Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy pathmain.go
More file actions
155 lines (136 loc) · 6.29 KB
/
Copy pathmain.go
File metadata and controls
155 lines (136 loc) · 6.29 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
package main
import (
"fmt"
"log"
"net/http"
"os"
"time"
"github.com/prometheus/client_golang/prometheus"
"github.com/prometheus/client_golang/prometheus/promhttp"
"github.com/simonvetter/modbus"
)
// DatakomCollector holds the modbus client and metric descriptors
type DatakomCollector struct {
client *modbus.ModbusClient
target string
// Metric descriptors
mainsV *prometheus.Desc
mainsI *prometheus.Desc
genPower *prometheus.Desc
genEnergy *prometheus.Desc
genFreq *prometheus.Desc
batteryV *prometheus.Desc
fuelLevel *prometheus.Desc
coolantTemp *prometheus.Desc
opStatus *prometheus.Desc
runHours *prometheus.Desc
serviceHours *prometheus.Desc
serviceDays *prometheus.Desc
}
// NewDatakomCollector initializes the collector with predefined metric descriptors
func NewDatakomCollector(client *modbus.ModbusClient, target string) *DatakomCollector {
return &DatakomCollector{
client: client,
target: target,
mainsV: prometheus.NewDesc("d500_mains_voltage_v", "Mains phase voltage", []string{"phase"}, nil),
mainsI: prometheus.NewDesc("d500_mains_current_a", "Mains phase current", []string{"phase"}, nil),
genPower: prometheus.NewDesc("d500_genset_power_kw", "Total Active Power", nil, nil),
genEnergy: prometheus.NewDesc("d500_total_energy_kwh", "Total Accumulated Energy", nil, nil),
genFreq: prometheus.NewDesc("d500_gen_freq_hz", "Genset Frequency", nil, nil),
batteryV: prometheus.NewDesc("d500_battery_v", "Battery Voltage", nil, nil),
fuelLevel: prometheus.NewDesc("d500_fuel_percent", "Fuel Level", nil, nil),
coolantTemp: prometheus.NewDesc("d500_engine_temp_c", "Coolant Temperature", nil, nil),
opStatus: prometheus.NewDesc("d500_op_status", "Operational Status", nil, nil),
runHours: prometheus.NewDesc("d500_run_hours_total", "Total Engine Run Hours", nil, nil),
serviceHours: prometheus.NewDesc("d500_service_hours_remain", "Hours remaining to Maintenance", nil, nil),
serviceDays: prometheus.NewDesc("d500_service_days_remain", "Days remaining to Maintenance", nil, nil),
}
}
// Describe sends the descriptors of each metric over to Prometheus
func (c *DatakomCollector) Describe(ch chan<- *prometheus.Desc) {
ch <- c.mainsV
ch <- c.mainsI
ch <- c.genPower
ch <- c.genEnergy
ch <- c.genFreq
ch <- c.batteryV
ch <- c.fuelLevel
ch <- c.coolantTemp
ch <- c.opStatus
ch <- c.runHours
ch <- c.serviceHours
ch <- c.serviceDays
}
// Collect triggers the Modbus polling logic during every scrape request
func (c *DatakomCollector) Collect(ch chan<- prometheus.Metric) {
log.Printf("Starting scrape for target %s", c.target)
// Open connection to the controller
if err := c.client.Open(); err != nil {
log.Printf("Failed to connect to %s: %v", c.target, err)
return
}
defer c.client.Close()
// Block 1: Mains Voltages (Addr: 10240)
if r, err := c.client.ReadRegisters(10240, 6, modbus.HOLDING_REGISTER); err == nil {
ch <- prometheus.MustNewConstMetric(c.mainsV, prometheus.GaugeValue, float64(getUint32(r, 0))/10.0, "L1")
ch <- prometheus.MustNewConstMetric(c.mainsV, prometheus.GaugeValue, float64(getUint32(r, 2))/10.0, "L2")
