181 changes: 108 additions & 73 deletions roseau/load_flow/models/line_parameters.py
Original file line number Diff line number Diff line change
Expand Up @@ -5,7 +5,7 @@
from enum import StrEnum
from importlib import resources
from pathlib import Path
from typing import Final, Literal, NoReturn, Self
from typing import Any, Final, Literal, NoReturn, Self

import numpy as np
import numpy.linalg as nplin
Expand Down Expand Up @@ -908,6 +908,75 @@ def from_coiffier_model(cls, name: str, nb_phases: int = 3, id: Id | None = None
#
# Constructors from other software
#
@classmethod
def _parse_power_factory_params(
cls,
id,
inom: float | Q_[float] | None,
cohl: Literal[0, "Cable", 1, "OHL"],
conductor: Literal["Al", "Cu", "Ad", "As", "Ds"] | None,
insulation: Literal[0, "PVC", 1, "XLPE", 2, "Mineral", 3, "Paper", 4, "EPR"] | None,
section: float | Q_[float] | None,
) -> dict[str, Any]:
cohl_norm = str(cohl).upper()
if cohl_norm == "CABLE" or cohl_norm == "0":
line_type = LineType.UNDERGROUND
elif cohl_norm == "OHL" or cohl_norm == "1":
line_type = LineType.OVERHEAD
else:
msg = f"Expected cohl='Cable' or 'OHL', got {cohl!r} for line parameters {id!r}."
logger.error(msg)
raise RoseauLoadFlowException(msg=msg, code=RoseauLoadFlowExceptionCode.BAD_LINE_TYPE)

mlei_norm = conductor.upper() if conductor is not None else None
if mlei_norm is None:
material = None
elif mlei_norm in ("AL", "ALUMINIUM", "ALUMINUM"):
material = Material.AL
elif mlei_norm in ("CU", "COPPER"):
material = Material.CU
elif mlei_norm in ("AD", "ALDREY"):
material = Material.AM
elif mlei_norm in ("AS", "ALUMINIUM-STEEL", "ALUMINUM-STEEL"):
material = Material.AA
elif mlei_norm in ("DS", "ALDREY-STEEL"):
material = Material.LA
else:
msg = f"Expected conductor='Al', 'Cu', 'Ad', 'As' or 'Ds', got {conductor!r} for line parameters {id!r}."
logger.error(msg)
raise RoseauLoadFlowException(msg=msg, code=RoseauLoadFlowExceptionCode.BAD_MATERIAL)

imiso_norm = str(insulation).upper() if insulation is not None else None
if imiso_norm is None:
insulator = None
elif imiso_norm == "PVC" or imiso_norm == "0":
insulator = Insulator.PVC
elif imiso_norm == "XLPE" or imiso_norm == "1":
insulator = Insulator.XLPE
elif imiso_norm == "MINERAL" or imiso_norm == "2":
insulator = Insulator.NONE # not supported yet
elif imiso_norm == "PAPER" or imiso_norm == "3":
insulator = Insulator.IP
elif imiso_norm == "EPR" or imiso_norm == "4":
insulator = Insulator.EPR
else:
msg = (
f"Expected insulation='PVC', 'XLPE', 'MINERAL', 'PAPER' or 'EPR', got {insulation!r} "
f"for line parameters {id!r}."
)
logger.error(msg)
raise RoseauLoadFlowException(msg=msg, code=RoseauLoadFlowExceptionCode.BAD_INSULATOR)

ampacity = inom * 1e3 if inom is not None else None

return {
"line_type": line_type,
"material": material,
"insulator": insulator,
"section": section,
"ampacity": ampacity,
}

@classmethod
@ureg_wraps(
None,
Expand Down Expand Up @@ -935,7 +1004,7 @@ def from_coiffier_model(cls, name: str, nb_phases: int = 3, id: Id | None = None
"mm²",
),
)
def from_power_factory( # noqa: C901
def from_power_factory(
cls,
id: Id,
*,
Expand Down Expand Up @@ -1048,56 +1117,9 @@ def from_power_factory( # noqa: C901
logger.error(msg)
raise RoseauLoadFlowException(msg=msg, code=RoseauLoadFlowExceptionCode.BAD_PHASE)

cohl_norm = str(cohl).upper()
if cohl_norm == "CABLE" or cohl_norm == "0":
line_type = LineType.UNDERGROUND
elif cohl_norm == "OHL" or cohl_norm == "1":
line_type = LineType.OVERHEAD
else:
msg = f"Expected cohl='Cable' or 'OHL', got {cohl!r} for line parameters {id!r}."
logger.error(msg)
raise RoseauLoadFlowException(msg=msg, code=RoseauLoadFlowExceptionCode.BAD_LINE_TYPE)

