Notifications
You must be signed in to change notification settings - Fork 991
Labels
device support requestThis requests support for a new deviceThis requests support for a new device
Description
Problem description
Since 2026.2.0, my zha-toolkit read attributes commands fail with a backtrace in the logs that shows an invalid manufacturer code.
File "/opt/homeassistant/.homeassistant/custom_components/zha_toolkit/utils.py", line 1211, in cluster_read_attributes
return await cluster.read_attributes(attrs, manufacturer=manufacturer)
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
File "/opt/homeassistant/venv-3.13/lib/python3.13/site-packages/zigpy/zcl/__init__.py", line 965, in read_attributes
attr_def = self.find_attribute(attribute, manufacturer_code=manufacturer)
File "/opt/homeassistant/venv-3.13/lib/python3.13/site-packages/zigpy/zcl/__init__.py", line 513, in find_attribute
raise KeyError(manufacturer_code)
KeyError: 0
Solution description
I figured that the attributes in error where attributes of the cluster Metering of the ZLinky_TIC and added them in a custom_quirk.
It solved my problem.
Screenshots/Video
Screenshots/Video
None available.
Diagnostics information
zha-4e7438fded8a244ee2b9a6fade3a1023-LiXee ZLinky_TIC-dc486567f5fcf9be70dd10399a1ebaaf(1).json
Device signature
Device signature
{
"node_descriptor": {
"logical_type": 1,
"complex_descriptor_available": 0,
"user_descriptor_available": 0,
"reserved": 0,
"aps_flags": 0,
"frequency_band": 8,
"mac_capability_flags": 142,
"manufacturer_code": 4151,
"maximum_buffer_size": 127,
"maximum_incoming_transfer_size": 200,
"server_mask": 11264,
"maximum_outgoing_transfer_size": 200,
"descriptor_capability_field": 0
},
"endpoints": {
"1": {
"profile_id": "0x0104",
"device_type": "0x0053",
"input_clusters": [
"0x0000",
"0x0001",
"0x0003",
"0x0702",
"0x0b01",
"0x0b04",
"0xff66"
],
"output_clusters": [
"0x0019"
]
},
"242": {
"profile_id": "0xa1e0",
"device_type": "0x0061",
"input_clusters": [
"0x0021"
],
"output_clusters": [
"0x0021"
]
}
},
"manufacturer": "LiXee",
"model": "ZLinky_TIC",
"class": "zlinky.ZLinkyTICFWV12"
}
Logs
Logs
2026-02-07 14:19:31.061 ERROR (MainThread) [homeassistant.helpers.script.websocket_api_script] websocket_api script: Error executing scrip\
t. Unexpected error for call_service at pos 1: 0
Traceback (most recent call last):
File "/opt/homeassistant/venv-3.13/lib/python3.13/site-packages/homeassistant/helpers/script.py", line 531, in _async_step
await getattr(self, handler)()
File "/opt/homeassistant/venv-3.13/lib/python3.13/site-packages/homeassistant/helpers/script.py", line 1018, in _async_step_call_service
response_data = await self._async_run_long_action(
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
...<9 lines>...
)
^
File "/opt/homeassistant/venv-3.13/lib/python3.13/site-packages/homeassistant/helpers/script.py", line 631, in _async_run_long_action
return await long_task
^^^^^^^^^^^^^^^
File "/opt/homeassistant/venv-3.13/lib/python3.13/site-packages/homeassistant/core.py", line 2817, in async_call
response_data = await coro
^^^^^^^^^^
File "/opt/homeassistant/venv-3.13/lib/python3.13/site-packages/homeassistant/core.py", line 2860, in _execute_service
return await target(service_call)
^^^^^^^^^^^^^^^^^^^^^^^^^^
File "/opt/homeassistant/.homeassistant/custom_components/zha_toolkit/__init__.py", line 819, in toolkit_service
raise handler_exception
File "/opt/homeassistant/.homeassistant/custom_components/zha_toolkit/__init__.py", line 771, in toolkit_service
handler_result = await handler(
^^^^^^^^^^^^^^
...<8 lines>...
