2022-04-07 OXYGEN Datastream App v1.0.22 Installer.txt
DataStream Test Application for Oxygen, based on LabView Library (dewetron_lib_oxygen_datastream-1.0.22)

  • Files:
    ** OXYGEN Datastream App v1.0.22 Installer.zip

  • Version: 1.0.22

  • Requirements:
    ** Windows 10 64-Bit
    ** OXYGEN DataStream Plugin v1.6 or higher (OXYGEN R.5. or higher)

  • Installation procedure for OXYGEN Datastream App v1.0.22:
    ** Run installer by executing Setup.exe and follow instructions
    ** First installation will require some time as LAbVIEW Runtime is installed

  • Description
    ** Establishing a SCPI connection between LabVIEW and OXYGEN
    ** Querying the Channel List (:CHANNEL:NAM?)
    ** Specifying and querying the transferred channels (:DST:ITEMS; :DST:ITEMS?)
    ** Specifying and querying the data stream port (:DST:PORT xxxxx; :DST:PORT?)
    ** Intitalizing the data stream (:DST:INIT)
    ** Starting and stopping the data stream (:DST:START; :DST:STOP)
    ** Resetting the data stream (:DST:RES)
    ** Qerying the data stream state (:DST:STAT?)
    ** Decoding the following channel types:
    *** Synchronous channel with fixed sample size
    *** Synchronous channel with variable sample size
    *** Asynchronous channel with fixed sample size
    *** Asynchronous channel with variable sample size

  • Known Limitations
    ** Data rates tested: 6 ch á 100 kS/s; Higher data rates may need modifications in data decoder
    ** Digital channels (DIO, CNT) not support by DataStream interface