Configuration

rscp2mqtt offers the option for setting configuration parameters by a config file named .config.

Starting with release v3.38 configuration can also be set via environment variables. This simplifies the start of a Docker container, as no .config file is required.

If you use both, the environment variables overwrite the parameters set with .config! (Exception: parameters that can be set multiple times).

Configuration E3/DC and MQTT Broker

Key Value/Range Example
E3DC_IP string 192.168.178.11
E3DC_PORT 0 - 65535 5033
E3DC_USER string user@provider.de
E3DC_PASSWORD string mypwd
E3DC_AES_PASSWORD string myaespwd
MQTT_HOST string localhost
MQTT_PORT 0 - 65535 1883
MQTT_USER string
MQTT_PASSWORD string
MQTT_AUTH true/false false
MQTT_TLS_CAFILE string /home/pi/ca.crt
MQTT_TLS_CAPATH string
MQTT_TLS_CERTFILE string /home/pi/client.crt
MQTT_TLS_KEYFILE string /home/pi/client.key
MQTT_TLS_PASSWORD string
MQTT_TLS true/false false
MQTT_RETAIN true/false false
MQTT_QOS 0 - 2 0
PREFIX string e3dc

Configuration Output Values

Key Value/Range Example
AUTO_REFRESH true/false false
BATTERY_STRINGS integer 1
DAILY_VALUES true/false false
DCB_REQUESTS true/false true
EMS_REQUESTS true/false true
FORCE_PUB * string e3dc/[a-z]+/power
HISTORY_START_YEAR integer 2024
HST_REQUESTS true/false true
INTERVAL integer 4
LIMIT_CHARGE_SOC 0 - 100 0
LIMIT_DISCHARGE_SOC 0 - 100 0
LIMIT_CHARGE_DURABLE true/false false
LIMIT_DISCHARGE_DURABLE true/false false
LIMIT_DISCHARGE_BY_HOME_POWER 0 - 99999 0
PM_EXTERN true/false false
PM_INDEX integer 0
PM_REQUESTS true/false true
PVI_TRACKER integer 0
RAW_MODE true/false true
RAW_TOPIC_REGEX string
RETAIN_FOR_SETUP true/false true
SOC_LIMITER true/false false
STATISTIC_VALUES true/false true
USE_TRUE_FALSE true/false false
VERBOSE true/false false
WALLBOX true/false false
WB_INDEX integer 0

*) Multiple FORCE_PUB and INFLUXDB_TOPIC

The parameters FORCE_PUB and INFLUXDB_TOPIC can be set multiple times in the configuration file. This is not possible via environment variables, as the values would be overwritten. Therefore, please use FORCE_PUB_01, FORCE_PUB_02, INFLUXDB_TOPIC_01, INFLUXDB_TOPIC_02, INFLUXDB_TOPIC_03 etc.

InfluxDB

Key Value/Range Example
ENABLE_INFLUXDB true/false false
INFLUXDB_TOPIC * string e3dc/system/.*

Configuration for InfluxDB v1.x

Key Value/Range Example
INFLUXDB_HOST string localhost
INFLUXDB_PORT 0 - 65535 8086
INFLUXDB_VERSION integer 1
INFLUXDB_1_DB string e3dc
INFLUXDB_1_USER string
INFLUXDB_1_PASSWORD string
INFLUXDB_1_AUTH true/false false

Configuration for InfluxDB v2.x

Key Value/Range Example
INFLUXDB_2_ORGA string
INFLUXDB_2_BUCKET string
INFLUXDB_2_TOKEN string
INFLUXDB_MEASUREMENT string e3dc
INFLUXDB_MEASUREMENT_META string e3dc_meta

Configuration for InfluxDB SSL

Key Value/Range Example
CURL_HTTPS true/false false
CURL_OPT_SSL_VERIFYPEER true/false true
CURL_OPT_SSL_VERIFYHOST true/false true
CURL_OPT_CAINFO string
CURL_OPT_SSLCERT string
CURL_OPT_SSLKEY string

Hints

The prefix of the topics can be configured by the attribute PREFIX. By default all topics start with "e3dc". This can be changed to any other string that MQTT accepts as a topic, max. 24 characters. E.g. "s10" or "s10/1".

If your system has more than one battery string (e.g. S10 Pro), you have to configure the parameter BATTERY_STRINGS accordingly. Battery topics that belong to a battery string are extended by the number of the battery string. Battery modules (DCB topics) are numbered consecutively.

Logging can be configured for messages that the home power station output in response to a request. Messages are collected including a counter for the number of occurrences. The errors will be logged in a bundle at midnight, at the end of the program or by querying with e3dc/set/log/errors. This reduces the number of error messages. To do this, set in the .config file: LOG_MODE=BUFFERED. You can also switch off the logging of such messages completely with LOG_MODE=OFF. If every event is to be logged: LOG_MODE=ON.