)
^
File "/opt/homeassistant/.homeassistant/custom_components/zha_toolkit/__init__.py", line 906, in command_handler_default
return await default.default(
^^^^^^^^^^^^^^^^^^^^^^
app, listener, ieee, cmd, data, service, params, event_data
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
)
^
File "/opt/homeassistant/.homeassistant/custom_components/zha_toolkit/default.py", line 51, in default
await handler(app, listener, ieee, cmd, data, service, params, event_data)
File "/opt/homeassistant/.homeassistant/custom_components/zha_toolkit/zcl_attr.py", line 311, in attr_read
await attr_write(*args, **kwargs)
File "/opt/homeassistant/.homeassistant/custom_components/zha_toolkit/zcl_attr.py", line 371, in attr_write
result_read = await u.cluster_read_attributes(
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
...<4 lines>...
)
^
File "/opt/homeassistant/.homeassistant/custom_components/zha_toolkit/utils.py", line 1211, in cluster_read_attributes
return await cluster.read_attributes(attrs, manufacturer=manufacturer)
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
File "/opt/homeassistant/venv-3.13/lib/python3.13/site-packages/zigpy/zcl/__init__.py", line 965, in read_attributes
attr_def = self.find_attribute(attribute, manufacturer_code=manufacturer)
File "/opt/homeassistant/venv-3.13/lib/python3.13/site-packages/zigpy/zcl/__init__.py", line 513, in find_attribute
raise KeyError(manufacturer_code)
KeyError: 0
Custom quirk
Custom quirk
"""Quirk for ZLinky_TIC."""
from copy import deepcopy
from typing import Final
from zigpy.profiles import zgp, zha
from zigpy.quirks import CustomCluster, CustomDevice
import zigpy.types as t
from zigpy.zcl.clusters.general import (
Basic,
GreenPowerProxy,
Identify,
Ota,
PowerConfiguration,
Time,
)
from zigpy.zcl.clusters.homeautomation import ElectricalMeasurement, MeterIdentification
from zigpy.zcl.clusters.smartenergy import Metering
from zigpy.zcl.foundation import BaseAttributeDefs, ZCLAttributeDef
from zhaquirks.const import (
DEVICE_TYPE,
ENDPOINTS,
INPUT_CLUSTERS,
MODELS_INFO,
OUTPUT_CLUSTERS,
PROFILE_ID,
)
#AAU#from zhaquirks.lixee import LIXEE, ZLINKY_MANUFACTURER_CLUSTER_ID
import logging
_LOGGER = logging.getLogger(__name__)
LIXEE = "LiXee"
ZLINKY_MANUFACTURER_CLUSTER_ID = 0xFF66
from zigpy.quirks import DEVICE_REGISTRY
# other existing imports from custom quirk
# remove upstream quirk from registry
try:
#_LOGGER.error("Registry:\n %s", ',\n '.join(str(DEVICE_REGISTRY._registry_v1).split(',')))
for model_registry in DEVICE_REGISTRY._registry_v1.values():
#_LOGGER.error("model_registry:\n %s", ',\n '.join(str(model_registry).split(',')))
#for key, value in model_registry.items():
# _LOGGER.error("model_registry.name: %s", key)
# _LOGGER.error("model_registry.value:\n %s", ',\n '.join(str(value).split(',')))
if 'ZLinky_TIC' in model_registry:
del model_registry['ZLinky_TIC']
_LOGGER.error("'ZLinky_TIC' removed.")
except Exception as e:
_LOGGER.error("Exception: %s", str(e))
try:
del DEVICE_REGISTRY._registry_v2[(LIXEE, "ZLinky_TIC")]
except Exception as e:
_LOGGER.warning("Exception: %s", str(e))
#AAU#
from zhaquirks.tuya import TuyaManufCluster
class ZLinkyTICManufacturerCluster(CustomCluster):
"""ZLinkyTICManufacturerCluster manufacturer cluster."""
cluster_id = ZLINKY_MANUFACTURER_CLUSTER_ID
name = "ZLinky_TIC Manufacturer specific"
ep_attribute = "zlinky_manufacturer_specific"
# The attribute comments below are in French to match the reference documentation,
# see https://github.com/fairecasoimeme/Zlinky_TIC/tree/v9.0#synth%C3%A8se-d%C3%A9veloppeur
# and https://github.com/fairecasoimeme/Zlinky_TIC/blob/v9.0/ZLinky/Source/LixeeCluster.h
class AttributeDefs(BaseAttributeDefs):
"""Attribute definitions."""
