4 changes: 3 additions & 1 deletion docs/release_notes.rst
Original file line number Diff line number Diff line change
Expand Up @@ -11,7 +11,9 @@ Release Notes
Upcoming Release
================

* Removed water-sourced heat pumps, as cost assumptions (based on higher uncertainty range in DEA tables) are a) likely overestimates and b) break pessimistic/optimistic scenarios. Reccomendation: Use excess-heat-sourced heat pump data or see DEA data on seawater-sourced heat pumps.
* Removed geothermal-sourced heat pumps and fixed previously underestimated costs for geothermal heat source. Recommendation: Use excess-heat-sourced heat pump data for geothermal-sourced heat pumps (only the heat pump part of the costs!) and consult the DEA technology catalogue.

* Removed water-sourced heat pumps, as cost assumptions (based on higher uncertainty range in DEA tables) are a) likely overestimates and b) break pessimistic/optimistic scenarios. Recomendation: Use excess-heat-sourced heat pump data or see DEA data on seawater-sourced heat pumps.

.. .. warning::

Expand Down
12 changes: 4 additions & 8 deletions outputs/US/costs_2020.csv
Original file line number Diff line number Diff line change
Expand Up @@ -3613,14 +3613,10 @@ central gas boiler,VOM,1.164,EUR/MWh_th,"Danish Energy Agency, inputs/technology
central gas boiler,efficiency,1.03,per unit,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","44 Natural Gas DH Only: Total efficiency , net, annual average",2015.0,,
central gas boiler,investment,63.4933,EUR/kW_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Nominal investment,2015.0,,
central gas boiler,lifetime,25.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Technical lifetime,2015.0,,
central geothermal heat source,FOM,1.4715,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0,,
central geothermal heat source,VOM,6.0281,EUR/MWh,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0,,
central geothermal heat source,investment,1625.2908,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0,,
central geothermal heat source,lifetime,25.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0,,
central geothermal-sourced heat pump,FOM,3.3935,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0,,
central geothermal-sourced heat pump,VOM,6.0281,EUR/MWh_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0,,
central geothermal-sourced heat pump,investment,704.7435,EUR/kW_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0,,
central geothermal-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0,,
central geothermal heat source,FOM,0.8406,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Fixed O&M",2015.0,,
central geothermal heat source,VOM,4.8547,EUR/MWh,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Variable O&M",2015.0,,
central geothermal heat source,investment,3008.7285,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Nominal investment",2015.0,,
central geothermal heat source,lifetime,25.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Technical lifetime",2015.0,,
central ground-sourced heat pump,FOM,0.3546,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Fixed O&M",2015.0,,
central ground-sourced heat pump,VOM,1.0392,EUR/MWh_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Variable O&M",2015.0,,
central ground-sourced heat pump,efficiency,1.71,per unit,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Total efficiency , net, annual average",2015.0,,
Expand Down
12 changes: 4 additions & 8 deletions outputs/US/costs_2025.csv
Original file line number Diff line number Diff line change
Expand Up @@ -3693,14 +3693,10 @@ central gas boiler,VOM,1.1111,EUR/MWh_th,"Danish Energy Agency, inputs/technolog
central gas boiler,efficiency,1.035,per unit,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","44 Natural Gas DH Only: Total efficiency , net, annual average",2015.0,,
central gas boiler,investment,58.2022,EUR/kW_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Nominal investment,2015.0,,
central gas boiler,lifetime,25.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Technical lifetime,2015.0,,
central geothermal heat source,FOM,1.4691,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0,,
central geothermal heat source,VOM,6.0453,EUR/MWh,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0,,
central geothermal heat source,investment,1577.4881,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0,,
central geothermal heat source,lifetime,25.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0,,
central geothermal-sourced heat pump,FOM,3.2884,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0,,
central geothermal-sourced heat pump,VOM,6.0453,EUR/MWh_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0,,
central geothermal-sourced heat pump,investment,704.7435,EUR/kW_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0,,
central geothermal-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0,,
central geothermal heat source,FOM,0.8422,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Fixed O&M",2015.0,,
central geothermal heat source,VOM,4.7812,EUR/MWh,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Variable O&M",2015.0,,
central geothermal heat source,investment,2915.219,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Nominal investment",2015.0,,
central geothermal heat source,lifetime,25.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Technical lifetime",2015.0,,
central ground-sourced heat pump,FOM,0.3733,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Fixed O&M",2015.0,,
central ground-sourced heat pump,VOM,1.183,EUR/MWh_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Variable O&M",2015.0,,
central ground-sourced heat pump,efficiency,1.72,per unit,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Total efficiency , net, annual average",2015.0,,
Expand Down
12 changes: 4 additions & 8 deletions outputs/US/costs_2030.csv
Original file line number Diff line number Diff line change
Expand Up @@ -3849,14 +3849,10 @@ central gas boiler,VOM,1.0582,EUR/MWh_th,"Danish Energy Agency, inputs/technolog
central gas boiler,efficiency,1.04,per unit,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","44 Natural Gas DH Only: Total efficiency , net, annual average",2015.0,,
central gas boiler,investment,52.9111,EUR/kW_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Nominal investment,2015.0,,
central gas boiler,lifetime,25.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Technical lifetime,2015.0,,
