Skip to content

Conversation

@paulreimer
Copy link
Contributor

This builds a snip.apsta (and any of my custom apps) successfully with the new WICED 3.5.2 SDK. I'm a few KB over budget in my .text section, which had a few KB to spare with WICED 3.3.1, so it seems the libraries have grown in size a bit.

Also, I noticed that some of my apps are running a bit slower through the event loop.

Also, there is lots less to patch in this version, since SPI4 and SPI5 are (almost) fully supported (the IRQs were missing, but I retained that in the SPI patch).

@paulreimer
Copy link
Contributor Author

I just added the same patches that were needed for EMW3165, into the EMW3162 platform patches. I don't have an EMW3162, so I can't test this myself.

@Novatec1
Copy link

Novatec1 commented Jun 9, 2016

I am using this patch for emw3165+wiced-3.5.2 setup.
While using SPI5 I am completely stuck for last 4-5 days.

  1. emw3165 has spi5_MOSI pin as 29 , while the patch is using 31
  2. basically everytime I am reading some register from slave device I get same result which corresponds to 0x00 register, so MISO/ clock/ CS are all working fine, but MOSI of spi5 is not working
    any suggestion will be a great help. Our manufacturing divison already made 50 pieces of emw3165 based boards with MOSI at 29 following official documentation.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.