# Historical mode: OPTARIF "Option tarifaire" / String 4 car
# Standard mode: NGTF "Nom du calendrier tarifaire fournisseur" / String 16 car
hist_tariff_option_or_std_supplier_price_schedule_name: Final = ZCLAttributeDef(
id=0x0000, type=t.LimitedCharString(16), is_manufacturer_specific=True
)
# Historical mode: DEMAIN "Couleur du lendemain" / String 4 car
hist_tomorrow_color: Final = ZCLAttributeDef(
id=0x0001, type=t.LimitedCharString(4), is_manufacturer_specific=True
)
# Historical mode: HHPHC "Horaire Heure Pleines Heures Creuses" / Uint8 1 car
hist_schedule_peak_hours_off_peak_hours: Final = ZCLAttributeDef(
id=0x0002, type=t.uint8_t, is_manufacturer_specific=True
)
# Historical mode: PPOT "Présence des potentiels" (Triphasé) / Uint8 2 car
hist_potentials_presence: Final = ZCLAttributeDef(
id=0x0003, type=t.uint8_t, is_manufacturer_specific=True
)
# Historical mode: PEJP "Préavis début EJP(30min)" / Uint8 2 car
hist_ejp_start_notice: Final = ZCLAttributeDef(
id=0x0004, type=t.uint8_t, is_manufacturer_specific=True
)
# Historical mode: ADPS "Avertissement de Dépassement De Puissance Souscrite" / Uint16 3 car
hist_subscribed_power_exceeding_warning: Final = ZCLAttributeDef(
id=0x0005, type=t.uint16_t, is_manufacturer_specific=True
)
# Historical mode: ADIR1 "Avertissement de Dépassement D'intensité phase 1" / Uint16 3 car
hist_current_exceeding_warning_phase_1: Final = ZCLAttributeDef(
id=0x0006, type=t.uint16_t, is_manufacturer_specific=True
)
# Historical mode: ADIR2 "Avertissement de Dépassement D'intensité phase 2" / Uint16 3 car
hist_current_exceeding_warning_phase_2: Final = ZCLAttributeDef(
id=0x0007, type=t.uint16_t, is_manufacturer_specific=True
)
# Historical mode: ADIR3 "Avertissement de Dépassement D'intensité phase 3" / Uint16 3 car
hist_current_exceeding_warning_phase_3: Final = ZCLAttributeDef(
id=0x0008, type=t.uint16_t, is_manufacturer_specific=True
)
# Historical mode: MOTDETAT "Etat du Linky (From V13)" / String 6 car
linky_status: Final = ZCLAttributeDef(
id=0x0009, type=t.LimitedCharString(6), is_manufacturer_specific=True
)
# Historical and standard mode: "Tariff Period (From V15)" / String 16 car
linky_tariff_period: Final = ZCLAttributeDef(
id=0x0010, type=t.LimitedCharString(16), is_manufacturer_specific=True
)
# Historical and Standard mode: "Linky acquisition time (From V7)"" / Uint8 1 car
linky_acquisition_time: Final = ZCLAttributeDef(
id=0x0100, type=t.uint8_t, is_manufacturer_specific=True
)
# Standard mode: LTARF "Libellé tarif fournisseur en cours" / String 16 car
std_current_supplier_price_description: Final = ZCLAttributeDef(
id=0x0200, type=t.LimitedCharString(16), is_manufacturer_specific=True
)
# Standard mode: NTARF "Numéro de l'index tarifaire en cours" / Uint8 2 car
std_current_tariff_index_number: Final = ZCLAttributeDef(
id=0x0201, type=t.uint8_t, is_manufacturer_specific=True
)
# Standard mode: DATE "Date et heure courant" / String 10 car
std_current_date_and_time: Final = ZCLAttributeDef(
id=0x0202, type=t.LimitedCharString(10), is_manufacturer_specific=True
