Create a text file called InputFile.txt in the connector’s MAData folder, and then paste the following sample data into it:

EmployeeID;OfficePhone;MobilePhone;FaxPhone 100;425-555-0100;206-555-0101; 101;425-555-0120;206-555-0105;312-555-0151 102;425-555-0130;;312-555-0171 103;425-555-0125;; 104;425-555-0127;206-555-0115;312-555-0170 105;425-555-0119;;312-555-0101 11;425-555-0199;206-555-0175;312-555-0194

By default, the MAData folder can be found at:

%ProgramFiles%\Microsoft Forefront Identity Manager\2010\Synchronization Service\MAData\ 

Next, run the Full Import run profile for the connector. If successful, the results should look similar to the following screen capture.