ch <- prometheus.MustNewConstMetric(c.mainsV, prometheus.GaugeValue, float64(getUint32(r, 4))/10.0, "L3")
}
// Block 2: Mains Currents (Addr: 10264)
if r, err := c.client.ReadRegisters(10264, 6, modbus.HOLDING_REGISTER); err == nil {
ch <- prometheus.MustNewConstMetric(c.mainsI, prometheus.GaugeValue, float64(getUint32(r, 0))/10.0, "I1")
ch <- prometheus.MustNewConstMetric(c.mainsI, prometheus.GaugeValue, float64(getUint32(r, 2))/10.0, "I2")
ch <- prometheus.MustNewConstMetric(c.mainsI, prometheus.GaugeValue, float64(getUint32(r, 4))/10.0, "I3")
}
// Block 3: Engine Parameters and Frequency (Addr: 10294-10363)
if r, err := c.client.ReadRegisters(10294, 2, modbus.HOLDING_REGISTER); err == nil {
ch <- prometheus.MustNewConstMetric(c.genPower, prometheus.GaugeValue, float64(getUint32(r, 0))/10.0)
}
if r, err := c.client.ReadRegisters(10339, 25, modbus.HOLDING_REGISTER); err == nil && len(r) >= 25 {
ch <- prometheus.MustNewConstMetric(c.genFreq, prometheus.GaugeValue, float64(r[0])/100.0)
ch <- prometheus.MustNewConstMetric(c.batteryV, prometheus.GaugeValue, float64(r[2])/100.0)
ch <- prometheus.MustNewConstMetric(c.coolantTemp, prometheus.GaugeValue, float64(r[23])/10.0)
ch <- prometheus.MustNewConstMetric(c.fuelLevel, prometheus.GaugeValue, float64(r[24])/10.0)
}
// Block 4: Operation Status and Service Counters (Addr: 10604-10636)
if r, err := c.client.ReadRegisters(10604, 34, modbus.HOLDING_REGISTER); err == nil && len(r) >= 34 {
ch <- prometheus.MustNewConstMetric(c.opStatus, prometheus.GaugeValue, float64(r[0]))
ch <- prometheus.MustNewConstMetric(c.runHours, prometheus.GaugeValue, float64(getUint32(r, 18))/100.0)
ch <- prometheus.MustNewConstMetric(c.genEnergy, prometheus.GaugeValue, float64(getUint32(r, 24))/10.0)
ch <- prometheus.MustNewConstMetric(c.serviceHours, prometheus.GaugeValue, float64(getUint32(r, 30))/100.0)
ch <- prometheus.MustNewConstMetric(c.serviceDays, prometheus.GaugeValue, float64(getUint32(r, 32))/100.0)
}
}
// getUint32 handles word swapping for 32-bit values: Low Word First (Little-Endian Word Order)
func getUint32(regs []uint16, offset int) uint32 {
if len(regs) < offset+2 {
return 0
}
// Datakom D500 uses Low Word first
return uint32(regs[offset+1])<<16 | uint32(regs[offset])
}
func getEnv(key, fallback string) string {
if value, ok := os.LookupEnv(key); ok {
return value
}
return fallback
}
func main() {
// Connection settings derived from environment variables
host := getEnv("DATAKOM_HOST", "192.168.100.100")
port := getEnv("DATAKOM_PORT", "502")
address := fmt.Sprintf("tcp://%s:%s", host, port)
// Initialize Modbus TCP client
client, _ := modbus.NewClient(&modbus.ClientConfiguration{
URL: address, Timeout: 5 * time.Second,
})
client.SetUnitId(1) // Standard Modbus Address for Datakom devices
// Register the custom real-time collector
collector := NewDatakomCollector(client, address)
prometheus.MustRegister(collector)
// Start the HTTP server for Prometheus scraping
exporterPort := getEnv("EXPORTER_PORT", "8000")
log.Printf("Prometheus Exporter started on :%s/metrics (Target: %s)", exporterPort, address)
http.Handle("/metrics", promhttp.Handler())
log.Fatal(http.ListenAndServe(":"+exporterPort, nil))
}