Control Objective

Healthcare AI agents must undergo comprehensive risk assessment and continuous lifecycle management that aligns with FDA Total Product Lifecycle approach, EU AI Act high-risk classification, and Health Canada SGBA+ requirements. This ensures that AI agents maintain safety, effectiveness, and regulatory compliance throughout their operational lifespan while adapting to evolving clinical environments and patient populations.


C1.1 Healthcare Risk Classification & Assessment

Implement three-factor risk assessment (clinical function, autonomy level, data sensitivity) aligned with medical device regulatory frameworks and SaMD classification requirements.

# Description Level Role
1.1.1 Verify that all healthcare AI agents undergo mandatory three-factor risk assessment evaluating clinical function (diagnostic, therapeutic, monitoring, administrative), autonomy level (alert, decision support, autonomous action), and data sensitivity (PHI, genomic, behavioral health) before clinical deployment. 1 H/V
1.1.2 Verify that AI agents handling diagnostic or therapeutic functions are automatically classified as high-risk regardless of other factors, requiring enhanced verification and clinical oversight. 1 H/V
1.1.3 Verify that risk assessment outcomes map to established medical device classification frameworks (FDA Class I/II/III, EU MDR risk classes, Health Canada Class I-IV) and include SaMD (Software as Medical Device) risk categorization based on healthcare decision state and healthcare situation severity. 1 V
1.1.4 Verify that SaMD risk mapping explicitly categorizes agents across four risk levels: Class I (low risk - inform healthcare decisions for non-serious situations), Class II (moderate risk - drive/inform decisions for serious/critical situations), Class III (high risk - trigger/drive decisions for serious situations), and Class IV (highest risk - trigger decisions for critical situations). 1 V
1.1.5 Verify that patient population risk factors (pediatric, elderly, critical care, emergency medicine) are explicitly evaluated and documented in risk assessment outcomes with specific attention to vulnerable population protection requirements. 2 H/C
1.1.6 Verify that risk assessments include healthcare-specific threat modeling covering clinical workflow disruption, patient safety incidents, and medical data breach scenarios with SaMD-appropriate mitigation strategies. 2 H/V
1.1.7 Verify that risk classification decisions undergo clinical review by qualified healthcare professionals with AI competency and SaMD regulatory expertise. 3 C

C1.2 FDA 510(k) Predicate Device Analysis

Implement comprehensive predicate device analysis for AI agents seeking FDA 510(k) clearance pathway, ensuring substantial equivalence determination accuracy.

# Description Level Role
1.2.1 Verify that healthcare AI agents pursuing FDA 510(k) clearance undergo systematic predicate device identification including comprehensive FDA database search, clinical function mapping, and intended use analysis for substantially equivalent devices. 1 V
1.2.2 Verify that predicate device analysis includes detailed comparison of clinical indications, patient populations, operating conditions, technological characteristics, and performance specifications between the AI agent and selected predicate devices. 1 V
1.2.3 Verify that substantial equivalence analysis addresses AI-specific considerations including training data characteristics, algorithm performance, clinical validation requirements, and human factors engineering compared to predicate devices. 2 V
1.2.4 Verify that predicate device analysis includes risk-benefit evaluation demonstrating that AI agent differences from predicate devices do not raise new safety or effectiveness concerns requiring PMA pathway consideration. 2 V
1.2.5 Verify that 510(k) documentation includes comprehensive clinical performance comparison with predicate devices including sensitivity, specificity, positive/negative predictive values, and real-world performance validation data. 2 V
1.2.6 Verify that advanced predicate analysis includes assessment of AI agent tool usage capabilities and their impact on substantial equivalence determination, particularly for agents that integrate multiple healthcare tools or medical devices. 3 V

C1.3 FDA-Style Predetermined Change Control Plans (PCCP)

Implement change control plans that pre-specify allowable AI agent modifications without requiring new regulatory submissions.

# Description Level Role
1.3.1 Verify that all high-risk healthcare AI agents implement FDA-style Predetermined Change Control Plans (PCCP) specifying types of modifications, validation processes, and performance acceptance criteria before initial clinical deployment. 1 D/V
1.3.2 Verify that PCCP specifications include clinical performance metrics, patient safety monitoring parameters, and healthcare workflow integration requirements that must be maintained across agent updates. 1 H/D
1.3.3 Verify that all AI agent modifications are evaluated against PCCP criteria before implementation, with deviations requiring new risk assessment and potential regulatory submission. 2 D/V
1.3.4 Verify that PCCP implementation includes automated testing protocols that validate clinical safety, performance maintenance, and regulatory compliance for each agent modification. 2 D/V
1.3.5 Verify that PCCP documentation undergoes clinical review and regulatory affairs validation before submission to relevant healthcare authorities (FDA, EMA, Health Canada). 3 V
1.3.6 Verify that PCCP effectiveness is continuously monitored with metrics tracked for modification success rates, clinical performance stability, and regulatory compliance maintenance. 3 H/V

C1.4 Continuous Clinical Performance Monitoring

Implement real-time monitoring systems that detect performance degradation, model drift, and clinical safety issues.

