0x501B TimelapseInterval

Sets and Returns the current value of the interval (msec) of shots in interval shooting mode.

Supported Models

X Z1 V SC S
Field Order Field Name Size Data Type Description
1 Property Code 2 UINT16 0x501B
2 Datatype 2 UINT16 0x0006 (UINT32)
3 Get/Set 1 UINT8 0x01 (GET/SET)
4 Default Value 4 UINT32 Refer to Supported Value
5 Current Value 4 UINT32
6 Form Flag 1 UINT8 0x01 (Range)
7 Minimum Value 4 UINT32 Refer to Supported Value
8 Maximum Value 4 UINT32 Refer to Supported Value
9 Step Size 4 UINT32 1000 (1000 msec)

Warning

For THETA S/SC, this property is available only when 0x5013 StillCaptureMode is 0x0001 Single-shot shooting. Configure this property prior to changing 0x5013 StillCaptureMode to 0x0003 Interval shooting.

Supported Values

THETA X

Field Name Description
Default Value 6000 (6 sec)
Minimum Value 6000 (6 sec)
Maximum Value 3600000 (3600 sec)

THETA Z1

0xD827 ImageFormat Field Name Description
0x00 (JPEG) Default Value 6000 (6 sec)
Minimum Value 6000 (6 sec)
Maximum Value 3600000 (3600 sec)
0x01 (RAW+) Default Value 10000 (10 sec)
Minimum Value 10000 (10 sec)
Maximum Value 3600000 (3600 sec)

THETA V

Field Name Description
Default Value 4000 (4 sec)
Minimum Value 6000 (6 sec)
Maximum Value 3600000 (3600 sec)

THETA SC/S

0x5003 ImageSize Field Name Description
5376x2688\0 Default Value 8000 (8 sec)
Minimum Value 8000 (8 sec)
Maximum Value 3600000 (3600 sec)
2048x1024\0 Default Value 5000 (5 sec)
Minimum Value 5000 (5 sec)
Maximum Value 3600000 (3600 sec)