mlei_norm = conductor.upper() if conductor is not None else None
if mlei_norm is None:
material = None
elif mlei_norm in ("AL", "ALUMINIUM", "ALUMINUM"):
material = Material.AL
elif mlei_norm in ("CU", "COPPER"):
material = Material.CU
elif mlei_norm in ("AD", "ALDREY"):
material = Material.AM
elif mlei_norm in ("AS", "ALUMINIUM-STEEL", "ALUMINUM-STEEL"):
material = Material.AA
elif mlei_norm in ("DS", "ALDREY-STEEL"):
material = Material.LA
else:
msg = f"Expected conductor='Al', 'Cu', 'Ad', 'As' or 'Ds', got {conductor!r} for line parameters {id!r}."
logger.error(msg)
raise RoseauLoadFlowException(msg=msg, code=RoseauLoadFlowExceptionCode.BAD_MATERIAL)

imiso_norm = str(insulation).upper() if insulation is not None else None
if imiso_norm is None:
insulator = None
elif imiso_norm == "PVC" or imiso_norm == "0":
insulator = Insulator.PVC
elif imiso_norm == "XLPE" or imiso_norm == "1":
insulator = Insulator.XLPE
elif imiso_norm == "MINERAL" or imiso_norm == "2":
insulator = Insulator.NONE # not supported yet
elif imiso_norm == "PAPER" or imiso_norm == "3":
insulator = Insulator.IP
elif imiso_norm == "EPR" or imiso_norm == "4":
insulator = Insulator.EPR
else:
msg = (
f"Expected insulation='PVC', 'XLPE', 'MINERAL', 'PAPER' or 'EPR', got {insulation!r} "
f"for line parameters {id!r}."
)
logger.error(msg)
raise RoseauLoadFlowException(msg=msg, code=RoseauLoadFlowExceptionCode.BAD_INSULATOR)

ampacities = inom * 1e3 if inom is not None else None
params = cls._parse_power_factory_params(
id=id, inom=inom, cohl=cohl, conductor=conductor, insulation=insulation, section=section
)

z_line, y_shunt = cls._sym_to_zy_simple(
n=nphase, z0=r0 + 1j * x0, z1=r1 + 1j * x1, y0=1j * b0 * 1e-6, y1=1j * b1 * 1e-6
Expand All @@ -1119,14 +1141,41 @@ def from_power_factory( # noqa: C901
id=id,
z_line=z_line,
y_shunt=y_shunt,
ampacities=ampacities,
line_type=line_type,
materials=material,
insulators=insulator,
sections=section,
ampacities=params["ampacity"],
line_type=params["line_type"],
materials=params["material"],
insulators=params["insulator"],
sections=params["section"],
)
return obj

@classmethod
def _parse_open_dss_params(
cls,
id: Id,
normamps: FloatScalarOrArrayLike1D | None = None,
linetype: str | None = None,
) -> dict[str, Any]:
# Convert OpenDSS line type to RLF line type
if linetype is None:
line_type = None
else:
line_type_upper = linetype.upper()
if line_type_upper == "OH":
line_type = LineType.OVERHEAD
elif line_type_upper == "UG":
line_type = LineType.UNDERGROUND
else:
# TODO other line types
# ['OH', 'UG', 'UG_TS', 'UG_CN', 'SWT_LDBRK', 'SWT_FUSE', 'SWT_SECT',
# 'SWT_REC', 'SWT_DISC', 'SWT_BRK', 'SWT_ELBOW', 'BUSBAR']
logger.warning(f"Line type {linetype} from OpenDSS is not supported, it is ignored.")
line_type = None
return {
"line_type": line_type,
"ampacities": normamps,
}

@classmethod
@ureg_wraps(None, (None, None, None, "ohm/km", "ohm/km", "ohm/km", "ohm/km", "nF/km", "nF/km", "Hz", "A", None))
def from_open_dss(
Expand Down Expand Up @@ -1237,26 +1286,12 @@ def from_open_dss(
z, yc = cls._sym_to_zy_simple(n=n_cond, z0=z0, y0=yc0, z1=z1, y1=yc1)
cls._check_z_line_matrix(id=id, z_line=z)

# Convert OpenDSS line type to RLF line type
if linetype is None:
line_type = None
else:
line_type_upper = linetype.upper()
if line_type_upper == "OH":
line_type = LineType.OVERHEAD
elif line_type_upper == "UG":
line_type = LineType.UNDERGROUND
else:
# TODO other line types
# ['OH', 'UG', 'UG_TS', 'UG_CN', 'SWT_LDBRK', 'SWT_FUSE', 'SWT_SECT',
# 'SWT_REC', 'SWT_DISC', 'SWT_BRK', 'SWT_ELBOW', 'BUSBAR']
logger.warning(f"Line type {linetype} from OpenDSS is not supported, it is ignored.")
line_type = None
params = cls._parse_open_dss_params(id=id, normamps=normamps, linetype=linetype)

# Create the RLF line parameters with off-diagonal resistance allowed
with warnings.catch_warnings():
warnings.filterwarnings(action="ignore", message=r".* off-diagonal elements ", category=UserWarning)
obj = cls(id=id, z_line=z, y_shunt=yc, ampacities=normamps, line_type=line_type)
obj = cls(id=id, z_line=z, y_shunt=yc, ampacities=params["ampacities"], line_type=params["line_type"])
return obj

#
Expand Down
Loading