)
# Standard mode: EASD01 "Energie active soutirée Distributeur, index 01" / Uint32 9 car
std_active_energy_withdrawn_distributor_index_01: Final = ZCLAttributeDef(
id=0x0203, type=t.uint32_t, is_manufacturer_specific=True
)
# Standard mode: EASD02 "Energie active soutirée Distributeur, index 02" / Uint32 9 car
std_active_energy_withdrawn_distributor_index_02: Final = ZCLAttributeDef(
id=0x0204, type=t.uint32_t, is_manufacturer_specific=True
)
# Standard mode: EASD03 "Energie active soutirée Distributeur, index 03" / Uint32 9 car
std_active_energy_withdrawn_distributor_index_03: Final = ZCLAttributeDef(
id=0x0205, type=t.uint32_t, is_manufacturer_specific=True
)
# Standard mode: EASD04 "Energie active soutirée Distributeur, index 04" / Uint32 9 car
std_active_energy_withdrawn_distributor_index_04: Final = ZCLAttributeDef(
id=0x0206, type=t.uint32_t, is_manufacturer_specific=True
)
# Standard mode: SINSTI "Puissance app. Instantanée injectée" (Production) / Uint16 5 car
std_apparent_power_injected_instantaneous: Final = ZCLAttributeDef(
id=0x0207, type=t.uint16_t, is_manufacturer_specific=True
)
# Standard mode: SMAXIN "Puissance app max. injectée n" (Production) / Uint16 5 car
std_apparent_power_injected_max: Final = ZCLAttributeDef(
id=0x0208, type=t.uint16_t, is_manufacturer_specific=True
)
# Standard mode: SMAXIN-1 "Puissance app max. injectée n-1" (Production) / Uint16 5 car
std_apparent_power_injected_max_1: Final = ZCLAttributeDef(
id=0x0209, type=t.uint16_t, is_manufacturer_specific=True
)
# Standard mode: CCAIN "Point n de la courbe de charge active injectée" (Production) / Uint16 5 car
std_injected_active_load_curve_point_n: Final = ZCLAttributeDef(
id=0x0210, type=t.uint16_t, is_manufacturer_specific=True
)
# Standard mode: CCAIN-1 "Point n-1 de la courbe de charge active injectée" (Production) / Uint16 5 car
std_injected_active_load_curve_point_n_1: Final = ZCLAttributeDef(
id=0x0211, type=t.uint16_t, is_manufacturer_specific=True
)
# Standard mode: SMAXN-1 "Puissance app. max. soutirée n-1" (Monophasé) / Uint16 5 car
# Standard mode: SMAXN1-1 "Puissance app. max. soutirée n-1 ph.1" (Triphasé) / Uint16 5 car
std_apparent_power_withdrawn_max_phase_1_n_1: Final = ZCLAttributeDef(
id=0x0212, type=t.uint16_t, is_manufacturer_specific=True
)
# Standard mode: SMAXN2-1 "Puissance app. max. soutirée n-1 ph. 2" (Triphasé) / Uint16 5 car
std_apparent_power_withdrawn_max_phase_2_n_1: Final = ZCLAttributeDef(
id=0x0213, type=t.uint16_t, is_manufacturer_specific=True
)
# Standard mode: SMAXN3-1 "Puissance app. max. soutirée n-1 ph. 3" (Triphasé) / Uint16 5 car
std_apparent_power_withdrawn_max_phase_3_n_1: Final = ZCLAttributeDef(
id=0x0214, type=t.uint16_t, is_manufacturer_specific=True
)
# Standard mode: MSG1 "Message court" / String 32 car
std_message_short: Final = ZCLAttributeDef(
id=0x0215, type=t.LimitedCharString(32), is_manufacturer_specific=True
)
# Standard mode: MSG2 "Message ultra court" / String 16 car
std_message_ultra_short: Final = ZCLAttributeDef(
