a/libapp.so (≈7.7 MB Dart AOT snapshot). classes.dex holds only the Android shim and plugins.

Consequence for future work: jadx, apktool, and openjdk are of no use here — they decompile the shim, not the protocol. Useful analysis is strings on libapp.so plus the Flutter asset names. Going deeper means reversing the Dart AOT snapshot (e.g. blutter), which was judged not worth the effort relative to testing hypotheses directly against the charger.

unzip -o base.apk -d base                       # Android shim, plugins
unzip -o split_config.arm64_v8a.apk -d arm64    # the real payload
strings -n 4 arm64/lib/arm64-v8a/libapp.so > libapp.strings

The string pool is hash-ordered, so neighbouring strings are unrelated — searching by vocabulary works, dumping surrounding lines does not.

4. Protocol findings

4.1 Message set

[confirmed] The app uses the same message set already implemented in src/messages.py and src/messages_rx.py: UDPHandShake, HandShake, Ack, Authorize (outgoing) and DeviceData, SynchroStatus, SynchroData, NWireToDics (incoming).

[confirmed] There is one more incoming action the integration does not know about — Heartbeat, observed in a live capture of 210 messages:

{"messageTypeId":"5","uniqueId":"194375","action":"Heartbeat",
 "payload":{"chargeBoxSN":"2100322207300573"}}

It carries nothing but the serial and arrives roughly every 12 s. parse_json returns None for it, so it is acked and then discarded, which is harmless — but it is a free liveness signal. Heartbeats stopping is a much faster and more reliable death detector than waiting for TCP to give up, which is what the connection currently relies on (ping_timeout=float("inf") in server_loop disables the websockets keepalive timeout).

Observed inbound mix over ~2 minutes idle: DeviceData 35, SynchroStatus 32, SynchroData 19, Heartbeat 9, NWireToDics 1. Note DeviceData arrives constantly — it is only the value of totalPower inside it that waits for a session to end.

[confirmed] A sweep of the app's string pool for further action names found nothing protocol-shaped — only Flutter framework classes and WiFiConfig. There is no hidden "set current" action. Changing the current almost certainly means re-sending Authorize with purpose: "Start", which matches the observed behaviour that pressing Charge again applies a new current.

4.2 chargeStatus values — important

[inferred, high confidence] chargeStatus takes at least six values:

idle    wait    charging    finish    fault    reserve

Evidence: the app ships one icon per state, and the three names that overlap with known wire values match them exactly, so the other two follow the same pattern:

assets/charge-wait.png       assets/charge-charging.png   assets/charge-finish.png
assets/charge-fault.png      assets/charge-reserve.png
assets/charge-off.png        assets/charge-on.png          # device power, not chargeStatus

idle additionally appears in the string pool.

This breaks the integration today. ChargeStatusEnum in src/charger_state.py defines only wait, charging, finish, idle. A fault or reserve status raises ValueError inside ChargerParam.update, which propagates out of process_websocket uncaught — permanently wedging the connection until restart. See known-issues.md issue 1; this is one of its confirmed root causes.

Treat the list as a lower bound, not a closed set. The parser should tolerate unknown values rather than enumerate them — which is what _missing_ on ChargeStatusEnum now does.

A live capture of 210 messages with nothing plugged in showed only idle and finish, so fault and reserve have still not been seen on the wire. They remain inferred.

4.3 electricWork persists after a session ends

[confirmed] When a session finishes, electricWork keeps reporting that session's energy — it is not cleared. Captured live with nothing plugged in:

"connectorVice":{"voltage":"403.64","current":"0.00","power":"0.00",
                 "electricWork":"5.00","chargingTime":"2:33:15"}

with chargeStatus already finish and totalPower already grown to include those 5 kWh. So electricWork may only ever be added to totalPower while chargeStatus is charging; outside a session it is a stale leftover and adding it would double-count. This is the mechanism behind the second entry in known-issues.md, and it is why ChargerState.total_charged_energy() anchors the session to the total observed when it started.

4.4 Scheduled charging ("reserve")

[confirmed] The app has a scheduled-charging feature. Its payload keys appear in the string pool:

reservationId   reserveBegin   reserveEnd   reserveConnector   reserveCurrent

with UI text "Reserve to Charge", "Cancel Reservation", "Notice: Plug in the connector, and wait to start at the reserved time".

[untested] Reservations are probably sent as Authorize with purpose: "Reserve" — bare Reserve and Reserved sit in the string pool alongside Start and Stop, and no separate action name exists.

Correction to an earlier assumption: reserveCurrent (present in SynchroStatus and already parsed) belongs to this feature — the current for a booked future session. It should not be assumed to be the live setpoint echo for an active charge. Whether it also tracks the current requested by a normal Start is [untested] and worth checking, since a real setpoint echo would be a much better thing to verify against than the measured current.

5. OCPP — investigated and dropped

[confirmed] No way to point this unit at an OCPP backend was found:

  • no OCPP settings in the app;
  • no local web UI (no open TCP port);
  • no AP-mode configuration page;
  • no observed cloud connection that could be DNS-redirected.

