5 changes: 5 additions & 0 deletions CHANGELOG.rst
Original file line number Diff line number Diff line change
Expand Up @@ -2,6 +2,11 @@
Changelog for package dynamixel_hardware_interface
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^

1.4.1 (2025-03-31)
------------------
* Modified the Model File
* Contributors: Wonho Yun

1.4.0 (2025-03-20)
------------------
* Added Torque Constant Parameter to DXL Model Files
Expand Down
2 changes: 1 addition & 1 deletion package.xml
Original file line number Diff line number Diff line change
@@ -1,7 +1,7 @@
<?xml version='1.0' encoding='UTF-8'?>
<package format="3">
<name>dynamixel_hardware_interface</name>
<version>1.4.0</version>
<version>1.4.1</version>
<description>
ROS 2 package providing a hardware interface for controlling Dynamixel motors via the ROS 2 control framework.
</description>
Expand Down
4 changes: 3 additions & 1 deletion param/dxl_model/dynamixel.model
Original file line number Diff line number Diff line change
Expand Up @@ -33,12 +33,14 @@ Number Name
1240 xc330_m288.model
1270 xw430_t333.model
1310 xw540_h260.model
2000 ph42_020_s300.model
4000 ym070_210_m001.model
4020 ym070_210_r051.model
4030 ym070_210_r099.model
4050 ym070_210_a099.model
4120 ym080_230_m001.model
4130 ym080_230_b001.model
4140 ym080_230_r051.model
4150 ym080_230_r099.model
4170 ym080_230_a099.model
35074 rh_p12_rn.model
35074 rh_p12_rn.model
68 changes: 68 additions & 0 deletions param/dxl_model/ph42_020_s300.model
Original file line number Diff line number Diff line change
@@ -0,0 +1,68 @@
[type info]
name value
value_of_zero_radian_position 0
value_of_max_radian_position 303750
value_of_min_radian_position -303750
min_radian -3.14159265
max_radian 3.14159265

[control table]
Address Size Data Name
0 2 Model Number
2 4 Model Information
6 1 Firmware Version
7 1 ID
8 1 Baud Rate
9 1 Return Delay Time
10 1 Drive Mode
11 1 Operating Mode
12 1 Secondary(Shadow) ID
13 1 Protocol Type
20 4 Homing Offset
24 4 Moving Threshold
31 1 Temperature Limit
32 2 Max Voltage Limit
34 2 Min Voltage Limit
36 2 PWM Limit
38 2 Current Limit
40 4 Acceleration Limit
44 4 Velocity Limit
48 4 Max Position Limit
52 4 Min Position Limit
512 1 Torque Enable
513 1 LED Red
514 1 LED Green
515 1 LED Blue
516 1 Status Return Level
517 1 Registered Instruction
518 1 Hardware Error Status
524 2 Velocity I Gain
526 2 Velocity P Gain
528 2 Position D Gain
530 2 Position I Gain
532 2 Position P Gain
536 2 Feedforward 2nd Gain
538 2 Feedforward 1st Gain
546 1 Bus Watchdog
548 2 Goal PWM
550 2 Goal Current
552 4 Goal Velocity
556 4 Profile Acceleration
560 4 Profile Velocity
564 4 Goal Position
568 2 Realtime Tick
570 1 Moving
571 1 Moving Status
572 2 Present PWM
574 2 Present Current
576 4 Present Velocity
580 4 Present Position
584 4 Velocity Trajectory
588 4 Position Trajectory
592 2 Present Input Voltage
594 1 Present Temperature
878 1 Backup Ready
168 2 Indirect Address Write
634 1 Indirect Data Write
350 2 Indirect Address Read
698 1 Indirect Data Read
2 changes: 1 addition & 1 deletion param/dxl_model/xh430_v210.model
Original file line number Diff line number Diff line change
Expand Up @@ -64,4 +64,4 @@ Address Size Data Name
168 2 Indirect Address Write
224 1 Indirect Data Write
578 2 Indirect Address Read
634 1 Indirect Data Read
634 1 Indirect Data Read
6 changes: 3 additions & 3 deletions param/dxl_model/ym070_210_r099.model
Original file line number Diff line number Diff line change
@@ -1,8 +1,8 @@
[type info]
name value
value_of_zero_radian_position 25952256
value_of_max_radian_position 51904511
value_of_min_radian_position 0
value_of_zero_radian_position 0
value_of_max_radian_position 262144
value_of_min_radian_position -262144
min_radian -3.14159265
max_radian 3.14159265

Expand Down
96 changes: 96 additions & 0 deletions param/dxl_model/ym080_230_b001.model
Original file line number Diff line number Diff line change
@@ -0,0 +1,96 @@
[type info]
name value
value_of_zero_radian_position 0
value_of_max_radian_position 262144
value_of_min_radian_position -262144
min_radian -3.14159265
max_radian 3.14159265

[control table]
Address Size Data Name
0 2 Model Number
2 4 Model Information
6 1 Firmware Version
7 1 ID
8 2 Bus Watchdog
10 1 Secondary(Shadow) ID
11 1 Protocol Type
12 1 Baud Rate (Bus)
13 1 Return Delay Time
15 1 Status Return Level
16 1 Registered Instruction
32 1 Drive Mode
33 1 Operating Mode
34 1 Startup Configuration
38 2 Position Limit Threshold
40 4 In-Position Threshold
44 4 Following Error Threshold
48 4 Moving Threshold
52 4 Homing Offset
56 1 Inverter Temperature Limit
57 1 Motor Temperature Limit
60 2 Max Voltage Limit
62 2 Min Voltage Limit
64 2 PWM Limit
66 2 Current Limit
68 4 Acceleration Limit
72 4 Velocity Limit
76 4 Max Position Limit
84 4 Min Position Limit
96 4 Electronic GearRatio Numerator
100 4 Electronic GearRatio Denominator
104 2 Safe Stop Time
106 2 Brake Delay
108 2 Goal Update Delay
110 1 Overexcitation Voltage
111 1 Normal Excitation Voltage
112 2 Overexcitation Time
132 2 Present Velocity LPF Frequency
134 2 Goal Current LPF Frequency
136 2 Position FF LPF Time
138 2 Velocity FF LPF Time
152 1 Controller State
153 1 Error Code
154 1 Error Code History 1
155 1 Error Code History 2
168 1 Error Code History 15
169 1 Error Code History 16
170 1 Hybrid Save
212 4 Velocity I Gain
216 4 Velocity P Gain
220 4 Velocity FF Gain
224 4 Position D Gain
228 4 Position I Gain
232 4 Position P Gain
236 4 Position FF Gain
240 4 Profile Acceleration
244 4 Profile Velocity
248 4 Profile Acceleration Time
252 4 Profile Time
256 2 Indirect Address 1
512 1 Torque Enable
513 1 LED
516 2 PWM Offset
518 2 Current Offset
520 4 Velocity Offset
524 2 Goal PWM
526 2 Goal Current
528 4 Goal Velocity
532 4 Goal Position
541 1 Moving Status
542 2 Realtime Tick
544 2 Present PWM
546 2 Present Current
548 4 Present Velocity
552 4 Present Position
560 4 Position Trajectory
564 4 Velocity Trajectory
568 2 Present Input Voltage
570 1 Present Inverter Temperature
571 1 Present Motor Temperature
634 1 Indirect Data 1
919 1 Backup Ready
256 2 Indirect Address Write
634 1 Indirect Data Write
384 2 Indirect Address Read
698 1 Indirect Data Read
6 changes: 3 additions & 3 deletions param/dxl_model/ym080_230_r099.model
Original file line number Diff line number Diff line change
@@ -1,8 +1,8 @@
[type info]
name value
value_of_zero_radian_position 25952256
value_of_max_radian_position 51904511
value_of_min_radian_position 0
value_of_zero_radian_position 0
value_of_max_radian_position 262144
value_of_min_radian_position -262144
min_radian -3.14159265
max_radian 3.14159265

Expand Down
Loading