@@ -9045,50 +9045,55 @@ save_PD_PHASE_MASS
90459045 _description_example.detail
90469046;
90479047 _audit.schema Custom
9048+ _pd_diffractogram.id A_DIFFRACTOGRAM
90489049
90499050 loop_
9050- _pd_phase_mass.diffractogram_id
90519051 _pd_phase_mass.phase_id
90529052 _pd_phase_mass.percent
90539053 _pd_phase_mass.percent_su
9054- A_DIFFRACTOGRAM PHASE_1 45.45 0.42
9055- A_DIFFRACTOGRAM PHASE_2 37.42 0.63
9056- A_DIFFRACTOGRAM PHASE_3 17.13 0.53
9054+ PHASE_1 45.45 0.42
9055+ PHASE_2 37.42 0.63
9056+ PHASE_3 17.13 0.53
90579057;
90589058;
9059- Tabulation of quantitative phase analysis data. The phase masses,
9060- expressed as percentages of the entire specimen are given, along with
9061- their associated standard uncertainties. The values are associated with
9062- one diffractogram and three phases.
9059+ Tabulation of quantitative phase analysis data. The relative phase
9060+ masses, expressed as percentages of the entire specimen, are given
9061+ along with their associated standard uncertainties. The values are
9062+ associated with one diffractogram and three phases.
90639063
9064- Blocks containing information about more than one phase must set a
9065- non-default value for _audit.schema.
9064+ Blocks containing information about more than one phase or
9065+ diffractogram must set a non-default value for _audit.schema.
90669066;
90679067
90689068;
9069- _audit.schema Custom
9069+ _audit.schema Custom
9070+
9071+ _pd_diffractogram.id ANOTHER_DIFFRACTOGRAM
9072+
9073+ _pd_qpa_internal_std.mass_percent 25.000
9074+ _pd_qpa_internal_std.phase_id PHASE_2
90709075
90719076 loop_
90729077 _pd_phase_mass.phase_id
90739078 _pd_phase_mass.percent
9074- _pd_phase_mass.percent_su
9075- PHASE_1 45.45 0.42
9076- PHASE_2 37.42 0.63
9077- PHASE_3 17.13 0.53
9079+ _pd_phase_mass.absolute
9080+ _pd_phase_mass.original
9081+ PHASE_1 45.45 30.36 40.49
9082+ PHASE_2 37.42 25.00 0
9083+ PHASE_3 17.13 11.44 15.26
90789084;
90799085;
9080- Tabulation of quantitative phase analysis data. The phase masses,
9081- expressed as percentages of the entire specimen are given, along with
9082- their associated standard uncertainties. The values are associated with
9083- three phases.
9086+ Tabulation of quantitative phase analysis data.
90849087
9085- The method of presentation given here would be associated with being
9086- present in a block which already contains a _pd_diffractogram.id
9087- data item; the value of _pd_phase_mass.diffractogram_id is linked to
9088- that value.
9088+ The relative phase masses are given by _pd_phase_mass.percent, and as
9089+ we know that PHASE_2 is an internal standard, we can also
9090+ calculate the absolute mass percentages in the specimen, given by
9091+ _pd_phase_mass.absolute. We can then calculate the original mass
9092+ percentages, those present in the sample before adding the internal
9093+ standard, given by _pd_phase_mass.original.
90899094
9090- When information about more than one phase is contained in a single
9091- data block, _audit.schema should have a non-default value.
9095+ Blocks containing information about more than one phase or
9096+ diffractogram must set a non-default value for _audit.schema .
90929097;
90939098
90949099save_
@@ -12939,5 +12944,5 @@ save_
1293912944 disparate loop; they cannot be assigned values independently.
1294012945
1294112946 Added examples to PD_CALC_OVERALL, PD_CALIB_INCIDENT_INTENSITY, PD_CHAR,
12942- _pd_diffractogram.id.
12947+ _pd_diffractogram.id, PD_PHASE_MASS .
1294312948;
0 commit comments