You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Copy file name to clipboardExpand all lines: guides/troubleshoot/recording_quality_eeg/index.rst
+6-2Lines changed: 6 additions & 2 deletions
Display the source diff
Display the rich diff
Original file line number
Diff line number
Diff line change
@@ -1,12 +1,13 @@
1
1
.. _recording_quality_eeg:
2
2
3
3
Recording Quality EEG
4
-
##########
4
+
######################
5
5
6
6
This guide will help you set up and verify your EEG signals using the BioAmp Hardware and Chords software.
7
7
8
8
Step 1: Skin Preparation
9
9
========================
10
+
10
11
Proper skin preparation is crucial before recording any biopotential signal, whether it is Electrocardiography (ECG), Electromyography (EMG), Electroencephalography (EEG), or Electrooculography (EOG). It helps to:
11
12
12
13
- Clean the skin surface
@@ -19,6 +20,7 @@ Proper skin preparation is crucial before recording any biopotential signal, whe
19
20
20
21
Step 2: Connecting BioAmp Cables to the Hardware
21
22
================================================
23
+
22
24
Connect the BioAmp cables to the appropriate input channels of your EEG device. Make sure the ground and reference electrodes are securely connected to the body.
23
25
24
26
.. figure:: ../media/connections.*
@@ -29,6 +31,7 @@ Connect the BioAmp cables to the appropriate input channels of your EEG device.
29
31
30
32
Step 3: Attaching Gel Electrodes on Targeted Areas
Place the gel-based electrodes firmly on the targeted scalp regions—typically the frontal (e.g., Fp1, Fp2) or occipital (e.g., O1, O2) lobes—depending on your signal of interest. Ensure that the electrodes have good skin contact and are not loose.
33
36
34
37
.. figure:: ../media/eeg_place.*
@@ -42,12 +45,13 @@ Step 4: Open Chords Software to Visualize Signals
42
45
43
46
1. Open a Chromium-based browser such as **Google Chrome**, **Microsoft Edge**, **Opera**, or **Brave**.
44
47
2. Go to: `https://chords.upsidedownlabs.tech <https://chords.upsidedownlabs.tech>`_
45
-
3. Click on **Visualize Now** then **Chords-Visualizer**.
48
+
3. Click on the **Visualize Now** button on the home page and then click on the **Chords-Visualizer** button on the next page.
46
49
4. Connect your device via **Serial** by selecting your device's port.
47
50
5. Begin real-time visualization of your EEG signals.
48
51
49
52
Step 5: How to Check Whether the Signals Are Correct
0 commit comments