[HCL] APC BX950MI supported by usbhid-ups #2741

@brankko

Description

@brankko

Product: https://www.se.com/de/de/product/BX950MI-GR/apc-backups-950-va-230-v-avr-4-schuko-ausg%C3%A4nge/

admin@truenas[~]$ upsc ups
Init SSL without certificate database
battery.charge: 100
battery.charge.low: 10
battery.mfr.date: 2001/01/01
battery.runtime: 1457
battery.runtime.low: 120
battery.type: PbAc
battery.voltage: 13.6
battery.voltage.nominal: 12.0
device.mfr: American Power Conversion
device.model: Back-UPS BX950MI 
device.serial: XXXXXXXXXXXX
device.type: ups
driver.name: usbhid-ups
driver.parameter.pollfreq: 30
driver.parameter.pollinterval: 2
driver.parameter.port: auto
driver.parameter.synchronous: auto
driver.version: 2.8.0
driver.version.data: APC HID 0.98
driver.version.internal: 0.47
driver.version.usb: libusb-1.0.26 (API: 0x1000109)
input.sensitivity: medium
input.transfer.high: 295
input.transfer.low: 145
input.voltage: 228.0
input.voltage.nominal: 230
ups.beeper.status: disabled
ups.delay.shutdown: 20
ups.firmware: 295202G -302202G 
ups.load: 19
ups.mfr: American Power Conversion
ups.mfr.date: 2022/05/30
ups.model: Back-UPS BX950MI 
ups.productid: 0002
ups.realpower.nominal: 520
ups.serial: XXXXXXXXXXXX
ups.status: OL
ups.test.result: Done and passed
ups.timer.reboot: 0
ups.timer.shutdown: -1
ups.vendorid: 051d
admin@truenas[~]$ upsrw ups
[battery.charge.low]
Remaining battery level when UPS switches to LB (percent)
Type: STRING
Maximum length: 10
Value: 10

[battery.mfr.date]
Battery manufacturing date
Type: STRING
Maximum length: 10
Value: 2001/01/01

[battery.runtime.low]
Remaining battery runtime when UPS switches to LB (seconds)
Type: STRING
Maximum length: 10
Value: 120

[input.sensitivity]
Input power sensitivity
Type: STRING
Maximum length: 10
Value: medium

[input.transfer.high]
High voltage transfer point (V)
Type: STRING
Maximum length: 10
Value: 295

[input.transfer.low]
Low voltage transfer point (V)
Type: STRING
Maximum length: 10
Value: 145

[ups.delay.shutdown]
Interval to wait after shutdown with delay command (seconds)
Type: STRING
Maximum length: 10
Value: 20
admin@truenas[~]$ upscmd -l ups
Instant commands supported on UPS [ups]:

beeper.disable - Disable the UPS beeper
beeper.enable - Enable the UPS beeper
beeper.mute - Temporarily mute the UPS beeper
beeper.off - Obsolete (use beeper.disable or beeper.mute)
beeper.on - Obsolete (use beeper.enable)
load.off - Turn off the load immediately
load.off.delay - Turn off the load with a delay (seconds)
shutdown.reboot - Shut down the load briefly while rebooting the UPS
shutdown.stop - Stop a shutdown in progress
test.battery.start.deep - Start a deep battery test
test.battery.start.quick - Start a quick battery test
test.battery.stop - Stop the battery test

So far everything works without any tweaks.