@@ -128,6 +128,19 @@ class BoschControlSequenceOfOperation(t.enum8):
128128
)
129129

130130

131+
def get_attribute_id_or_name(
132+
attribute: ZCLAttributeDef, attributes: dict[str | int, Any] | list[int | str]
133+
) -> int | str | None:
134+
"""Return the attribute id/name when the id/name of the attribute is in the attributes list or None otherwise."""
135+
136+
if attribute.id in attributes:
137+
return attribute.id
138+
elif attribute.name in attributes:
139+
return attribute.name
140+
else:
141+
return None
142+
143+
131144
class BoschThermostatCluster(CustomCluster, Thermostat):
132145
"""Bosch thermostat cluster."""
133146

@@ -196,24 +209,21 @@ async def write_attributes(
196209
- do not write it to the device since it is not supported
197210
- keep the value to be converted to the supported operating_mode
198211
"""
199-
if SYSTEM_MODE_ATTR.id in attributes:
200-
remaining_attributes.pop(SYSTEM_MODE_ATTR.id)
201-
system_mode_value = attributes.get(SYSTEM_MODE_ATTR.id)
202-
elif SYSTEM_MODE_ATTR.name in attributes:
203-
remaining_attributes.pop(SYSTEM_MODE_ATTR.name)
204-
system_mode_value = attributes.get(SYSTEM_MODE_ATTR.name)
212+
system_mode_attribute_id = get_attribute_id_or_name(
213+
SYSTEM_MODE_ATTR, attributes
214+
)
215+
if system_mode_attribute_id is not None:
216+
remaining_attributes.pop(system_mode_attribute_id)
217+
system_mode_value = attributes.get(system_mode_attribute_id)
205218

206219
"""Check if operating_mode_attr is being written (can be numeric or string).
207220
- ignore incoming operating_mode when system_mode is also written
208221
- system_mode has priority and its value would be converted to operating_mode
209222
- add resulting system_mode to the internal zigpy Cluster cache
210223
"""
211-
operating_mode_attribute_id = None
212-
if operating_mode_attr.id in attributes:
213-
operating_mode_attribute_id = operating_mode_attr.id
214-
elif operating_mode_attr.name in attributes:
215-
operating_mode_attribute_id = operating_mode_attr.name
216-
224+
operating_mode_attribute_id = get_attribute_id_or_name(
225+
operating_mode_attr, attributes
226+
)
217227
if operating_mode_attribute_id is not None:
218228
if system_mode_value is not None:
219229
operating_mode_value = remaining_attributes.pop(
@@ -259,35 +269,32 @@ async def write_attributes(
259269
"""Sync system_mode with ctrl_sequence_of_oper."""
260270
ctrl_sequence_of_oper_attr = Thermostat.AttributeDefs.ctrl_sequence_of_oper
261271

262-
ctrl_sequence_of_oper_value = None
263-
if ctrl_sequence_of_oper_attr.id in attributes:
264-
ctrl_sequence_of_oper_value = attributes.get(
265-
ctrl_sequence_of_oper_attr.id
266-
)
267-
elif ctrl_sequence_of_oper_attr.name in attributes:
272+
ctrl_sequence_of_oper_attribute_id = get_attribute_id_or_name(
273+
ctrl_sequence_of_oper_attr, attributes
274+
)
275+
if ctrl_sequence_of_oper_attribute_id is not None:
268276
ctrl_sequence_of_oper_value = attributes.get(
269-
ctrl_sequence_of_oper_attr.name
270-
)
271-
272-
if ctrl_sequence_of_oper_value is not None:
273-
successful_r, failed_r = await super().read_attributes(
274-
[operating_mode_attr.name], True, False, manufacturer
277+
ctrl_sequence_of_oper_attribute_id
275278
)
276-
if operating_mode_attr.name in successful_r:
277-
operating_mode_attr_value = successful_r.pop(
278-
operating_mode_attr.name
279+
if ctrl_sequence_of_oper_value is not None:
280+
successful_r, failed_r = await super().read_attributes(
281+
[operating_mode_attr.name], True, False, manufacturer
279282
)
280-
if operating_mode_attr_value == BoschOperatingMode.Manual:
281-
new_system_mode_value = Thermostat.SystemMode.Heat
282-
if (
283-
ctrl_sequence_of_oper_value
284-
== BoschControlSequenceOfOperation.Cooling
285-
):
286-
new_system_mode_value = Thermostat.SystemMode.Cool
287-
288-
self._update_attribute(
289-
SYSTEM_MODE_ATTR.id, new_system_mode_value
283+
if operating_mode_attr.name in successful_r:
284+
operating_mode_attr_value = successful_r.pop(
285+
operating_mode_attr.name
290286
)
287+
if operating_mode_attr_value == BoschOperatingMode.Manual:
288+
new_system_mode_value = Thermostat.SystemMode.Heat
289+
if (
290+
ctrl_sequence_of_oper_value
291+
== BoschControlSequenceOfOperation.Cooling
292+
):
293+
new_system_mode_value = Thermostat.SystemMode.Cool
294+
295+
self._update_attribute(
296+
SYSTEM_MODE_ATTR.id, new_system_mode_value
297+
)
291298

292299
"""Write the remaining attributes to thermostat cluster."""
293300
if remaining_attributes:
@@ -310,16 +317,14 @@ async def read_attributes(
310317

311318
successful_r, failed_r = {}, {}
312319
remaining_attributes = attributes.copy()
313-
system_mode_attribute_id = None
314320

315321
"""Check if SYSTEM_MODE_ATTR is being read (can be numeric or string)."""
316-
if SYSTEM_MODE_ATTR.id in attributes:
317-
system_mode_attribute_id = SYSTEM_MODE_ATTR.id
318-
elif SYSTEM_MODE_ATTR.name in attributes:
319-
system_mode_attribute_id = SYSTEM_MODE_ATTR.name
320-
321-
"""Read operating_mode instead and convert it to system_mode."""
322+
system_mode_attribute_id = get_attribute_id_or_name(
323+
SYSTEM_MODE_ATTR, attributes
324+
)
322325
if system_mode_attribute_id is not None:
326+
"""Read operating_mode instead and convert it to system_mode."""
327+
323328
remaining_attributes.remove(system_mode_attribute_id)
324329

325330
ctrl_sequence_of_oper_attr = Thermostat.AttributeDefs.ctrl_sequence_of_oper

0 commit comments