Notifications
You must be signed in to change notification settings - Fork 4
Expand file tree
/
Copy pathmake_units_cxc.py
More file actions
99 lines (78 loc) · 2.71 KB
/
make_units_cxc.py
File metadata and controls
99 lines (78 loc) · 2.71 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
# Licensed under a 3-clause BSD style license - see LICENSE.rst
"""
Create the default unit system as found in the CXC telemetry FITS files.
"""
import argparse
import glob
import os
import pickle
import re
import pyfits
import pyyaks
from cheta import fetch, file_defs
from cheta.converters import CXC_TO_MSID, _get_deahk_cols
def get_options(args=None):
parser = argparse.ArgumentParser()
parser.add_argument(
"--dry-run",
action="store_true",
help="Dry run (no actual file or database updates)",
)
return parser.parse_args(args)
opt = get_options()
ft = fetch.ft
arch_files = pyyaks.context.ContextDict(
"update_archive.arch_files",
basedir=os.path.join(file_defs.SKA, "data", "eng_archive"),
)
arch_files.update(file_defs.arch_files)
units = {}
# CXC content types
contents = set(fetch.content.values())
for content in sorted(contents):
if content.startswith("dp_"):
continue
ft["content"] = content
dir_ = arch_files["archrootdir"].abs
print("Finding units in", dir_)
# Get the most recent directory
years = sorted([yr for yr in os.listdir(dir_) if re.match(r"\d{4}", yr)])
dir_ = os.path.join(dir_, years[-1])
days = sorted([day for day in os.listdir(dir_) if re.match(r"\d{3}", day)])
dir_ = os.path.join(dir_, days[-1])
files = glob.glob(os.path.join(dir_, "*.fits.gz"))
if not files:
print("No {} fits files in {}".format(content, dir_))
continue
print("Reading", files[0])
hdus = pyfits.open(os.path.join(dir_, files[0]))
cols = hdus[1].columns
for msid, unit in zip(cols.names, cols.units):
unit = unit.strip()
if unit:
msid = msid.upper()
if content in CXC_TO_MSID:
msid = CXC_TO_MSID[content].get(msid, msid)
if re.match(r"(orbit|lunar|solar|angle)ephem", content):
msid = "{}_{}".format(content.upper(), msid)
units[msid.upper()] = unit
hdus.close()
# AFAIK these are the only temperature MSIDs that are actually temperature
# differences and which require special handling on conversion.
relative_temp_msids = (
"OHRMGRD3", # RT 500 TO RT 502: CAP GRADIENT MONITOR
"OHRMGRD6", # RT 503 TO RT 501: CAP GRADIENT MONITOR
"OOBAGRD3", # RT 505 TO RT 504: PERISCOPE GRADIENT MONITOR
"OOBAGRD6", # RT 507 TO RT 506: PERISCOPE GRADIENT MONITOR
)
for msid in relative_temp_msids:
units[msid] = "deltaK"
units["3MRMMXMV"] = "PWM"
# Use info about DEA HK telemetry from converters to add units
for col in _get_deahk_cols():
if "unit" in col:
units[col["name"].upper()] = col["unit"]
if not opt.dry_run:
pickle.dump(units, open("units_cxc.pkl", "wb"))
else: