Skip to content
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
2 changes: 2 additions & 0 deletions docs/release_notes.rst
Original file line number Diff line number Diff line change
Expand Up @@ -24,6 +24,8 @@ Upcoming Release

* Align `snakemake` version and the related `mock_snakemake` to PyPSA-Eur (https://github.com/PyPSA/technology-data/pull/177)

* Improve assumptions for iron-air batteries (https://github.com/PyPSA/technology-data/pull/179)

* Improve filename consistency in the sources (https://github.com/PyPSA/technology-data/pull/178)

* Include further unit tests for compile_cost_assumptions_usa.py (https://github.com/PyPSA/technology-data/pull/182)
Expand Down
6 changes: 5 additions & 1 deletion inputs/US/manual_input_usa.csv
Original file line number Diff line number Diff line change
Expand Up @@ -127,4 +127,8 @@ Solid biomass steam reforming,FOM,2020,0.05,%/year,2010,"JRC, 01_JRC-EU-TIMES Fu
Natural gas steam reforming CC,FOM,2030,0.05,%/year,2010,"JRC, 01_JRC-EU-TIMES Full model ",
Natural gas steam reforming CC,FOM,2050,0.05,%/year,2010,"JRC, 01_JRC-EU-TIMES Full model ",
Coal gasification CC,FOM,2030,0.07,%/year,2010,"JRC, 01_JRC-EU-TIMES Full model ",
Biomass gasification CC,FOM,2030,0.02,%/year,2010,"JRC, 01_JRC-EU-TIMES Full model ",
Biomass gasification CC,FOM,2030,0.02,%/year,2010,"JRC, 01_JRC-EU-TIMES Full model ",
iron-air battery,investment,2025,28.62,EUR/kWh,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery,investment,2030,19.05,EUR/kWh,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery,investment,2035,14.40,EUR/kWh,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery,investment,2040,12.69,EUR/kWh,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
34 changes: 17 additions & 17 deletions inputs/manual_input.csv
Original file line number Diff line number Diff line change
Expand Up @@ -387,20 +387,20 @@ allam,investment,2030,1500,EUR/kW,2020,Own assumption. TODO: Find better technol
allam,VOM,2030,2,EUR/MWh,2020,Own assumption. TODO: Find better technology data and cost assumptions,
allam,efficiency,2030,0.6,p.u.,2020,Own assumption. TODO: Find better technology data and cost assumptions,
allam,lifetime,2030,30,years,2020,Own assumption. TODO: Find better technology data and cost assumptions,
iron-air battery,FOM,2025,1.02185373078457,%/year,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery,FOM,2030,1,%/year,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery,FOM,2035,1.10628646943421,%/year,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery,FOM,2040,1.1807773334732,%/year,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery,investment,2025,23.45,EUR/kWh,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery,investment,2030,15.61,EUR/kWh,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery,investment,2035,11.79,EUR/kWh,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery,investment,2040,10.4,EUR/kWh,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery charge,efficiency,2025,0.7,per unit,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery charge,efficiency,2030,0.71,per unit,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery charge,efficiency,2035,0.73,per unit,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery charge,efficiency,2040,0.74,per unit,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery discharge,efficiency,2025,0.59,per unit,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery discharge,efficiency,2030,0.6,per unit,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery discharge,efficiency,2035,0.62,per unit,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery discharge,efficiency,2040,0.63,per unit,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery,lifetime,2030,17.5,years,2020,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery,FOM,2025,1.02185373078457,%/year,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery,FOM,2030,1,%/year,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery,FOM,2035,1.10628646943421,%/year,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery,FOM,2040,1.1807773334732,%/year,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery,investment,2025,30.05,EUR/kWh,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery,investment,2030,20.00,EUR/kWh,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery,investment,2035,15.11,EUR/kWh,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery,investment,2040,13.33,EUR/kWh,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery charge,efficiency,2025,0.70,per unit,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery charge,efficiency,2030,0.71,per unit,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery charge,efficiency,2035,0.73,per unit,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery charge,efficiency,2040,0.74,per unit,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery discharge,efficiency,2025,0.59,per unit,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery discharge,efficiency,2030,0.60,per unit,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery discharge,efficiency,2035,0.62,per unit,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery discharge,efficiency,2040,0.63,per unit,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
iron-air battery,lifetime,2030,17.5,years,2023,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",
10 changes: 5 additions & 5 deletions outputs/US/costs_2020.csv
Original file line number Diff line number Diff line change
Expand Up @@ -3948,11 +3948,11 @@ industrial heat pump medium temperature,efficiency,2.55,per unit,"Danish Energy
industrial heat pump medium temperature,investment,877.2984,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Nominal investment,2019.0,,
industrial heat pump medium temperature,lifetime,20.0,years,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Technical lifetime,2019.0,,
iron ore DRI-ready,commodity,97.73,EUR/t,"Model assumptions from MPP Steel Transition Tool: https://missionpossiblepartnership.org/action-sectors/steel/, accessed: 2022-12-03.","DRI ready assumes 65% iron content, requiring no additional benefication.",2020.0,,
iron-air battery,FOM,1.0219,%/year,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,,
iron-air battery,investment,23.45,EUR/kWh,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,,
iron-air battery,lifetime,17.5,years,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,,
