Power Flow Input Data
The default input data is located in the data directory as the h5-file or xlsx-file, with variables bus, generator, branch, and basePower.
The minimum amount of information within an instance of the data structure required to run the module requires a bus branch.
First, the system base power is defined in (MVA) using basePower, and in the following, we describe the structure of other variables involved in the input file.
Bus data are located in data.system.bus with the structure:
| Column | Description | Unit |
|---|---|---|
| 1 | bus number | |
| 2 | bus type | |
| 3 | initial voltage magnitude | per-unit |
| 4 | initial voltage angle | degree |
| 5 | load real power injection | MW |
| 6 | load reactive power injection | MVAr |
| 7 | shunt element (equivalent active power) | MW |
| 8 | shunt element (equivalent reactive power) | MVAr |
| 9 | minimum voltage magnitude | per-unit |
| 10 | maximum voltage magnitude | per-unit |
Generator data are located in data.system.generator with the structure:
| Column | Description | Unit |
|---|---|---|
| 1 | bus number | |
| 2 | real power injection | MW |
| 3 | reactive power injection | MVAr |
| 4 | minimum reactive power injection | MVAr |
| 5 | maximum reactive power injection | MVAr |
| 6 | voltage magnitude | per-unit |
| 7 | on/off status |
Transmission line data are located in data.system.line with the structure:
| Column | Description | Unit |
|---|---|---|
| 1 | from bus number | |
| 2 | to bus number | |
| 3 | resistance | per-unit |
| 4 | reactance | per-unit |
| 5 | total charging susceptance | per-unit |
| 6 | on/off status |
In-phase transformer data are located in data.system.inTransformer with the structure:
| Column | Description | Unit |
|---|---|---|
| 1 | from bus number | |
| 2 | to bus number | |
| 3 | resistance | per-unit |
| 4 | reactance | per-unit |
| 5 | total charging susceptance | per-unit |
| 6 | turns ratio | |
| 7 | on/off status |
Phase-shifting transformer data are located in data.system.shiftTransformer with the structure:
| Column | Description | Unit |
|---|---|---|
| 1 | from bus number | |
| 2 | to bus number | |
| 3 | resistance | per-unit |
| 4 | reactance | per-unit |
| 5 | total charging susceptance | per-unit |
| 6 | turns ratio | |
| 7 | shift angle | degree |
| 8 | on/off status |
MATGRID is licensed under the terms of the MIT License.