Skip to content

Commit 10f22a9

Browse files
Update tests for addition of first law efficiency output
1 parent 4ab2cb7 commit 10f22a9

24 files changed

+117
-93
lines changed

tests/example1_addons.csv

Lines changed: 2 additions & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -97,8 +97,9 @@ SURFACE EQUIPMENT SIMULATION RESULTS,Initial Net Electricity Generation,,5.22,MW
9797
SURFACE EQUIPMENT SIMULATION RESULTS,Average Annual Total Electricity Generation,,43.85,GWh
9898
SURFACE EQUIPMENT SIMULATION RESULTS,Average Annual Net Electricity Generation,,42.3,GWh
9999
SURFACE EQUIPMENT SIMULATION RESULTS,Average Pumping Power,,0.2,MW
100+
SURFACE EQUIPMENT SIMULATION RESULTS,First Law Efficiency,,10.07,%
100101
SURFACE EQUIPMENT SIMULATION RESULTS,Initial pumping power/net installed power,,3.82,%
101-
Simulation Metadata,GEOPHIRES Version,,3.6.3,
102+
Simulation Metadata,GEOPHIRES Version,,3.6.9,
102103
POWER GENERATION PROFILE,THERMAL DRAWDOWN,1,1.0,
103104
POWER GENERATION PROFILE,THERMAL DRAWDOWN,2,1.0056,
104105
POWER GENERATION PROFILE,THERMAL DRAWDOWN,3,1.0073,

tests/examples/Fervo_Norbeck_Latimer_2023.out

Lines changed: 5 additions & 4 deletions
Original file line numberDiff line numberDiff line change
@@ -4,10 +4,10 @@
44

55
Simulation Metadata
66
----------------------
7-
GEOPHIRES Version: 3.6.7
8-
Simulation Date: 2025-01-14
9-
Simulation Time: 07:37
10-
Calculation Time: 0.438 sec
7+
GEOPHIRES Version: 3.6.9
8+
Simulation Date: 2025-01-17
9+
Simulation Time: 11:25
10+
Calculation Time: 0.461 sec
1111

1212
***SUMMARY OF RESULTS***
1313

@@ -129,6 +129,7 @@ Simulation Metadata
129129
Average Annual Net Electricity Generation: 17.70 GWh
130130
Initial pumping power/net installed power: 28.16 %
131131
Average Pumping Power: 0.63 MW
132+
First Law Efficiency: 9.95 %
132133

133134
************************************************************
134135
* HEATING, COOLING AND/OR ELECTRICITY PRODUCTION PROFILE *

tests/examples/Fervo_Project_Cape-2.out

Lines changed: 5 additions & 4 deletions
Original file line numberDiff line numberDiff line change
@@ -4,10 +4,10 @@
44

55
Simulation Metadata
66
----------------------
7-
GEOPHIRES Version: 3.6.3
8-
Simulation Date: 2024-11-18
9-
Simulation Time: 16:56
10-
Calculation Time: 2.730 sec
7+
GEOPHIRES Version: 3.6.9
8+
Simulation Date: 2025-01-17
9+
Simulation Time: 11:25
10+
Calculation Time: 0.690 sec
1111

1212
***SUMMARY OF RESULTS***
1313

@@ -127,6 +127,7 @@ Simulation Metadata
127127
Average Annual Net Electricity Generation: 69.67 GWh
128128
Initial pumping power/net installed power: 1.68 %
129129
Average Pumping Power: 0.15 MW
130+
First Law Efficiency: 16.00 %
130131

131132
************************************************************
132133
* HEATING, COOLING AND/OR ELECTRICITY PRODUCTION PROFILE *

tests/examples/Fervo_Project_Cape-3.out

Lines changed: 5 additions & 4 deletions
Original file line numberDiff line numberDiff line change
@@ -4,10 +4,10 @@
44

55
Simulation Metadata
66
----------------------
7-
GEOPHIRES Version: 3.6.4
8-
Simulation Date: 2024-11-18
9-
Simulation Time: 19:49
10-
Calculation Time: 3.484 sec
7+
GEOPHIRES Version: 3.6.9
8+
Simulation Date: 2025-01-17
9+
Simulation Time: 11:25
10+
Calculation Time: 0.919 sec
1111

1212
***SUMMARY OF RESULTS***
1313

@@ -128,6 +128,7 @@ Simulation Metadata
128128
Average Annual Net Electricity Generation: 3171.75 GWh
129129
Initial pumping power/net installed power: 13.50 %
130130
Average Pumping Power: 53.73 MW
131+
First Law Efficiency: 14.39 %
131132

132133
************************************************************
133134
* HEATING, COOLING AND/OR ELECTRICITY PRODUCTION PROFILE *

tests/examples/Fervo_Project_Cape.out

Lines changed: 5 additions & 4 deletions
Original file line numberDiff line numberDiff line change
@@ -4,10 +4,10 @@
44

55
Simulation Metadata
66
----------------------
7-
GEOPHIRES Version: 3.6.3
8-
Simulation Date: 2024-11-18
9-
Simulation Time: 16:54
10-
Calculation Time: 3.061 sec
7+
GEOPHIRES Version: 3.6.9
8+
Simulation Date: 2025-01-17
9+
Simulation Time: 11:25
10+
Calculation Time: 0.689 sec
1111

1212
***SUMMARY OF RESULTS***
1313

@@ -127,6 +127,7 @@ Simulation Metadata
127127
Average Annual Net Electricity Generation: 693.77 GWh
128128
Initial pumping power/net installed power: 19.31 %
129129
Average Pumping Power: 17.82 MW
130+
First Law Efficiency: 13.05 %
130131

131132
************************************************************
132133
* HEATING, COOLING AND/OR ELECTRICITY PRODUCTION PROFILE *

tests/examples/S-DAC-GT.out

Lines changed: 5 additions & 4 deletions
Original file line numberDiff line numberDiff line change
@@ -4,10 +4,10 @@
44

55
Simulation Metadata
66
----------------------
7-
GEOPHIRES Version: 3.6.3
8-
Simulation Date: 2024-11-11
9-
Simulation Time: 15:20
10-
Calculation Time: 0.406 sec
7+
GEOPHIRES Version: 3.6.9
8+
Simulation Date: 2025-01-17
9+
Simulation Time: 11:25
10+
Calculation Time: 0.106 sec
1111

1212
***SUMMARY OF RESULTS***
1313

@@ -128,6 +128,7 @@ Simulation Metadata
128128
Initial Net Heat Production: 14.05 MW
129129
Average Annual Heat Production: -4.73 GWh
130130
Average Pumping Power: 0.19 MW
131+
First Law Efficiency: 16.55 %
131132

132133
************************************************************
133134
* HEATING, COOLING AND/OR ELECTRICITY PRODUCTION PROFILE *

tests/examples/Wanju_Yuan_Closed-Loop_Geothermal_Energy_Recovery.out

Lines changed: 5 additions & 4 deletions
Original file line numberDiff line numberDiff line change
@@ -4,10 +4,10 @@
44

55
Simulation Metadata
66
----------------------
7-
GEOPHIRES Version: 3.6.7
8-
Simulation Date: 2025-01-14
9-
Simulation Time: 07:37
10-
Calculation Time: 1.613 sec
7+
GEOPHIRES Version: 3.6.9
8+
Simulation Date: 2025-01-17
9+
Simulation Time: 11:25
10+
Calculation Time: 1.655 sec
1111

1212
***SUMMARY OF RESULTS***
1313

@@ -109,6 +109,7 @@ The AGS models contain an intrinsic reservoir model that doesn't expose values t
109109
Average Annual Net Electricity Generation: 8.63 GWh
110110
Initial pumping power/net installed power: 0.13 %
111111
Average Pumping Power: 0.00 MW
112+
First Law Efficiency: 5.16 %
112113

113114
************************************************************
114115
* HEATING, COOLING AND/OR ELECTRICITY PRODUCTION PROFILE *

tests/examples/example1.out

Lines changed: 5 additions & 4 deletions
Original file line numberDiff line numberDiff line change
@@ -4,10 +4,10 @@
44

55
Simulation Metadata
66
----------------------
7-
GEOPHIRES Version: 3.6.3
8-
Simulation Date: 2024-11-11
9-
Simulation Time: 14:48
10-
Calculation Time: 3.450 sec
7+
GEOPHIRES Version: 3.6.9
8+
Simulation Date: 2025-01-17
9+
Simulation Time: 11:23
10+
Calculation Time: 0.923 sec
1111

1212
***SUMMARY OF RESULTS***
1313

@@ -126,6 +126,7 @@ Simulation Metadata
126126
Average Annual Net Electricity Generation: 42.28 GWh
127127
Initial pumping power/net installed power: 3.82 %
128128
Average Pumping Power: 0.20 MW
129+
First Law Efficiency: 10.07 %
129130

130131
************************************************************
131132
* HEATING, COOLING AND/OR ELECTRICITY PRODUCTION PROFILE *

tests/examples/example13.out

Lines changed: 5 additions & 4 deletions
Original file line numberDiff line numberDiff line change
@@ -4,10 +4,10 @@
44

55
Simulation Metadata
66
----------------------
7-
GEOPHIRES Version: 3.6.3
8-
Simulation Date: 2024-11-11
9-
Simulation Time: 15:07
10-
Calculation Time: 0.143 sec
7+
GEOPHIRES Version: 3.6.9
8+
Simulation Date: 2025-01-17
9+
Simulation Time: 11:23
10+
Calculation Time: 0.037 sec
1111

1212
***SUMMARY OF RESULTS***
1313

@@ -132,6 +132,7 @@ Simulation Metadata
132132
Initial Net Heat Production: 19.63 MW
133133
Average Annual Heat Production: 108.31 GWh
134134
Average Pumping Power: 0.25 MW
135+
First Law Efficiency: 7.58 %
135136

136137
************************************************************
137138
* HEATING, COOLING AND/OR ELECTRICITY PRODUCTION PROFILE *

tests/examples/example1_addons.out

Lines changed: 5 additions & 4 deletions
Original file line numberDiff line numberDiff line change
@@ -4,10 +4,10 @@
44

55
Simulation Metadata
66
----------------------
7-
GEOPHIRES Version: 3.6.3
8-
Simulation Date: 2024-11-11
9-
Simulation Time: 15:09
10-
Calculation Time: 3.281 sec
7+
GEOPHIRES Version: 3.6.9
8+
Simulation Date: 2025-01-17
9+
Simulation Time: 11:23
10+
Calculation Time: 0.817 sec
1111

1212
***SUMMARY OF RESULTS***
1313

@@ -127,6 +127,7 @@ Simulation Metadata
127127
Average Annual Net Electricity Generation: 42.30 GWh
128128
Initial pumping power/net installed power: 3.82 %
129129
Average Pumping Power: 0.20 MW
130+
First Law Efficiency: 10.07 %
130131

131132
************************************************************
132133
* HEATING, COOLING AND/OR ELECTRICITY PRODUCTION PROFILE *

0 commit comments