Notifications
You must be signed in to change notification settings - Fork 11
Expand file tree
/
Copy pathvalues.go
More file actions
69 lines (59 loc) · 2.24 KB
/
values.go
File metadata and controls
69 lines (59 loc) · 2.24 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
/*
* This program is free software: you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation, either version 3 of the License, or
* (at your option) any later version.
*
* This program is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU General Public License for more details.
*
* You should have received a copy of the GNU General Public License
* along with this program. If not, see <https://www.gnu.org/licenses/>.
*/
package main
import (
"fmt"
"github.com/godbus/dbus/v5"
)
// InitializeValues sets up the initial D-Bus values.
func (a *App) InitializeValues() {
a.mu.Lock()
defer a.mu.Unlock()
set := func(path string, value, text interface{}) {
a.values[0][objectpath(path)] = dbus.MakeVariant(value)
a.values[1][objectpath(path)] = dbus.MakeVariant(text)
}
// Device identity
set("/Connected", 1, "1")
set("/CustomName", "Grid meter", "Grid meter")
set("/DeviceInstance", 30, "30")
set("/DeviceType", 71, "71")
set("/ErrorCode", 0, "0")
set("/FirmwareVersion", 2, "2")
set("/ProductName", "Grid meter", "Grid meter")
set("/ProductId", 45058, "45058")
set("/Role", "grid", "grid")
set("/Position", 0, "0")
// Process identity
set("/Mgmt/ProcessName", "shm-et340", "shm-et340")
set("/Mgmt/Connection", fmt.Sprintf("Multicast UDP %s", a.config.MulticastAddress), fmt.Sprintf("Multicast UDP %s", a.config.MulticastAddress))
set("/Mgmt/ProcessVersion", Version, Version)
// Serial — overwritten on first packet with real SMA serial
set("/Serial", "detecting...", "detecting...")
// Per-phase values initialized to zero
for _, phase := range []string{"/Ac/L1", "/Ac/L2", "/Ac/L3"} {
set(phase+"/Power", 0.0, "0.0 W")
set(phase+"/Voltage", 0.0, "0.00 V")
set(phase+"/Current", 0.0, "0.00 A")
set(phase+"/Energy/Forward", 0.0, "0.00 kWh")
set(phase+"/Energy/Reverse", 0.0, "0.00 kWh")
}
// Totals initialized to zero
set("/Ac/Power", 0.0, "0.0 W")
set("/Ac/Current", 0.0, "0.00 A")
set("/Ac/Voltage", 0.0, "0.00 V")
set("/Ac/Energy/Forward", 0.0, "0.00 kWh")
set("/Ac/Energy/Reverse", 0.0, "0.00 kWh")
}