central geothermal heat source,FOM,1.4735,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0,,
central geothermal heat source,VOM,6.4843,EUR/MWh,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0,,
central geothermal heat source,investment,1529.6854,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0,,
central geothermal heat source,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0,,
central geothermal-sourced heat pump,FOM,3.7314,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0,,
central geothermal-sourced heat pump,VOM,6.4843,EUR/MWh_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0,,
central geothermal-sourced heat pump,investment,604.0659,EUR/kW_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0,,
central geothermal-sourced heat pump,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0,,
central geothermal heat source,FOM,0.8437,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Fixed O&M",2015.0,,
central geothermal heat source,VOM,4.86,EUR/MWh,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Variable O&M",2015.0,,
central geothermal heat source,investment,2822.2404,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Nominal investment",2015.0,,
central geothermal heat source,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Technical lifetime",2015.0,,
central ground-sourced heat pump,FOM,0.394,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Fixed O&M",2015.0,,
central ground-sourced heat pump,VOM,1.3268,EUR/MWh_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Variable O&M",2015.0,,
central ground-sourced heat pump,efficiency,1.73,per unit,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Total efficiency , net, annual average",2015.0,,
Expand Down
12 changes: 4 additions & 8 deletions outputs/US/costs_2035.csv
Original file line number Diff line number Diff line change
Expand Up @@ -3873,14 +3873,10 @@ central gas boiler,VOM,1.0582,EUR/MWh_th,"Danish Energy Agency, inputs/technolog
central gas boiler,efficiency,1.04,per unit,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","44 Natural Gas DH Only: Total efficiency , net, annual average",2015.0,,
central gas boiler,investment,52.9111,EUR/kW_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Nominal investment,2015.0,,
central gas boiler,lifetime,25.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Technical lifetime,2015.0,,
central geothermal heat source,FOM,1.4723,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0,,
central geothermal heat source,VOM,6.5503,EUR/MWh,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0,,
central geothermal heat source,investment,1505.7841,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0,,
central geothermal heat source,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0,,
central geothermal-sourced heat pump,FOM,3.6701,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0,,
central geothermal-sourced heat pump,VOM,6.5503,EUR/MWh_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0,,
central geothermal-sourced heat pump,investment,604.0659,EUR/kW_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0,,
central geothermal-sourced heat pump,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0,,
central geothermal heat source,FOM,0.845,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Fixed O&M",2015.0,,
central geothermal heat source,VOM,4.8424,EUR/MWh,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Variable O&M",2015.0,,
central geothermal heat source,investment,2773.9495,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Nominal investment",2015.0,,
central geothermal heat source,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Technical lifetime",2015.0,,
central ground-sourced heat pump,FOM,0.4041,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Fixed O&M",2015.0,,
central ground-sourced heat pump,VOM,1.373,EUR/MWh_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Variable O&M",2015.0,,
central ground-sourced heat pump,efficiency,1.735,per unit,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Total efficiency , net, annual average",2015.0,,
Expand Down
12 changes: 4 additions & 8 deletions outputs/US/costs_2040.csv
Original file line number Diff line number Diff line change
Expand Up @@ -3873,14 +3873,10 @@ central gas boiler,VOM,1.0582,EUR/MWh_th,"Danish Energy Agency, inputs/technolog
central gas boiler,efficiency,1.04,per unit,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","44 Natural Gas DH Only: Total efficiency , net, annual average",2015.0,,
central gas boiler,investment,52.9111,EUR/kW_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Nominal investment,2015.0,,
central gas boiler,lifetime,25.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Technical lifetime,2015.0,,
central geothermal heat source,FOM,1.4711,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0,,
central geothermal heat source,VOM,6.6163,EUR/MWh,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0,,
central geothermal heat source,investment,1481.8828,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0,,
central geothermal heat source,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0,,
central geothermal-sourced heat pump,FOM,3.6088,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0,,
central geothermal-sourced heat pump,VOM,6.6163,EUR/MWh_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0,,
central geothermal-sourced heat pump,investment,604.0659,EUR/kW_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0,,
central geothermal-sourced heat pump,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0,,
central geothermal heat source,FOM,0.8464,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Fixed O&M",2015.0,,
central geothermal heat source,VOM,4.8249,EUR/MWh,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Variable O&M",2015.0,,
central geothermal heat source,investment,2725.6586,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Nominal investment",2015.0,,
central geothermal heat source,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","45.1.b Geothermal DH, 2000m, E: Technical lifetime",2015.0,,
central ground-sourced heat pump,FOM,0.4147,%/year,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Fixed O&M",2015.0,,
central ground-sourced heat pump,VOM,1.4192,EUR/MWh_th,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Variable O&M",2015.0,,
central ground-sourced heat pump,efficiency,1.74,per unit,"Danish Energy Agency, inputs/technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Total efficiency , net, annual average",2015.0,,