# Description Level Role
1.4.1 Verify that healthcare AI agents implement continuous monitoring systems that track clinical performance metrics, patient safety indicators, and healthcare workflow integration effectiveness. 1 H/D
1.4.2 Verify that performance monitoring includes automated detection of model drift, accuracy degradation, and bias emergence across different patient populations and clinical scenarios. 1 D/V
1.4.3 Verify that monitoring systems maintain statistical significance testing and alert healthcare teams when performance degrades below clinically acceptable thresholds. 2 H/D
1.4.4 Verify that clinical performance data is continuously analyzed for Health Canada SGBA+ compliance, ensuring maintained performance across diverse patient demographics. 2 H/V
1.4.5 Verify that monitoring systems integrate with healthcare quality improvement processes and clinical incident reporting systems. 2 H/C
1.4.6 Verify that advanced monitoring includes predictive analytics that identify potential performance issues before they impact patient care. 3 D/V

C1.5 Regulatory Sandbox & Real-World Evidence

Leverage regulatory sandbox approaches for controlled testing and evidence generation in clinical environments.

# Description Level Role
1.5.1 Verify that healthcare AI agents undergo controlled testing in regulatory sandbox environments (UK MHRA AI Airlock, FDA Pre-Cert pilot) when available for the intended clinical use case. 2 H/V
1.5.2 Verify that real-world evidence collection protocols are established for healthcare AI agents, capturing clinical effectiveness, safety outcomes, and healthcare workflow impact data. 2 H/C
1.5.3 Verify that sandbox testing includes diverse patient populations and clinical scenarios representative of intended deployment environments. 2 H/C
1.5.4 Verify that evidence generation protocols align with regulatory authority requirements for post-market surveillance and clinical effectiveness demonstration. 3 V
1.5.5 Verify that sandbox results and real-world evidence are systematically integrated into continuous improvement processes and regulatory submissions. 3 H/V

C1.6 International Regulatory Harmonization

Ensure compliance with multiple international regulatory frameworks for global healthcare AI deployment.

# Description Level Role
1.6.1 Verify that healthcare AI agents meet harmonized requirements across major regulatory jurisdictions (FDA, EU AI Act, Health Canada, UK MHRA) for intended markets. 2 V
1.6.2 Verify that regulatory compliance documentation supports mutual recognition and reciprocity agreements between healthcare authorities. 3 V
1.6.3 Verify that AI agent design and validation processes incorporate IMDRF Good Machine Learning Practice (GMLP) principles for international harmonization. 3 D/V
1.6.4 Verify that compliance frameworks align with WHO GI-AI4H principles for global health equity and accessible healthcare AI deployment. 3 H/V

C1.7 Clinical Evidence & Tool Combination Validation

Establish clinical evidence generation requirements specific to AI agents using multiple healthcare tools, with evidence rigor scaled to risk levels and tool complexity.

# Description Level Role
1.7.1 Verify that healthcare AI agents undergo clinical evidence generation programs with evidence requirements scaled to risk classification: Class I agents require analytical validation, Class II require clinical validation studies, Class III/IV require randomized controlled trials. 1 V/C
1.7.2 Verify that clinical evidence specifically evaluates tool combination effectiveness including studies demonstrating that agent tool selection and usage patterns improve clinical outcomes compared to individual tool usage or standard of care. 1 V/C
1.7.3 Verify that tool combination validation includes safety studies assessing risks from agent-initiated tool interactions, cascading effects from tool usage sequences, and novel risk scenarios not present in individual tool usage. 1 V/C
1.7.4 Verify that clinical evidence generation includes diverse patient populations and clinical settings representative of intended deployment environments with specific attention to vulnerable populations and resource-constrained settings. 2 C
1.7.5 Verify that evidence requirements include real-world performance validation demonstrating maintained clinical effectiveness when agents operate across different healthcare systems, medical devices, and clinical workflows. 2 C
1.7.6 Verify that clinical validation includes human factors studies ensuring healthcare professionals can effectively supervise, override, and collaborate with tool-enabled agents in realistic clinical environments. 2 C/H
1.7.7 Verify that advanced evidence generation includes health economic studies demonstrating cost-effectiveness, workflow efficiency, and resource utilization benefits of tool-enabled agents compared to conventional healthcare delivery models. 3 C/V
1.7.8 Verify that long-term clinical studies evaluate agent performance evolution, tool usage pattern optimization, and clinical outcome sustainability over extended deployment periods with diverse patient cohorts. 3 C

C1.8 Clinical Risk Management Integration

Integrate AI agent risk management with existing healthcare risk management and patient safety systems.

# Description Level Role
1.8.1 Verify that AI agent risk management integrates with organizational healthcare risk management systems and clinical governance structures. 1 H
1.8.2 Verify that AI-related incidents are captured in healthcare incident reporting systems with appropriate root cause analysis and corrective action processes. 1 H/C
1.8.3 Verify that clinical risk management includes specific protocols for AI agent failure modes, backup procedures, and manual override capabilities. 2 H/C
1.8.4 Verify that risk management processes include patient safety officers and clinical leadership in AI agent oversight and incident response. 2 H/C
1.8.5 Verify that advanced risk management incorporates predictive risk analytics and proactive incident prevention for AI agent deployments. 3 H

Control Category C1 ensures that healthcare AI agents undergo comprehensive risk assessment and lifecycle management aligned with global regulatory requirements, maintaining clinical safety and regulatory compliance throughout their operational deployment.