id=0x0216, type=t.LimitedCharString(16), is_manufacturer_specific=True
)
# Standard mode: STGE "Registre de Statuts" / String 8 car /* codespell:ignore */
std_status_register: Final = ZCLAttributeDef(
id=0x0217, type=t.LimitedCharString(8), is_manufacturer_specific=True
)
# Standard mode: DPM1 "Début Pointe Mobile 1" / Uint8 2 car
std_mobile_peak_start_1: Final = ZCLAttributeDef(
id=0x0218, type=t.uint8_t, is_manufacturer_specific=True
)
# Standard mode: FPM1 "Fin Pointe Mobile 1" / Uint8 2 car
std_mobile_peak_end_1: Final = ZCLAttributeDef(
id=0x0219, type=t.uint8_t, is_manufacturer_specific=True
)
# Standard mode: DPM2 "Début Pointe Mobile 2" / Uint8 2 car
std_mobile_peak_start_2: Final = ZCLAttributeDef(
id=0x0220, type=t.uint8_t, is_manufacturer_specific=True
)
# Standard mode: FPM2 "Fin Pointe Mobile 2" / Uint8 2 car
std_mobile_peak_end_2: Final = ZCLAttributeDef(
id=0x0221, type=t.uint8_t, is_manufacturer_specific=True
)
# Standard mode: DPM3 "Début Pointe Mobile 3" / Uint8 2 car
std_mobile_peak_start_3: Final = ZCLAttributeDef(
id=0x0222, type=t.uint8_t, is_manufacturer_specific=True
)
# Standard mode: FPM3 "Fin Pointe Mobile 3" / Uint8 2 car
std_mobile_peak_end_3: Final = ZCLAttributeDef(
id=0x0223, type=t.uint8_t, is_manufacturer_specific=True
)
# Standard mode: RELAIS "RELAIS" / Uint16 3 car
std_relay: Final = ZCLAttributeDef(
id=0x0224, type=t.uint8_t, is_manufacturer_specific=True
)
# Standard mode: NJOURF "Numéro du jour en cours calendrier fournisseur" / Uint8 2 car
std_supplier_calendar_current_day_number: Final = ZCLAttributeDef(
id=0x0225, type=t.uint8_t, is_manufacturer_specific=True
)
# Standard mode: NJOURF+1 "Numéro du prochain jour calendrier fournisseur" / Uint8 2 car
std_supplier_calendar_next_day_number: Final = ZCLAttributeDef(
id=0x0226, type=t.uint8_t, is_manufacturer_specific=True
)
# Standard mode: PJOURF+1 "Profil du prochain jour calendrier fournisseur" / String 98 car
std_supplier_calendar_next_day_profile: Final = ZCLAttributeDef(
id=0x0227, type=t.LimitedCharString(98), is_manufacturer_specific=True
)
# Standard mode: PPOINTE1 "Profil du prochain jour de pointe" / String 98 car
std_next_peak_day_profile: Final = ZCLAttributeDef(
id=0x0228, type=t.LimitedCharString(98), is_manufacturer_specific=True
)
# Historical and Standard mode: - "Linky Mode (From V4)" / Uint8 1 car
linky_mode: Final = ZCLAttributeDef(
id=0x0300, type=t.uint8_t, is_manufacturer_specific=True
)
class ZLinkyTICMetering(CustomCluster, Metering):
"""ZLinky_TIC custom metring cluster."""
# ZLinky_TIC reports current_summ_delivered in Wh
# Home Assistant expects kWh (1kWh = 1000 Wh)
MULTIPLIER = 0x0301
DIVISOR = 0x0302
_CONSTANT_ATTRIBUTES = {MULTIPLIER: 1, DIVISOR: 1000}
# The attribute comments below are in French to match the reference documentation,
# see https://github.com/fairecasoimeme/Zlinky_TIC/tree/v9.0#synth%C3%A8se-d%C3%A9veloppeur
# and https://github.com/fairecasoimeme/Zlinky_TIC/blob/v9.0/ZLinky/Source/LixeeCluster.h
class AttributeDefs(Metering.AttributeDefs):
"""Attribute additions."""
