@@ -7923,7 +7923,7 @@ save_PD_INSTR_DETECTOR
79237923 _definition.id PD_INSTR_DETECTOR
79247924 _definition.scope Category
79257925 _definition.class Loop
7926- _definition.update 2023-01-06
7926+ _definition.update 2025-06-19
79277927 _description.text
79287928;
79297929 This category contains information relevant to the detector
@@ -7950,6 +7950,79 @@ save_PD_INSTR_DETECTOR
79507950 _name.object_id PD_INSTR_DETECTOR
79517951 _category_key.name '_pd_instr_detector.id'
79527952
7953+ loop_
7954+ _description_example.case
7955+ _description_example.detail
7956+ ;
7957+ loop_
7958+ _pd_instr_detector.id
7959+ _pd_instr.dist_spec_detc
7960+ _pd_instr.slit_ax_spec_detc
7961+ _pd_instr.slit_eq_spec_detc
7962+ _pd_instr_detector.instr_id
7963+ fd343493 320 8.5 0.075 b4131be5
7964+ 47540661 320 8.5 0.075 b4131be5
7965+ ;
7966+ ;
7967+ These detectors are paired with the instrument identified by the
7968+ id b4131be5.
7969+
7970+ There are two detectors, fd343493 and 47540661. Both detectors are
7971+ positioned 320 mm from the specimen, and are defined by two slits,
7972+ 8.5 mm in the axial direction, and 0.075 mm in the equatorial direction.
7973+ As the detector window is 8.5 mm wide, with 75 μm wide pixels, this is
7974+ represented by _pd_instr.slit_eq_spec_detc as 0.075 and
7975+ _pd_instr.slit_ax_spec_detc as 8.5
7976+ ;
7977+ ;
7978+ _pd_instr_detector.id WhizzBang
7979+ _pd_instr_detector.instr_id 58b6d83b
7980+ _pd_instr.2theta_monochr_post 31.0
7981+ _pd_instr.dist_anal_detc 47
7982+ _pd_instr.dist_spec_anal 135
7983+ _pd_instr.monochr_post_spec 'Graphite mosaic monochromator'
7984+ _pd_instr.slit_ax_spec_anal 9.5
7985+ _pd_instr.slit_eq_spec_anal 0.5
7986+ _pd_instr.soller_eq_spec_anal 2.5
7987+ _pd_instr.special_details
7988+ ;
7989+ The equatorial slit between the specimen and monochromator
7990+ lies on the detector circle.
7991+ ;
7992+ ;
7993+ ;
7994+ The 'WhizzBang' detector is paired with the instrument identified by the
7995+ id 58b6d83b.
7996+
7997+ The post-specimen, graphite, mosaic monochromator is set at 31.0° 2θ.
7998+ The monochromator is situated 47 mm from the detector. The distance from
7999+ the specimen to the monochromator is 135 mm. The width of the beam is
8000+ defined at the monochromator by a 9.5 mm mask. There is a 0.5 mm
8001+ equatorial slit on the detector circle between the specimen and
8002+ monochromator, which acts as the virtual detector. There are 2.5° axial
8003+ Soller slits between the specimen and the monochromator.
8004+ ;
8005+ ;
8006+ _pd_instr_detector.instr_id 58b6d83b
8007+ _pd_instr_detector.id A
8008+ _pd_instr.dist_spec_detc 117.5
8009+ _pd_instr.monochr_post_spec 'Fe filter'
8010+ _pd_instr.slit_ax_spec_detc 12
8011+ _pd_instr.slit_eq_spec_detc 0.075
8012+ _pd_instr.soller_ax_spec_detc 2.5
8013+ ;
8014+ ;
8015+ The 'A' detector is paired with the instrument identified by the
8016+ id 58b6d83b.
8017+
8018+ The distance from the specimen to the detector is 117.5 mm. The X-ray
8019+ beam is "monochromatised" by a metal Fe filter. The detector is defined
8020+ by a 12 mm axial and 0.075 mm equatorial slit. The small size of the
8021+ equatorial slit might lead the reader to assume a strip detector was
8022+ used. This should be documented using _pd_instr.special_details. There
8023+ are 2.5° axial Soller slits between the specimen and the detector.
8024+ ;
8025+
79538026save_
79548027
79558028save_pd_instr.2theta_monochr_post
@@ -14353,9 +14426,11 @@ save_
1435314426 clarify that identical values refer to the same data point in each
1435414427 disparate loop; they cannot be assigned values independently.
1435514428
14429+ Added _pd_instr_detector.instr_id
14430+
1435614431 Added examples to PD_CALC_OVERALL, PD_CALIB_INCIDENT_INTENSITY, PD_CHAR,
14357- PD_DIFFRACTOGRAM, PD_INSTR, PD_MEAS_OVERALL, PD_PEAK, _pd_phase.id ,
14358- PD_PHASE_MASSS , PD_PREP, PD_PROC_LS, PD_PROC_OVERALL,
14432+ PD_DIFFRACTOGRAM, PD_INSTR, PD_INSTR_DETECTOR, PD_MEAS_OVERALL, PD_PEAK ,
14433+ _pd_phase.id, PD_PHASE_MASS , PD_PREP, PD_PROC_LS, PD_PROC_OVERALL,
1435914434 PD_QPA_CALIB_FACTOR, PD_QPA_INTENSITY_FACTOR, PD_QPA_INTERNAL_STD,
1436014435 PD_SPEC.
1436114436
0 commit comments