3 changes: 3 additions & 0 deletions docs/release_notes.rst
Original file line number Diff line number Diff line change
Expand Up @@ -16,6 +16,9 @@ Upcoming Release
.. The features listed below are not released yet, but will be part of the next release!
.. To use the features already you have to use the ``master`` branch.

* Updated indexing of DEA Excel data for PTES and revised capital cost and FOM assumptions for 2045 and 2050.


* Corrected units for standing losses of TES technologies from per unit to %/hour and changed parameter names from "Energy losses during storage" to "standing losses" as well as "Temperature difference" to "temperature difference" for naming consistency.


Expand Down
4 changes: 2 additions & 2 deletions outputs/US/costs_2045.csv
Original file line number Diff line number Diff line change
Expand Up @@ -3981,10 +3981,10 @@ central solid biomass CHP powerboost CC,lifetime,25.0,years,"Danish Energy Agenc
central water pit charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0,,
central water pit discharger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2020.0,,
central water pit storage,Bottom storage temperature,35.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical bottom storage temperature,2020.0,,
central water pit storage,FOM,0.2544,%/year,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2020.0,,
central water pit storage,FOM,0.2652,%/year,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2020.0,,
central water pit storage,Top storage temperature,90.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical max. storage temperature,2020.0,,
central water pit storage,energy to power ratio,22.5,h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Ratio between energy storage and input capacity,2020.0,,
central water pit storage,investment,0.9826,EUR/kWh Capacity,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2020.0,,
central water pit storage,investment,0.9427,EUR/kWh Capacity,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2020.0,,
central water pit storage,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Technical lifetime,2020.0,,
central water pit storage,standing losses,0.0078,%/hour,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Energy losses during storage,2020.0,,
central water tank charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0,,
Expand Down
4 changes: 2 additions & 2 deletions outputs/US/costs_2050.csv
Original file line number Diff line number Diff line change
Expand Up @@ -3981,10 +3981,10 @@ central solid biomass CHP powerboost CC,lifetime,25.0,years,"Danish Energy Agenc
central water pit charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0,,
central water pit discharger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2020.0,,
central water pit storage,Bottom storage temperature,35.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical bottom storage temperature,2020.0,,
central water pit storage,FOM,0.2544,%/year,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2020.0,,
central water pit storage,FOM,0.2769,%/year,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2020.0,,
central water pit storage,Top storage temperature,90.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical max. storage temperature,2020.0,,
central water pit storage,energy to power ratio,22.5,h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Ratio between energy storage and input capacity,2020.0,,
central water pit storage,investment,0.9826,EUR/kWh Capacity,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2020.0,,
central water pit storage,investment,0.9029,EUR/kWh Capacity,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2020.0,,
central water pit storage,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Technical lifetime,2020.0,,
central water pit storage,standing losses,0.0078,%/hour,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Energy losses during storage,2020.0,,
central water tank charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0,,
Expand Down
4 changes: 2 additions & 2 deletions outputs/costs_2045.csv
Original file line number Diff line number Diff line change
Expand Up @@ -825,10 +825,10 @@ central solid biomass CHP powerboost CC,lifetime,25.0,years,"Danish Energy Agenc
central water pit charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0
central water pit discharger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2020.0
central water pit storage,Bottom storage temperature,35.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical bottom storage temperature,2020.0
central water pit storage,FOM,0.2544,%/year,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2020.0
central water pit storage,FOM,0.2652,%/year,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2020.0
central water pit storage,Top storage temperature,90.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical max. storage temperature,2020.0
central water pit storage,energy to power ratio,22.5,h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Ratio between energy storage and input capacity,2020.0
central water pit storage,investment,0.9826,EUR/kWh Capacity,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2020.0
central water pit storage,investment,0.9427,EUR/kWh Capacity,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2020.0
central water pit storage,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Technical lifetime,2020.0
central water pit storage,standing losses,0.0078,%/hour,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Energy losses during storage,2020.0
central water tank charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0
Expand Down
4 changes: 2 additions & 2 deletions outputs/costs_2050.csv
Original file line number Diff line number Diff line change
Expand Up @@ -825,10 +825,10 @@ central solid biomass CHP powerboost CC,lifetime,25.0,years,"Danish Energy Agenc
central water pit charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0
central water pit discharger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2020.0
central water pit storage,Bottom storage temperature,35.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical bottom storage temperature,2020.0
central water pit storage,FOM,0.2544,%/year,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2020.0
central water pit storage,FOM,0.2769,%/year,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2020.0
central water pit storage,Top storage temperature,90.0,⁰C,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Typical max. storage temperature,2020.0
central water pit storage,energy to power ratio,22.5,h,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Ratio between energy storage and input capacity,2020.0
central water pit storage,investment,0.9826,EUR/kWh Capacity,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2020.0
central water pit storage,investment,0.9029,EUR/kWh Capacity,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2020.0
central water pit storage,lifetime,30.0,years,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Technical lifetime,2020.0
central water pit storage,standing losses,0.0078,%/hour,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Energy losses during storage,2020.0
central water tank charger,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2020.0
Expand Down
6 changes: 5 additions & 1 deletion scripts/compile_cost_assumptions.py
Original file line number Diff line number Diff line change
Expand Up @@ -189,7 +189,7 @@
"direct firing solid fuels CC": "H:I",
"decentral ground-sourced heat pump": "I:J",
"decentral air-sourced heat pump": "I:J",
"central water pit storage": "J:K",
"central water pit storage": "I:L",
"central water tank storage": "J:K",
"decentral water tank storage": "J:K",
"fuel cell": "I:J",
Expand Down Expand Up @@ -670,6 +670,10 @@ def get_data_DEA(
"gas storage",
]:
usecols = "B:F"
elif tech_name in [
"central water pit storage",
]:
usecols = "B:H"
else:
usecols = "B:G"