Hello,

Finally took the time to install 1.0.6 with rotary encoder mod at 128Mhz.

I am really happy with the firmware so far. I also found some bugs I am reporting below:

  1. In 5us mode (10kHz test signal with 1V UP trigger), the selector switches between GND and DC constantly, clearing the selection and preventing to go somewhere else in the UI or to revert to another timescale
  2. 10Khz test signal is weird with timescale >1ms (2ms, 5ms, etc...) -> looks like <1khz signal
  3. 100Khz test signal is weird with timescale >100uS (200us, etc...) -> looks like <1khz signal
  4. Frequency calculation is really off. It is based on one period only ? 100Khz at 10uS varies +/- 25khz.
  5. Non working functions :
  • Button test = black screen
  • Test signal 3V = nothing happens
  1. The rotary switch actually requires to be rotated two steps to change a value (might be a hardware limitation?)

Apart from that, I attach a picture so you can use it in the README. For the firmware to be more widely used you have to polish a little bit the "commercial" side and the picture on the main page is not really appealing :)