STATBUS Troubleshooting Guide

Production Testing Issues

❌ DON'T: Use pnpm run prod-local for production issue testing

If you run pnpm run prod-local and test at http://localhost:3001, you'll encounter:

CORS Errors:

Access to fetch at 'http://local.statbus.org:3010/rest/rpc/auth_status' from origin 'http://localhost:3001' has been blocked by CORS policy

Why this happens:

  • App runs on localhost:3001 (different origin)
  • API calls go to local.statbus.org:3010 (different origin)
  • Browser blocks cross-origin requests
  • Next.js proxy rewrites only work in development mode
  • Production builds expect unified URL architecture

✅ DO: Use Docker for production testing

# Stop any running app
./devops/manage-statbus.sh stop app

# Rebuild with latest changes
docker compose build app --no-cache

# Start production-like environment  
./devops/manage-statbus.sh start app

# Test at unified URL
open http://local.statbus.org:3010

Why this works:

  • ✅ Uses unified URL (local.statbus.org:3010 for everything)
  • ✅ Caddy handles /rest API forwarding
  • ✅ No CORS issues (same origin)
  • ✅ Exact production architecture
  • ✅ Real production builds

Navigation Hang Issues

If you see the page stuck on "Loading application..." at /login after successful authentication:

Root Cause: Navigation deadlock between Next.js router and page rendering

  • Navigation machine commands router.push('/')
  • Root page blocks rendering on data loading
  • Next.js waits for page to render before completing navigation
  • Navigation machine waits for pathname change
  • Deadlock occurs

How to Test Locally:

  1. Use Docker: ./devops/manage-statbus.sh start app
  2. Open http://local.statbus.org:3010 in browser
  3. Enable debug: localStorage.setItem('debug', 'true')
  4. Login and observe if it hangs at /login

Console Logs to Watch:

  • [DEBUG] [nav-machine:redirectingFromLogin] Redirecting away from /login to /
  • If URL stays at /login → bug reproduced
  • If URL changes to / → navigation completed successfully

Docker Container Issues

Database Connection Issues:

# Check all services
docker compose ps

# Should show:
# statbus-local-db     - healthy
# statbus-local-rest   - running  
# statbus-local-proxy  - running
# statbus-local-app    - running

If services aren't healthy:

# Check logs
docker compose logs db --tail=50
docker compose logs rest --tail=50
docker compose logs app --tail=50

# Restart services
./devops/manage-statbus.sh restart

Environment Configuration Issues

Missing .env file:

ERROR: ../.env file not found!
Please run: ./devops/manage-statbus.sh generate-config

Solution:

./devops/manage-statbus.sh generate-config

DNS resolution issues:

# Test DNS resolution
host local.statbus.org
# Should return: local.statbus.org has address 127.0.0.1

# If not working, add to /etc/hosts:
echo "127.0.0.1 local.statbus.org" | sudo tee -a /etc/hosts

Common Patterns

Fast Development Iteration

For navigation/auth/state machine issues:

# 1. Make code changes
# 2. Rebuild container (takes ~2-3 minutes)
docker compose build app --no-cache

# 3. Start and test
./devops/manage-statbus.sh start app

# 4. Test at unified URL
open http://local.statbus.org:3010

Debug State Machines

// In browser console
localStorage.setItem('debug', 'true')
// Reload page to see detailed state machine logs

Quick Health Check

# Test if app responds
curl -I http://local.statbus.org:3010/

# Should return:
# HTTP/1.1 200 OK  (or 307 redirect to /login)

When to Use Which Testing Method

Issue Type Use Access URL
Navigation, auth, state machines Docker http://local.statbus.org:3010
API calls, data loading Docker http://local.statbus.org:3010
Production build verification Docker http://local.statbus.org:3010
Bundle size analysis Either localhost:3001 or local.statbus.org:3010
Quick build test pnpm run prod-local http://localhost:3001
Development pnpm run dev http://localhost:3000

Remember: Docker for Real Production Testing

The key insight is that STATBUS uses a unified URL architecture in production:

  • Single domain handles both app and API
  • Caddy proxy routes /rest/* to PostgREST
  • This eliminates CORS issues and matches production exactly