[inferred] The firmware is probably an app/cloud SKU without a usable OCPP client, despite the product line advertising OCPP 1.6J. The H in E3P3_H_1.1.1_R5190 may denote a home build. Untested route if this is ever revisited: ask Joint Tech directly for the OCPP configuration procedure or firmware, quoting model, serial, and firmware version.

tools/ holds a permissive OCPP 1.6j probe server built during this investigation. It is verified working against a simulated charge point and is kept for the case where OCPP firmware becomes available. See tools/README.md.

5a. Setting the charging current — measured

Measured live on 2026-08-13 against connector 2 with a car attached, sending Authorize with purpose: "Start" directly (raw data in artifacts/current_experiment.csv).

[confirmed] The first Start after a session ends ignores the requested current. From chargeStatus: finish, Start at 6 A was accepted (result=True) and the car then drew 30.95 A / 21.2 kW — full rate — for the whole 75 s step.

[confirmed] A Start re-sent during an active session does apply the current. Requesting 8 A while already charging moved the draw from 30.93 A to 7.17 A within about 4 seconds. Requesting 10 A then moved it to 8.88 A. This is the mechanism behind "changing the charging current requires clicking the Charge button again" in known-issues.md.

[confirmed] reserveCurrent does not echo the requested current. It stayed 0 through every step, confirming it belongs to the scheduled-charging feature (§4.4) and is useless for verifying a setpoint.

[confirmed] The car draws less than the limit, by a margin that grows with the setpoint: 8 A → 7.17 A, 10 A → 8.88 A. So the current_tolerance = 1.0 in start_charging is too tight — at 10 A the deviation is 1.12 A and the retry loop would fire even though the setpoint was applied correctly. Verifying a setpoint against the measured current is unreliable in general; tracking the last setpoint actually sent is the sounder approach.

[confirmed] chargeStatus values seen live across the run: charging, finish, wait.

6. Electrical model

[confirmed] evsePhase is threephase and the reported per-connector voltage is ≈406 V — line-to-line on a 400 V system, not phase-to-neutral.

[confirmed] At full load, P = √3 × V_LL × I holds to 0.1 %, so current is a per-phase figure and voltage is line-to-line:

√3 × 394.41 V × 30.95 A = 21.141 kW      reported: 21.168 kW

This settles the old question of whether current was per-phase or a sum of phases: it is per-phase.

[confirmed] At partial load the relation breaks down, and not by a constant factor. Steady-state means over 25 samples per step:

I U P reported √3·U·I ratio
7.17 A 410.29 V 2.051 kW 5.094 kW 0.40
8.88 A 408.75 V 5.647 kW 6.287 kW 0.90
30.95 A 394.41 V 21.168 kW 21.141 kW 1.00

Current rises 24 % between the first two rows while power nearly triples. That step is the non-linearity reported in known-issues.md.

[untested] Which mechanism causes it is not resolved. Two candidates fit the shape but neither fits the numbers cleanly:

  1. Power factor — real power is √3 · U · I · cosφ, and an onboard charger's cosφ improves with load. But cosφ jumping 0.40 → 0.90 across a 24 % load change is abrupt for a PFC-equipped charger.
  2. Phase count — the car switching between single- and three-phase would give a genuine ~3× step. But a single-phase fit at 7.17 A predicts 1.70 kW against 2.05 kW measured, and a three-phase fit at 8.88 A predicts 6.29 kW against 5.65 kW measured.

The protocol only exposes one aggregate current per connector, so per-phase currents would be needed to separate these — a clamp meter on the individual phases would settle it in minutes.

[confirmed] Reported current and reported power can decouple almost entirely. A later run held a steady 6.63 A at 0.01 kW for 90 s — a substantial current at essentially zero real power, with the car presumably full or tapered out. No formula relating the two survives this, which settles the practical question even though the mechanism stays open.

Practical consequence: do not derive power from current. The reported power is real power and is trustworthy; √3 · U · I is apparent power and only coincides with it at full load. The supply also sags measurably under load (410 V idle → 394 V at 21 kW), so voltage is not a constant either.

[confirmed] meterInfo is always 0.00 because no CT clamp is installed. The fields are functional, not broken.

7. Open questions

Question How to settle it Blocks
Why is power non-linear in current — power factor or phase count? Clamp meter on the individual phases issue 4
Do fault and reserve really appear as chargeStatus? Watch for the warning _missing_ now logs issue 1
Why does the first Start after a session ignore the current? Unknown; the workaround (re-send) is proven issue 3

Settled by the 2026-08-13 measurements in §5a and §6: re-sending Start mid-session does change the current, reserveCurrent does not echo the request, and current is per-phase.

Live reference values captured 2026-08-13, charger idle: totalPower 57399 (573.99 kWh), chargeTimes 174, loadbalance 11700, rssi -67, per-connector voltage 402.98 / 403.64 V.

8. Dead ends — do not repeat

  • Public documentation. The S-Charge local protocol is undocumented. The only search hit anywhere is this repository.
  • jadx / apktool / openjdk on the APK. Flutter app; they decompile the shim only.
  • Port scanning for a config UI. Nothing is open; already scanned in full.
  • OCPP without vendor involvement. No configuration surface exists on this firmware.