Skip to content

Latest commit

 

History

History
58 lines (41 loc) · 2 KB

File metadata and controls

58 lines (41 loc) · 2 KB
title description addedAt pageClass
Immax 07527L control via MQTT
Integrate your Immax 07527L via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway.
2025-05-01 10:59:09 -0700
device-page

Immax 07527L

Model 07527L
Vendor Immax
Description NEO Smart PIR sensor 2v1 Zigbee 3.0
Exposes occupancy, illuminance, battery
Picture Immax 07527L

Options

How to use device type specific configuration

  • illuminance_calibration: Calibrates the illuminance value (percentual offset), takes into effect on next report of device. The value must be a number.

Exposes

Occupancy (binary)

Indicates whether the device detected occupancy. Value can be found in the published state on the occupancy property. It's not possible to read (/get) or write (/set) this value. If value equals true occupancy is ON, if false OFF.

Illuminance (numeric)

Measured illuminance. Value can be found in the published state on the illuminance property. It's not possible to read (/get) or write (/set) this value. The unit of this value is lx.

Battery (numeric)

Remaining battery in %, can take up to 24 hours before reported. Value can be found in the published state on the battery property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 100. The unit of this value is %.