| 1 | +# Copyright (c) 2025 Analog Devices, Inc. |
| 2 | +# SPDX-License-Identifier: Apache-2.0 |
| 3 | + |
| 4 | +description: | |
| 5 | + Bindings for the ADI AD7124 Analog-to-Digital Converter. |
| 6 | +
|
| 7 | +compatible: adi,ad7124-adc |
| 8 | + |
| 9 | +include: [adc-controller.yaml, spi-device.yaml] |
| 10 | + |
| 11 | +properties: |
| 12 | + |
| 13 | + reference-enable: |
| 14 | + type: boolean |
| 15 | + description: | |
| 16 | + Enable internal reference for AD7124 |
| 17 | + - true: Enable internal reference |
| 18 | + - false: Disable internal reference |
| 19 | +
|
| 20 | + filter-type-mask: |
| 21 | + type: int |
| 22 | + default: 0 |
| 23 | + description: | |
| 24 | + Filter type for AD7124: |
| 25 | + Each bit set in this mask enables the filter type, |
| 26 | + with the 0th bit corresponding to the 0th channel, |
| 27 | + the 1st bit to the 1st channel, and so on. |
| 28 | + - 0 means AD7124_FILTER_SINC4 |
| 29 | + - 1 means AD7124_FILTER_SINC3 |
| 30 | + The default is set to 0 because the filter type is set to SINC4 |
| 31 | + for all filter setups upon power-up or after reset. |
| 32 | + Therefore, this setting is considered the default for all channels. |
| 33 | +
|
| 34 | + bipolar-mask: |
| 35 | + type: int |
| 36 | + default: 0xFFFF |
| 37 | + description: | |
| 38 | + Bipolar configuration for AD7124 |
| 39 | + Each bit set in this mask enables the polarity, |
| 40 | + with the 0th bit corresponding to the 0th channel, |
| 41 | + the 1st bit to the 1st channel, and so on. |
| 42 | + - 0 Unipolar operation selection |
| 43 | + - 1 Bipolar operation selection |
| 44 | + The default is set to 0xFFFF because the bipolar configuration |
| 45 | + is activated for all configuration setups upon power-up or after reset. |
| 46 | + Therefore, this setting is considered the default for all channels. |
| 47 | +
|
| 48 | + inbuf-enable-mask: |
| 49 | + type: int |
| 50 | + default: 0xFFFF |
| 51 | + description: | |
| 52 | + Input buffer configuration for AD7124 |
| 53 | + Each bit set in this mask enables the input buffer, |
| 54 | + with the 0th bit corresponding to the 0th channel, |
| 55 | + the 1st bit to the 1st channel, and so on. |
| 56 | + - 0 Analog input pin is unbuffered |
| 57 | + - 1 Analog input pin is buffered |
| 58 | + The default is set to 0xFFFF because the analog input buffer |
| 59 | + is enabled for all configuration setups upon power-up or after reset. |
| 60 | + Therefore, this setting is considered the default for all channels. |
| 61 | +
|
| 62 | + refbuf-enable-mask: |
| 63 | + type: int |
| 64 | + default: 0 |
| 65 | + description: | |
| 66 | + Reference buffer configuration for AD7124 |
| 67 | + Each bit set in this mask enables the reference buffer, |
| 68 | + with the 0th bit corresponding to the 0th channel, |
| 69 | + the 1st bit to the 1st channel, and so on. |
| 70 | + - 0 Reference input pin is unbuffered |
| 71 | + - 1 Reference input pin is buffered |
| 72 | + The default is set to 0 because the reference input buffer |
| 73 | + is enabled for all configuration setups upon power-up or after reset. |
| 74 | + Therefore, this setting is considered the default for all channels. |
| 75 | +
|
| 76 | + adc-mode: |
| 77 | + type: int |
| 78 | + enum: [0, 1, 2, 3, 4, 5, 6, 7, 8] |
| 79 | + default: 0 |
| 80 | + description: | |
| 81 | + ADC operating mode for AD7124 |
| 82 | + - 0 AD7124_CONTINUOUS |
| 83 | + - 1 AD7124_SINGLE |
| 84 | + - 2 AD7124_STANDBY |
| 85 | + - 3 AD7124_POWER_DOWN |
| 86 | + - 4 AD7124_IDLE |
| 87 | + - 5 AD7124_IN_ZERO_SCALE_OFF |
| 88 | + - 6 AD7124_IN_FULL_SCALE_GAIN |
| 89 | + - 7 AD7124_SYS_ZERO_SCALE_OFF |
| 90 | + - 8 AD7124_SYS_ZERO_SCALE_GAIN |
| 91 | + The default is set to 0 because the continuous conversion mode |
| 92 | + is enabled for control setup upon power-up or after reset. |
| 93 | +
|
| 94 | + power-mode: |
| 95 | + type: int |
| 96 | + enum: [0, 1, 2] |
| 97 | + default: 0 |
| 98 | + description: | |
| 99 | + Power mode of the ADC for AD7124 |
| 100 | + - 0 AD7124_LOW_POWER_MODE |
| 101 | + - 1 AD7124_MID_POWER_MODE |
| 102 | + - 2 AD7124_HIGH_POWER_MODE |
| 103 | + The default is set to 0 because the low power mode |
| 104 | + is enabled for control setup upon power-up or after reset. |
| 105 | +
|
| 106 | + active-device: |
| 107 | + type: int |
| 108 | + enum: [0, 1] |
| 109 | + required: true |
| 110 | + description: | |
| 111 | + Active device for AD7124 |
| 112 | + - 0 ID_AD7124_4 |
| 113 | + - 1 ID_AD7124_8 |
| 114 | +
|
| 115 | + "#io-channel-cells": |
| 116 | + const: 1 |
| 117 | + |
| 118 | +io-channel-cells: |
| 119 | + - input |
0 commit comments