Mutual Inductance Program V3.1
Copyright (c) 1998, 1999, 2000 by Mark S. Rzeszotarski, Ph.D.
Solenoidal Primary Coil Geometry
Primary coil inside diameter (inches)= 4.400
Primary coil outside diameter (inches)= 4.400
Number of primary coil turns = 13.750
Last turn elevation in inches = 3.600
Wire diameter (inches)= .0800
Solenoidal Secondary Coil Geometry
Secondary coil diameter (inches)= 2.520
Secondary coil height (inches)= 16.400
Number of secondary coil turns = 2000.000
Secondary coil wire diameter (inches)= .0079
Calculational Results
Primary coil inductance in microhenries: Lp = 16.40
Secondary coil inductance in microhenries: Ls = 36410.54
Figure of Merit (square root of Ls/Lp) = 47.12
Primary coil wire length in feet = 15.82
Secondary coil wire length in feet = 1319.47
DC secondary resistance in ohms: 220.63
Secondary coil distributed capacitance in picofarads: 6.18
(Medhurst formula, assumes one end of secondary is grounded)
Mutual Inductance Results
Position is the secondary coil bottom wire position in inches
above the bottom wire of the primary coil.
A negative value means the bottom wire of the
secondary is below the bottom wire of the primary.
A positive value means that the bottom wire of the
secondary is above the bottom wire of the primary coil.
M = Mutual Inductance in microhenries
K = Coefficient of Coupling: K = M / square root ( Lp x Ls )
Position M K
-1.000 232.859 .3014
-.500 222.983 .2886
.000 209.272 .2708
.500 191.347 .2476
1.000 169.942 .2199
1.500 146.398 .1895
2.000 122.073 .1580
Operating Characteristics
Ctoroid is the added capacitance of the top terminal.
Fres is the resonant operating frequency in kilohertz.
Cpri is the required primary capacitance in nanofarads.
Zpri is the primary surge impedance in ohms.
Zsec is the secondary surge impedance in ohms.
Qsec is the secondary coil quality factor Q.
Rac is the secondary coil RF resistance in ohms.
Ctoroid(pF) .0 5.0 10.0 15.0 20.0 25.0 30.0 35.0
Fres(kHz) 335.5 249.4 207.3 181.2 163.0 149.4 138.7 130.0
Cpri (nF) 13.73 24.83 35.93 47.04 58.14 69.24 80.34 91.45
Zpri(ohms) 34.6 25.7 21.4 18.7 16.8 15.4 14.3 13.4
Zsec(ohms) 76749. 57065. 47436. 41461. 37292. 34172. 31723. 29735.
Qsec 109.6 81.9 68.3 59.7 53.8 49.3 45.8 42.9
Rac (ohms) 700.5 696.6 694.8 694.1 693.6 693.3 693.0 692.8