Skip to content

Commit 83429dd

Browse files
Merge pull request #256 from srobo/kit-details-from-rules
Kit details from rules
2 parents 8e70069 + 836ca1c commit 83429dd

File tree

3 files changed

+32
-9
lines changed

3 files changed

+32
-9
lines changed

_data/sidebar_tree.yaml

Lines changed: 2 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -27,6 +27,8 @@ tree:
2727
title: Servo Board
2828
- url: /kit/wifi
2929
title: WiFi
30+
- url: /kit/safety-regulations
31+
title: Safety Regulations
3032
- url: /programming/
3133
title: Programming
3234
tree:

kit/index.md

Lines changed: 2 additions & 9 deletions
Original file line numberDiff line numberDiff line change
@@ -40,11 +40,8 @@ As well as the aforementioned boards the kit also contains the following items.
4040
| USB Memory Stick | 1 | Kingston Datatraveler 16GB SE9H | [DTSE9H/16GB][DTSE9H-16GB] |
4141
| Standard USB cable | 3 | Standard USB A to B connector | N/A | For connecting the ruggeduino (via a hub) and USB hubs to the ODROID
4242
| Micro USB cable | 5 | Standard USB A to Micro USB B | N/A | For connecting the motor boards, servo boards and power board to the ODROID
43-
| Blue Hook-up Wire | 1 | 2.5m<br />0.5mm<sup>2</sup><br />4A | [RS 361-585][RS-361-585] | General purpose wire
44-
| Yellow Hook-up Wire | 1 | 2.5m<br />0.5mm<sup>2</sup><br />4A | [RS 361-636][RS-361-636] | General purpose wire
45-
| Green Power Wire | 1 | 2.5m<br />1mm<sup>2</sup><br />10A | [RS 748-2042][RS-748-2042] | To connect the motors to the motor boards only
46-
| Red Power Wire | 1 | 2.5m<br />1mm<sup>2</sup><br />10A | [RS 361-759][RS-361-759] | To connect power from the power board to the motor/servo boards
47-
| Black Power Wire | 1 | 2.5m<br />1mm<sup>2</sup><br />10A | [RS 361-715][RS-361-715] | To connect power from the power board to the motor/servo boards
43+
| Coloured Power Wire | 1 | | | To connect power from the power board to the motor/servo boards
44+
| Black Power Wire | 1 | | | To connect power from the power board to the motor/servo boards
4845
| CamCon | 10 | 2 way<br />7.5mm<br />12A | [Farnell 3882275][F-3882275] | To connect 12V from the power board to the motor and servo boards
4946
| MiniCamCon | 7 | 2 way<br />5mm<br />12A | [Farnell 3881854][F-3881854] | To connect motors to the motor boards, and to connect an external power switch
5047
| MicroCamCon | 1 | 2 way<br />3.81mm<br />12A | [Farnell 1717047][F-1717047] | To connect a 5V component to the power board or to connect an external start button
@@ -60,11 +57,7 @@ As well as the aforementioned boards the kit also contains the following items.
6057
[F-3881854]: https://uk.farnell.com/3881854
6158
[F-1717047]: https://uk.farnell.com/1717047
6259
[F-2103271]: https://uk.farnell.com/2103271
63-
[RS-361-715]: https://uk.rs-online.com/web/p/products/361-715
64-
[RS-361-759]: https://uk.rs-online.com/web/p/products/361-759
6560
[RS-748-2042]: https://uk.rs-online.com/web/p/products/748-2042
66-
[RS-361-585]: https://uk.rs-online.com/web/p/products/361-585
67-
[RS-361-636]: https://uk.rs-online.com/web/p/products/361-636
6861
[EB-230435]: https://www.ebuyer.com/230435-logitech-c270-hd-webcam-720p-hd-video-960-000582
6962
[G138960965859]: https://www.hardkernel.com/main/products/prdt_info.php?g_code=G138960965859
7063
[0000153]: https://www.modelsport.co.uk/overlander-lipo-safe-sack/rc-car-products/38313

kit/safety-regulations.md

Lines changed: 28 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -0,0 +1,28 @@
1+
---
2+
layout: page
3+
title: Safety Regulations
4+
---
5+
6+
# Safety Regulations
7+
8+
To maintain safety at the competition, all robots at the event are required to pass the safety regulations that are listed below. Robots that do not comply to these rules will not be permitted to compete.
9+
10+
These regulations are intended to identify a base level of safety — the inspector will use their own judgement and common sense when assessing your robot, and your robot may be judged to be unsafe for reasons or features not listed here.
11+
12+
We recommend that you bear these regulations in mind during development too, although it’s not always possible to meet them while building and testing your robot.
13+
14+
The following procedure will be used when testing a robot:
15+
- Check that there is a battery installed in the robot.
16+
- Check that any additional power sources have already been authorised.
17+
- Check that the battery cable originally provided by Student Robotics is being used to connect the power board to the battery. If not, check that the replacement has suitable rating and quality.
18+
- Leaving the battery physically installed, unplug the deans connector.
19+
- Check the battery’s mounting holds the battery securely, and does not expose the battery to sharp edges.
20+
- Check that the battery’s casing is rigid, and strong – i.e. bubble wrap is not suitable.
21+
- Locate the large green power connector that connects the battery to the power board. In turn, give each of the wires that enter it a gentle tug. The cables must not move.
22+
- Check that there is not an excessive amount of unshielded wire protruding from the large green power connector.
23+
- Check that the cable between the large green power connector and the deans connector is not damaged. The sheath must not have any holes in etc.
24+
- Check that the cables between the power board and body of the battery do not pass through areas of the robot that could cause them to be damaged by moving mechanical parts.
25+
- Check that only the power board is connected to the battery (if the deans connector were currently connected).
26+
- Check that the power switch on the power board is easily accessible.
27+
- Check that all electronics are securely fixed to the robot.
28+
- Check for unreasonably sharp edges and dangerous moving parts.

0 commit comments

Comments
 (0)