@@ -17,43 +17,43 @@ Gradient 1,28, ---[deg.C/km]
17
17
Maximum Temperature,400, ---[deg.C]
18
18
Number of Production Wells,1, ---[-]
19
19
Number of Injection Wells,1, ---[-]
20
- Production Well Diameter,7, ---[inch]
21
- Injection Well Diameter,7, ---[inch]
20
+ Production Well Diameter,7, ---[inch]
21
+ Injection Well Diameter,7, ---[inch]
22
22
Ramey Production Wellbore Model,1, ---0 if disabled 1 if enabled
23
23
Injection Wellbore Temperature Gain,0, ---[deg.C]
24
24
Production Flow Rate per Well,40, ---[kg/s]
25
25
Fracture Shape,3, ---[-] Should be 1 2 3 or 4. See manual for details
26
- Fracture Height,700, ---[m]
26
+ Fracture Height,700, ---[m]
27
27
Reservoir Volume Option,1, ---[-] Should be 1 2 3 or 4. See manual for details
28
- Number of Fractures,5, ---[-]
29
- Fracture Separation,100, ---[m]
30
- Reservoir Impedance,0.05, ---[GPa*s/m3]
31
- Water Loss Fraction,.02, ---[-]
32
- Productivity Index,5, ---[kg/s/bar]
33
- Injectivity Index,5, ---[kg/s/bar]
34
- Injection Temperature,60, ---[deg.C]
35
- Maximum Drawdown,1, ---[-] no redrilling considered
36
- Reservoir Heat Capacity,825, ---[J/kg/K]
37
- Reservoir Density,2730, ---[kg/m^3]
28
+ Number of Fractures,5, ---[-]
29
+ Fracture Separation,100, ---[m]
30
+ Reservoir Impedance,0.05, ---[GPa*s/m3]
31
+ Water Loss Fraction,.02, ---[-]
32
+ Productivity Index,5, ---[kg/s/bar]
33
+ Injectivity Index,5, ---[kg/s/bar]
34
+ Injection Temperature,60, ---[deg.C]
35
+ Maximum Drawdown,1, ---[-] no redrilling considered
36
+ Reservoir Heat Capacity,825, ---[J/kg/K]
37
+ Reservoir Density,2730, ---[kg/m^3]
38
38
Reservoir Thermal Conductivity,2.83, ---[W/m/K]
39
39
40
40
***SURFACE TECHNICAL PARAMETERS***
41
41
**********************************
42
- End-Use Option,1, ---[-] Direct-Use
43
- Power Plant Type, 1, ---[-] Subcritical ORC
44
- Circulation Pump Efficiency,.8, ---[-]
45
- Utilization Factor,.9, ---[-]
46
- End-Use Efficiency Factor,0.9, ---[-]
47
- Surface Temperature,20, ---[deg.C]
48
- Ambient Temperature,20, ---[deg.C]
49
- Electricity Rate,0.1, ---Electricity rate for pumping power [$/kWh]
42
+ End-Use Option,1, ---[-] Electricity
43
+ Power Plant Type, 1, ---[-] Subcritical ORC
44
+ Circulation Pump Efficiency,.8, ---[-]
45
+ Utilization Factor,.9, ---[-]
46
+ End-Use Efficiency Factor,0.9, ---[-]
47
+ Surface Temperature,20, ---[deg.C]
48
+ Ambient Temperature,20, ---[deg.C]
49
+ Electricity Rate,0.1, ---Electricity rate for pumping power [$/kWh]
50
50
51
51
***FINANCIAL PARAMETERS***
52
52
**************************
53
- Plant Lifetime,30, ---[years]
54
- Economic Model,1, ---[-] Fixed Charge Rate Model
55
- Fixed Charge Rate,.05, ---[-] between 0 and 1
56
- Inflation Rate During Construction,0, ---[-]
53
+ Plant Lifetime,30, ---[years]
54
+ Economic Model,1, ---[-] Fixed Charge Rate Model
55
+ Fixed Charge Rate,.05, ---[-] between 0 and 1
56
+ Inflation Rate During Construction,0, ---[-]
57
57
58
58
***CAPITAL AND O&M COST PARAMETERS***
59
59
*************************************
0 commit comments