iron-air battery charge,efficiency,0.7,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,,
iron-air battery discharge,efficiency,0.59,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,,
iron-air battery,FOM,1.0219,%/year,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,,
iron-air battery,investment,23.9381,EUR/kWh,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,,
iron-air battery,lifetime,17.5,years,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,,
iron-air battery charge,efficiency,0.7,per unit,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,,
iron-air battery discharge,efficiency,0.59,per unit,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,,
lignite,CO2 intensity,0.4069,tCO2/MWh_th,Entwicklung der spezifischen Kohlendioxid-Emissionen des deutschen Strommix in den Jahren 1990 - 2018,,,,
lignite,FOM,1.31,%/year,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (39.5+91.25) USD/kW_e/a /2 / (1.09 USD/EUR) / investment cost * 100. Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0,,
lignite,VOM,3.2612,EUR/MWh_e,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (3+5.5)USD/MWh_e/2 / (1.09 USD/EUR). Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0,,
Expand Down
10 changes: 5 additions & 5 deletions outputs/US/costs_2025.csv
Original file line number Diff line number Diff line change
Expand Up @@ -4034,11 +4034,11 @@ industrial heat pump medium temperature,efficiency,2.625,per unit,"Danish Energy
industrial heat pump medium temperature,investment,830.775,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Nominal investment,2019.0,,
industrial heat pump medium temperature,lifetime,20.0,years,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Technical lifetime,2019.0,,
iron ore DRI-ready,commodity,97.73,EUR/t,"Model assumptions from MPP Steel Transition Tool: https://missionpossiblepartnership.org/action-sectors/steel/, accessed: 2022-12-03.","DRI ready assumes 65% iron content, requiring no additional benefication.",2020.0,,
iron-air battery,FOM,1.0219,%/year,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,,
iron-air battery,investment,23.45,EUR/kWh,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,,
iron-air battery,lifetime,17.5,years,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,,
iron-air battery charge,efficiency,0.7,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,,
iron-air battery discharge,efficiency,0.59,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,,
iron-air battery,FOM,1.0219,%/year,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,,
iron-air battery,investment,23.9381,EUR/kWh,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,,
iron-air battery,lifetime,17.5,years,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,,
iron-air battery charge,efficiency,0.7,per unit,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,,
iron-air battery discharge,efficiency,0.59,per unit,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,,
lignite,CO2 intensity,0.4069,tCO2/MWh_th,Entwicklung der spezifischen Kohlendioxid-Emissionen des deutschen Strommix in den Jahren 1990 - 2018,,,,
lignite,FOM,1.31,%/year,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (39.5+91.25) USD/kW_e/a /2 / (1.09 USD/EUR) / investment cost * 100. Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0,,
lignite,VOM,3.2612,EUR/MWh_e,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (3+5.5)USD/MWh_e/2 / (1.09 USD/EUR). Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0,,
Expand Down
10 changes: 5 additions & 5 deletions outputs/US/costs_2030.csv
Original file line number Diff line number Diff line change
Expand Up @@ -4190,11 +4190,11 @@ industrial heat pump medium temperature,efficiency,2.7,per unit,"Danish Energy A
industrial heat pump medium temperature,investment,784.2516,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Nominal investment,2019.0,,
industrial heat pump medium temperature,lifetime,20.0,years,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",302.a High temp. hp Up to 125 C: Technical lifetime,2019.0,,
iron ore DRI-ready,commodity,97.73,EUR/t,"Model assumptions from MPP Steel Transition Tool: https://missionpossiblepartnership.org/action-sectors/steel/, accessed: 2022-12-03.","DRI ready assumes 65% iron content, requiring no additional benefication.",2020.0,,
iron-air battery,FOM,1.0,%/year,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,,
iron-air battery,investment,15.61,EUR/kWh,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,,
iron-air battery,lifetime,17.5,years,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,,
iron-air battery charge,efficiency,0.71,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,,
iron-air battery discharge,efficiency,0.6,per unit,"Form Energy, FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2020.0,,
iron-air battery,FOM,1.0,%/year,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,,
iron-air battery,investment,15.9337,EUR/kWh,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,,
iron-air battery,lifetime,17.5,years,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,,
iron-air battery charge,efficiency,0.71,per unit,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,,
iron-air battery discharge,efficiency,0.6,per unit,"Form Energy, docu/FormEnergy_Europe_modeling_recommendations_2023.03.pdf, p4",,2023.0,,
lignite,CO2 intensity,0.4069,tCO2/MWh_th,Entwicklung der spezifischen Kohlendioxid-Emissionen des deutschen Strommix in den Jahren 1990 - 2018,,,,
lignite,FOM,1.31,%/year,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (39.5+91.25) USD/kW_e/a /2 / (1.09 USD/EUR) / investment cost * 100. Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0,,
lignite,VOM,3.2612,EUR/MWh_e,"Lazard's levelized cost of energy analysis - version 16.0 (2023): https://www.lazard.com/media/typdgxmm/lazards-lcoeplus-april-2023.pdf , pg. 49 (Levelized Cost of Energy - Key Assumptions), accessed: 2023-12-14.","Calculated based on average of listed range, i.e. (3+5.5)USD/MWh_e/2 / (1.09 USD/EUR). Note: Assume same costs as for hard coal, as cost structure is apparently comparable, see https://diglib.tugraz.at/download.php?id=6093e88b63f93&location=browse and https://iea.blob.core.windows.net/assets/ae17da3d-e8a5-4163-a3ec-2e6fb0b5677d/Projected-Costs-of-Generating-Electricity-2020.pdf . ",2023.0,,
Expand Down
Loading