# Standard mode: EAIT "Energie active injectée totale" (Production) / Int48 9 car
std_total_injected_active_energy: Final = ZCLAttributeDef(
id=0x0001, type=t.uint48_t, is_manufacturer_specific=True
)
# Standard mode: PTEC "Période tarifaire en cours" / String 4 car
hist_current_tarif_period: Final = ZCLAttributeDef(
id=0x0020, type=t.LimitedCharString(4), is_manufacturer_specific=True
)
class ZLinkyTIC(CustomDevice):
"""ZLinky_TIC from LiXee."""
signature = {
MODELS_INFO: [(LIXEE, "ZLinky_TIC")],
ENDPOINTS: {
1: {
PROFILE_ID: zha.PROFILE_ID,
DEVICE_TYPE: zha.DeviceType.METER_INTERFACE,
INPUT_CLUSTERS: [
Basic.cluster_id,
Identify.cluster_id,
Metering.cluster_id,
MeterIdentification.cluster_id,
ElectricalMeasurement.cluster_id,
ZLinkyTICManufacturerCluster.cluster_id,
],
OUTPUT_CLUSTERS: [Ota.cluster_id],
},
242: {
PROFILE_ID: zgp.PROFILE_ID,
DEVICE_TYPE: zgp.DeviceType.PROXY_BASIC,
INPUT_CLUSTERS: [GreenPowerProxy.cluster_id],
OUTPUT_CLUSTERS: [GreenPowerProxy.cluster_id],
},
},
}
replacement = {
ENDPOINTS: {
1: {
PROFILE_ID: zha.PROFILE_ID,
DEVICE_TYPE: zha.DeviceType.METER_INTERFACE,
INPUT_CLUSTERS: [
Basic.cluster_id,
PowerConfiguration.cluster_id,
Identify.cluster_id,
ZLinkyTICMetering,
MeterIdentification.cluster_id,
ElectricalMeasurement.cluster_id,
ZLinkyTICManufacturerCluster,
],
OUTPUT_CLUSTERS: [Ota.cluster_id],
},
242: {
PROFILE_ID: zgp.PROFILE_ID,
DEVICE_TYPE: zgp.DeviceType.PROXY_BASIC,
INPUT_CLUSTERS: [GreenPowerProxy.cluster_id],
OUTPUT_CLUSTERS: [GreenPowerProxy.cluster_id],
},
},
}
class ZLinkyTICFWV12(ZLinkyTIC):
"""ZLinky_TIC from LiXee with firmware v12.0 & v13.0."""
signature = deepcopy(ZLinkyTIC.signature)
# Insert PowerConfiguration cluster in signature for devices with firmware v12.0 & v13.0
signature[ENDPOINTS][1][INPUT_CLUSTERS].insert(1, PowerConfiguration.cluster_id)
class ZLinkyTICFWV14(ZLinkyTICFWV12):
"""ZLinky_TIC from LiXee with firmware v14.0+."""
signature = deepcopy(ZLinkyTICFWV12.signature)
replacement = deepcopy(ZLinkyTICFWV12.replacement)
# Insert Time configuration cluster in signature for devices with firmware v14.0+
signature[ENDPOINTS][1][INPUT_CLUSTERS].insert(1, Time.cluster_id)
# Insert Tuya cluster in signature for devices with firmware v14.0+
signature[ENDPOINTS][1][INPUT_CLUSTERS].insert(7, TuyaManufCluster.cluster_id)
signature[ENDPOINTS][1][OUTPUT_CLUSTERS].insert(1, TuyaManufCluster.cluster_id)
replacement[ENDPOINTS][1][INPUT_CLUSTERS].insert(1, Time.cluster_id)
class ZLinkyTICFWV15(ZLinkyTICFWV14):
"""ZLinky_TIC from LiXee with firmware v15.0+."""
signature = deepcopy(ZLinkyTICFWV14.signature)
replacement = deepcopy(ZLinkyTICFWV14.replacement)
signature[ENDPOINTS][1][DEVICE_TYPE] = zha.DeviceType.DIMMABLE_LIGHT
replacement[ENDPOINTS][1][DEVICE_TYPE] = zha.DeviceType.DIMMABLE_LIGHTAdditional information
FWIW, I've provided the custom_quirk that solves my issue.
Obliously, it's only the addition of AttributeDefs in the ZLinkyTICMetering that is relevant.