@@ -8064,7 +8064,7 @@ save_PD_MEAS_OVERALL
80648064 _definition.id PD_MEAS_OVERALL
80658065 _definition.scope Category
80668066 _definition.class Set
8067- _definition.update 2025-04-18
8067+ _definition.update 2025-06-19
80688068 _description.text
80698069;
80708070 This section contains information about the conditions used for
@@ -8078,6 +8078,90 @@ save_PD_MEAS_OVERALL
80788078 _name.object_id PD_MEAS_OVERALL
80798079 _category_key.name '_pd_meas_overall.diffractogram_id'
80808080
8081+ loop_
8082+ _description_example.case
8083+ _description_example.detail
8084+ ;
8085+ _pd_diffractogram.id PATTERN_37
8086+
8087+ _pd_meas.2theta_range_min 5.00
8088+ _pd_meas.2theta_range_max 95.00
8089+ _pd_meas.2theta_range_inc 0.02
8090+ _pd_meas.number_of_points 4501
8091+ _pd_meas.scan_method cont
8092+
8093+ _pd_meas.datetime_initiated 2023-02-27T22:45:00+08:00
8094+
8095+ _pd_meas.rocking_angle 180
8096+ _pd_meas.rocking_axis phi
8097+ _pd_instr.geometry Bragg-Brentano
8098+
8099+ loop_
8100+ _pd_data.point_id
8101+ _pd_meas.counts_total
8102+ 1 1234
8103+ 2 1256
8104+ #...
8105+ ;
8106+ ;
8107+ The measured diffractogram is in equally spaced 2θ points, starting
8108+ at 5.00° 2θ, going up in steps of 0.02°, with the last data point at
8109+ 95.00° 2θ. In total, there are 4501 data points. The data were
8110+ collected in a continuous scan, such that the detector did not stop
8111+ moving, and the intensities were binned according to the goniometer
8112+ angle during the collection time per step. Data collection was started
8113+ on the 27^th^ of February, 2023 at 2245 h in a timezone +8 h from UTC.
8114+ The specimen was rotated 180° during the collection of the data for
8115+ each measurement point.
8116+ ;
8117+ ;
8118+ _pd_meas.rocking_angle 2.5
8119+ _pd_meas.rocking_axis omega
8120+ _pd_meas.scan_method step
8121+
8122+ _pd_instr.geometry Bragg-Brentano
8123+
8124+ _pd_diffractogram.id PATTERN_96
8125+
8126+ loop_
8127+ _pd_data.point_id
8128+ _pd_meas.2theta_scan
8129+ _pd_meas.counts_total
8130+ 1 5.02 1234
8131+ 2 5.04 1256
8132+ #...
8133+ ;
8134+ ;
8135+ The information here applies to the diffractogram with the id
8136+ 'PATTERN_96'. For each measurement point, the specimen rotated ±2.5°
8137+ from its standard position about the omega axis.
8138+ ;
8139+ ;
8140+ _pd_diffractogram.id EDD_123
8141+
8142+ _pd_meas.2theta_fixed 5
8143+ _pd_meas.angle_chi 45
8144+ _pd_meas.units_of_intensity
8145+ 'Proportional to current (ampere) from Si(Li) detector.'
8146+ _pd_meas.scan_method disp
8147+
8148+ loop_
8149+ _pd_data.point_id
8150+ _pd_proc.energy_detection
8151+ _pd_meas.intensity_total
8152+ _pd_meas.intensity_total_su
8153+ 1 50300 1234 23
8154+ 2 50400 1256 24
8155+ #...
8156+ ;
8157+ ;
8158+ The information here applies to the diffractogram with the id
8159+ 'EDD_123'. The detector was fixed at 5° 2θ and tilted at
8160+ 45° χ. The data were collected in energy-dispersive mode, where
8161+ the intensity recorded was proportional to the current measured in
8162+ the Si(Li) detector.
8163+ ;
8164+
80818165save_
80828166
80838167save_pd_meas.2theta_fixed
@@ -13300,8 +13384,8 @@ save_
1330013384 disparate loop; they cannot be assigned values independently.
1330113385
1330213386 Added examples to PD_CALC_OVERALL, PD_CALIB_INCIDENT_INTENSITY, PD_CHAR,
13303- PD_DIFFRACTOGRAM, PD_PEAK, _pd_phase.id, PD_PHASE_MASSS, PD_PREP ,
13304- PD_PROC_LS, PD_QPA_CALIB_FACTOR, PD_SPEC.
13387+ PD_DIFFRACTOGRAM, PD_MEAS_OVERALL, PD_PEAK, _pd_phase.id, PD_PHASE_MASSS,
13388+ PD_PREP, PD_PROC_LS, PD_QPA_CALIB_FACTOR, PD_SPEC.
1330513389
1330613390 Add _pd_peak.overall_id
1330713391
0 commit comments