Describe the bug

I try to run zephyr/samples/drivers/display sample application function on STM32H747I-DISCO with NT35510 panel shell use st_b_lcd40_dsi1_mb1166_a09 and the display_blanking_off() function is not working because no panel controller forward to.
And I found related issue #68527, and followed the steps and get the same result, it’s still not working

1.add display-controller in app.overly and make sure display-controller = < &nt35510 > appear in ltdc DTS in zephyr.dts

&ltdc {
	display-controller = <&nt35510>;
};

2.Change initialization priority implement as #68527 and check initialization priority

  __init___device_dts_ord_137: mipi_dsi_stm32_init(__device_dts_ord_137)
  __init___device_dts_ord_140: nt35510_init(__device_dts_ord_140)
  __init___device_dts_ord_141: stm32_ltdc_init(__device_dts_ord_141)
  1. I get Display device nt35510@0 not ready
[00:00:01.222,000] <err> dsi_stm32: Transfer failed! (3)
[00:00:01.222,000] <err> nt35510: Failed reading ID (-5)
[00:00:01.222,000] <err> nt35510: Panel ID check failed! (-5)
*** Booting Zephyr OS build v3.7.0-2665-gcc544803811b ***
[00:00:01.222,000] <inf> sample: Display sample for display-controller@50001000
[00:00:01.234,000] <inf> display_stm32_ltdc: config name display-controller@50001000
[00:00:01.234,000] <err> display_stm32_ltdc: Display device nt35510@0 not ready

To Reproduce
Run zephyr/samples/drivers/display sample application function on STM32H747I-DISCO with NT35510 panel shell use st_b_lcd40_dsi1_mb1166_a09

build command
west build -t initlevels --pristine -b stm32h747i_disco/stm32h747xx/m7 zephyr/samples/drivers/display -DSHIELD=st_b_lcd40_dsi1_mb1166_a0

Expected behavior
display_blanking_off() function work without error

Impact
When developing project,it's not able to use this API to control the backlight. System power saving and suspend modes will not be implemented.

Logs and console output

<err> display_stm32_ltdc: There is no panel controller to forward blanking_off call to name 

Environment (please complete the following information):

Microcontroller: STM32H747I
Zephyr Version: Zephyr main branch Commit cc54480
OS: Ubuntu 23.10